Product successfully added to your shopping cart
1SAT142000R1011
ABB
1
Low-voltage industrial components > Motor starter/Motor starter combination
Electronic relays
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85371098 |
| Product Main Type | HF |
| Product Name | Electronic Starter |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC130014M0401 |
| Instructions and Manuals | 2CDC130014M0401 |
| Dimension Diagram | 1SAT100401F0001 |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 99 mm |
| Product Net Depth / Length | 114.5 mm |
| Product Net Weight | 0.206 kg |
| Technical | |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-2 | |
| UL 60947-1 | |
| UL 60947-4-2 | |
| Function | Direct-on-line starter with overload protection |
| Utilization | Motor Protection |
| Rated Operational Voltage | Main Circuit 500 V AC |
| Operational Voltage | Maximum 550 V AC |
| Minimum 42 V AC | |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Rated Control Supply Voltage (Us) | 24 V DC |
| Rated Input Voltage (UIN) | Switching Threshold at Signal <0> -3 ... 9.6 V |
| Switching Threshold at Signal <1> 19.2 ... 30 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Operational Current AC-51 (Ie) | 9 A |
| Rated Operational Current AC-53a (Ie) | 6.5 A |
| Rated Control Supply Current (Is) | 0.04 A |
| Rated Uninterrupted Current (Iu) | 9 A |
| Input Current | 0.003 A |
| Switching Frequency | ≤ 2 Hz |
| 120 starts/min | |
| 7200 starts/h | |
| Rated Operational Power AC-53a (Pe) | 3 kW |
| Overvoltage Category | III |
| Overload Protection | Electronic overload protection |
| Setting Range | 1.5 ... 9.0 A |
| Trip Class | class 10A |
| Number of Poles | 3P |
| Power Loss | Maximum 14.6 W |
| Minimum 1.1 W | |
| Number of Protected Poles | 3 |
| Mechanical Durability | Nr. Operations 10000 cycle |
| Electrical Durability | 30000000 cycle |
| Delay Time (τ) | Off, Maximum, Switched Off via Supply Voltage 500 ms |
| Off, Typical, Switched Off via Control Input Voltage 30 ms | |
| Off, Typical, Switched Off via Supply Voltage 25 ms | |
| Off, Maximum, Switched Off with Pushbutton 3 second [unit of time] | |
| Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time] | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting Position | 1 |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 2 ... 2.5 mm² |
| Flexible 1x 2 ... 2.5 mm² | |
| Rigid 1x 2 ... 2.5 mm² | |
| Recommended Screw Driver | Control Circuit M3 |
| Main Circuit M3 | |
| Terminal Type | Screw Terminals |
| Tightening Torque | Control Circuit 0.5 ... 0.6 N·m |
| Main Circuit 0.5 ... 0.6 N·m | |
| Wire Stripping Length | Control Circuit 8 mm |
| Main Circuit 8 mm | |
| Response Time | Phase Asymmetry 33% 120 second [unit of time] |
| Phase Asymmetry 67% 1.8 second [unit of time] | |
| Phase Failure 1.8 second [unit of time] | |
| Pollution Degree | 2 |
| Phase Loss Sensitive | Yes |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP20 | |
| Short-Circuit Current Rating (SCCR) | (500 V AC, 30 A Class J or CC) 100 kA |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 500 V AC |
| Horsepower Rating UL/CSA | Nominal Switching Performance Full Load (power factor = 0.4) 3 Hp |
| Nominal Switching Performance Full Load (power factor = 0.8) 6.1 Hp | |
| Full Load Amps Motor Use | 6.5 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible with Ferrule 1x 24 ... 14 AWG |
| Flexible 1x 24 ... 14 AWG | |
| Solid 1x 24 ... 14 AWG | |
| Connecting Capacity Control Circuit UL/CSA | Flexible with Ferrule 1x 24 ... 14 AWG |
| Flexible 16-8 AWG | |
| Solid 1x 24 ... 14 AWG | |
| Tightening Torque UL/CSA | Control Circuit 5 ... 7 in·lb |
| Main Circuit 5 ... 7 in·lb | |
| Safety Information | |
| Mean Time to Failure (MTTF) | 43.3 year |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +70 °C |
| Operation Compensated -40 ... + 80 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA983001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006538 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CCC Certificate | 1SAA918005-3802 |
| cUL Certificate | cUL E191658 |
| Declaration of Conformity - CCC | 2020970304003456 |
| Declaration of Conformity - CE | 1SAD938504-0195 |
| Declaration of Conformity - UKCA | 1SAD938501-1195 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 150 mm |
| Package Level 1 Depth / Length | 115 mm |
| Package Level 1 Height | 34 mm |
| Package Level 1 Gross Weight | 0.306 kg |
| Package Level 1 EAN | 4013614515590 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 9 | EC001037 - Motor starter/motor starter combination |
| ETIM 10 | EC001037 - Motor starter/motor starter combination |
| eClass | V11.0 : 27370905 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4727 >> Motor starter controls |
| E-Number (Finland) | 3707542 |
| E-Number (Norway) | 4102018 |
| E-Number (Sweden) | 3210490 |
| Feature Name | Feature Value |
|---|---|
| Type of motor starter (EF009598) | Direct starter |
| With short-circuit release (EF006691) | No |
| Rated control supply voltage AC 50 Hz (EF003978) | 0 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 0 V |
| Rated control supply voltage DC (EF003980) | 24 V |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | 1.50 kW |
| Rated operation power at AC-3, 400 V (EF001364) | 3 kW |
| Rated operation current Ie (EF001443) | 9 A |
| Rated operation current at AC-3, 400 V (EF009602) | 6.5 A |
| Overload release current setting (EF002336) | 1.5 A |
| Ambient temperature, upper operating limit (EF009603) | 80 °C |
| Temperature compensated overload protection (EF009604) | Yes |
| Suitable for rail mounting (EF003972) | Yes |
| With transformer (EF000278) | No |
| Number of command positions (EF001372) | 16 |
| Suitable for emergency stop (EF001433) | No |
| Number of indicator lights (EF001965) | 4 |
| External reset possible (EF003426) | Yes |
| With fuse (EF006693) | No |
| Supporting protocol for TCP/IP (EF003050) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for other bus systems (EF003062) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF ABB Time Relays CT-C CT-S CT-D 2024 EN.pdf | 47 Mbytes |
|
| 1SAT142000R1011 1SAT142000R1011 EN_1SAT142000R1011.pdf | 217 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.