ANUNCIAR
1SBE121111R0620 ABB Contact. ESB20-20N-06 2NA 230AC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBE121111R0620 ABB Contact. ESB20-20N-06 2NA 230AC/DC

1SBE121111R0620

ABB

Contact. ESB20-20N-06 2NA 230AC/DC

ESB20-20N-06 Installation Contactor (NO) 20 A - 2 NO - 0 NC - 230 V - Control Circuit DC

More details


Devices for distribution board-/surface mounting > Installation contactor for distribution board

Other modular devices

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $68.45
Unit price: $68.45
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85365080
Popular Downloads
EPLAN Data9AAC404715_EPLAN
Data Sheet, Technical Information2CDC103051C0201
Instructions and Manuals2CDC103043M6801
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width18 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.14 kg
Dimension Diagram1SBB505186D3001
Technical
Number of Main Contacts NO2
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles2P
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC/EN 61095
IEC 60335-2-40 A2L
Rated Operational VoltageMain Circuit 220 V DC
Main Circuit 250 V AC
Rated Frequency (f)Control Circuit DC
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit 400 Hz
Main Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)(NO) 20 A
Rated Operational Current AC-3 (Ie)(230 V) Single Phase, NO 9 A
Rated Operational Current AC-7a (Ie)(NO) 20 A
Rated Operational Current AC-7b (Ie)(230 V) Single Phase, NO 9 A
Rated Operational Power AC-1 (Pe)(230 V) Single Phase, NO 4.6 kW
Rated Operational Power AC-3 (Pe)(230 V) Single Phase, NO 1.3 kW
Rated Operational Power AC-7a (Pe)(230 V) Single Phase, NO 4.6 kW
Rated Operational Power AC-7b (Pe)(230 V) Single Phase, NO 1.3 kW
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui)400 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Electrical DurabilityAC-1 (NO) 150000 cycle
AC-3 (NO) 150000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 150000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical DurabilityNr. Operations 1000000 cycle
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)230 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 2.5 V·A
Average Holding Value DC 2.5 W
Average Pull-in Value 50 Hz 2.5 V·A
Average Pull-in Value 60 Hz 2.5 V·A
Average Pull-in Value DC 2.5 W
Power Lossat Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible with Ferrule 1x 1 ... 6 mm²
Flexible with Ferrule 2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 6 mm²
Flexible with Insulated Ferrule 2x 1 ... 1.5 mm²
Flexible 1x 1 ... 6 mm²
Flexible 2x 1 ... 4 mm²
Rigid 1x 1 ... 10 mm²
Rigid 2x 1 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.75 ... 2.5 mm²
Wire Stripping LengthControl Circuit 7 mm
Main Circuit 10 mm
Degree of ProtectionIP20
Recommended Screw DriverControl Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening TorqueControl Circuit 0.9 N·m
Main Circuit 1.2 N·m
Terminal TypeScrew Terminals
Width in Number of Modular Spacings1.0
Product NameInstallation Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 240 V AC
General Use Rating UL/CSA(acc. to UL 240 V) 20 A
Horsepower Rating UL/CSA(220 ... 240 V AC) Single Phase, NO 1 Hp
Connecting Capacity Main Circuit UL/CSASolid 14-8 AWG
Stranded 14-8 AWG
Connecting Capacity Control Circuit UL/CSASolid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSAControl Circuit 8 in·lb
Main Circuit 11 in·lb
Full Load Amps Motor Use(220 ... 240 V AC) Single Phase, NO 8 A
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIPcb871545-f769-46c0-8d09-61cd7b5ae23d Bulgaria
Simplified SCIP0c9cf22f-869a-4c13-b6ac-ce896ba4d3d7 Germany
0d28a6c6-7112-4222-9918-414e5ce2c3db Hungary
29feb08d-c2d0-426d-a7e3-d973e734f760 Sweden
2c9d8d58-41df-44f1-a60d-b6cb96f13bbb Spain
336cb6ea-cb4e-4f90-a434-191a0d32c546 Poland
37bd6088-90fa-406d-b9b5-2b815b487f95 Poland
3a6138ee-acdd-4921-8bfd-a62e8ba730da Croatia
4096d3e5-81d2-4795-b449-b3d1239ad399 Norway
4466e6b2-f26b-476a-bee2-44c9ec2d98c8 Netherlands
5b9d1a46-93a6-4f12-9328-620bcf3c5f16 France
5ffd8553-2280-4091-8ce9-381d9cba949a Belgium
627f64fe-82ef-4dbf-bea8-f60ee646d9cf Germany
64a1844c-26ba-4dd2-8999-8ba4bf247aa6 Greece
79c99109-3181-4dca-9548-ee0076277780 Estonia
79dca0bf-13cc-4cef-8a7c-0626f56c0cdd Finland
8bb6ff21-07aa-4e15-ad75-e790b92637ec Germany
9b0fda5a-e83c-4450-9bc6-f9906a1ccee4 Portugal
9c65aa8f-41d6-44cd-b9a5-44f396d274ea Germany
9f7003cb-b554-4505-9aad-bc382aa14009 Germany
a177d171-9628-4d40-9188-a04949a5b6a5 Italy
ad7377e8-8776-4c68-986a-06b27e86532d Denmark
c9c49e7f-fa34-46f7-9415-be6d8d0669c6 Hungary
cc9f611c-4a3e-4bc5-ab53-d9bdd861ab03 Belgium
cfc86967-b9a3-4b1a-9f19-39f42aeb6521 Czech Republic
da12bd9f-1411-4198-99f4-167611c1e3de Sweden
eaee42d5-b786-4101-9a45-d8a9870ddad1 France
fb37adb0-6e06-48fa-afa6-8796c50a6a2b Poland
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Consumer
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
End Of Life Disassembling Instructions1SBC100156C0268
Environmental Product Declaration - EPD1SAC200416H0001
Certificates and Declarations
A2L Certificate – IEC1SAA920000-4601
ABS Certificate1SAA920000-0101
CB Certificate1SAA920007-2001
CQC CertificateCQC2018010304057353
CQC2018010304057344
Declaration of Conformity - CCC2020980304001370
2020980304001371
Declaration of Conformity - CE1SAD101100-3301
Declaration of Conformity - UKCA1SAD201100-3301
DNV Certificate1SAA920000-0306
EAC Certificate1SAA920003-2701
NF Certificate1SAA920002-1201
RMRS Certificate1SAA920000-0705
UL CertificateE191658-19960301
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width88 mm
Package Level 1 Depth / Length20 mm
Package Level 1 Height71 mm
Package Level 1 Gross Weight0.14 kg
Package Level 1 EAN3471523004641
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC001653 - Installation contactor for distribution board
ETIM 8EC001653 - Installation contactor for distribution board
ETIM 9EC001653 - Installation contactor for distribution board
eClassV11.0 : 27142308
UNSPSC39121529
IDEA Granular Category Code (IGCC)4759 >> Installation contactor for distribution board
E-Number (Finland)3707565
E-Number (Norway)4190231
E-Number (Sweden)3210556

ETIM for 1SBE121111R0620 Modular devices for distribution board/surface mounting (EC001653)
Feature Name Feature Value
Rated operating voltage (EF001435) 220 V
Rated operation current (EF007679) 20 A
Rated excitation voltage (EF008409) 230 V
Voltage type (operating voltage) (EF005294) AC/DC
Voltage type (excitation voltage) (EF005293) AC/DC
Number of contacts as normally open contact (EF008256) 2
Number of contacts as normally closed contact (EF008255) 0
Slider for hand switch (EF005240) No
Width in number of modular spacings (EF002950) 1.0
Built-in depth (EF000218) 58 mm
Additional equipment possible (EF008148) Yes
With day/night function (EF021124) No
Hum-free (EF016334) Yes
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.