1SAE231111R0104 ABB Contactor ESB25-04N-01 4NC 24AC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SAE231111R0104 ABB Contactor ESB25-04N-01 4NC 24AC/DC

1SAE231111R0104

ABB

Contactor ESB25-04N-01 4NC 24AC/DC

ESB25-04N-01 Installation Contactor (NC) 25 A - 0 NO - 4 NC - 24 V - Control Circuit 400 Hz

More details


Other modular devices

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85365080
Popular Downloads
EPLAN Data9AAC404716_EPLAN
Data Sheet, Technical Information2CDC103051C0201
Instructions and Manuals2CDC103043M6801
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width36 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.245 kg
Technical
Number of Main Contacts NO0
Number of Main Contacts NC4
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational VoltageMain Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f)Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie)(NC) 25 A
Rated Operational Current AC-3 (Ie)(230 V) Single Phase, NC 6 A
Rated Operational Current AC-7a (Ie)(NC) 25 A
Rated Operational Current AC-7b (Ie)(400 V) Three Phase, NC 6 A
Rated Operational Power AC-1 (Pe)(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
Rated Operational Power AC-3 (Pe)(230 V) Single Phase, NC 0.9 kW
(400 V) Three Phase, NC 2.7 kW
Rated Operational Power AC-7a (Pe)(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.25 kW
Rated Operational Power AC-7b (Pe)(230 V) Single Phase, NC 2.7 kW
(400 V) Three Phase, NC 2.7 kW
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui)500 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Electrical DurabilityAC-1 (NC) 50000 cycle
AC-3 (NC) 340000 cycle
AC-7a (NC) 50000 cycle
AC-7b (NC) 340000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical DurabilityNr. Operations 1000000 cycle
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)24 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Lossat Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 7 mm
Main Circuit 10 mm
Degree of ProtectionIP20
Recommended Screw DriverControl Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening TorqueControl Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal TypeScrew Terminals
Width in Number of Modular Spacings2.0
Product NameInstallation Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 480 V AC
General Use Rating UL/CSA(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
Connecting Capacity Main Circuit UL/CSASolid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSASolid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSAControl Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Consumer
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions1SBC100156C0265
Environmental Product Declaration - EPD1SAC200412H0001
Certificates and Declarations
A2L Certificate – IEC1SAA920000-4601
ABS Certificate1SAA920000-0101
CB Certificate1SAA920004-2001
CQC CertificateCQC2017010304993564
CQC2017010304993565
Declaration of Conformity - CCC2020980304001312
2020980304001314
Declaration of Conformity - CE1SAD101100-3301
Declaration of Conformity - UKCA1SAD201100-3301
DNV Certificate1SAA920000-0306
EAC Certificate1SAA920001-2702
RINA Certificate1SAA920000-0801
RMRS Certificate1SAA920000-0705
UL CertificateE191658-19960301
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length39 mm
Package Level 1 Height69.5 mm
Package Level 1 Gross Weight0.245 kg
Package Level 1 EAN4013614523915
Package Level 2 Units48 piece
Package Level 2 Width280 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight12.3 kg
Package Level 2 EAN4013614538315
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC001653 - Installation contactor for distribution board
ETIM 8EC001653 - Installation contactor for distribution board
ETIM 9EC001653 - Installation contactor for distribution board
eClassV11.0 : 27142308
UNSPSC39121529
IDEA Granular Category Code (IGCC)4759 >> Installation contactor for distribution board
E-Number (Finland)3707572
E-Number (Norway)4190252
E-Number (Sweden)3210562

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.