Product successfully added to your shopping cart
1SAE231111R0104
ABB
1
Contactor ESB25-04N-01 4NC 24AC/DC
ESB25-04N-01 Installation Contactor (NC) 25 A - 0 NO - 4 NC - 24 V - Control Circuit 400 Hz
Other modular devices
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Popular Downloads | |
| EPLAN Data | 9AAC404716_EPLAN |
| Data Sheet, Technical Information | 2CDC103051C0201 |
| Instructions and Manuals | 2CDC103043M6801 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 36 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.245 kg |
| Technical | |
| Number of Main Contacts NO | 0 |
| Number of Main Contacts NC | 4 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 61095 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Rated Operational Voltage | Main Circuit 220 V DC |
| Main Circuit 400 V AC | |
| Rated Frequency (f) | Control Circuit 400 Hz |
| Control Circuit 50 Hz | |
| Control Circuit 60 Hz | |
| Control Circuit DC | |
| Main Circuit 50 Hz | |
| Main Circuit 60 Hz | |
| Main Circuit DC | |
| Rated Operational Current AC-1 (Ie) | (NC) 25 A |
| Rated Operational Current AC-3 (Ie) | (230 V) Single Phase, NC 6 A |
| Rated Operational Current AC-7a (Ie) | (NC) 25 A |
| Rated Operational Current AC-7b (Ie) | (400 V) Three Phase, NC 6 A |
| Rated Operational Power AC-1 (Pe) | (230 V) Single Phase, NC 5.8 kW |
| (400 V) Three Phase, NC 17.3 kW | |
| Rated Operational Power AC-3 (Pe) | (230 V) Single Phase, NC 0.9 kW |
| (400 V) Three Phase, NC 2.7 kW | |
| Rated Operational Power AC-7a (Pe) | (230 V) Single Phase, NC 5.8 kW |
| (400 V) Three Phase, NC 17.25 kW | |
| Rated Operational Power AC-7b (Pe) | (230 V) Single Phase, NC 2.7 kW |
| (400 V) Three Phase, NC 2.7 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Electrical Durability | AC-1 (NC) 50000 cycle |
| AC-3 (NC) 340000 cycle | |
| AC-7a (NC) 50000 cycle | |
| AC-7b (NC) 340000 cycle | |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-3) 600 cycles per hour | |
| (AC-7a) 300 cycles per hour | |
| (AC-7b) 600 cycles per hour | |
| Mechanical Durability | Nr. Operations 1000000 cycle |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (Uc) | 24 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 4 V·A |
| Average Holding Value DC 4 W | |
| Average Pull-in Value 50 Hz 4 V·A | |
| Average Pull-in Value 60 Hz 4 V·A | |
| Average Pull-in Value DC 4 W | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 1.5 ... 10 mm² |
| Flexible with Ferrule 2x 1.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | |
| Flexible with Insulated Ferrule 2x 1.5 mm² | |
| Flexible 1x 1.5 ... 10 mm² | |
| Flexible 2x 1.5 ... 4 mm² | |
| Rigid 1x 1.5 ... 10 mm² | |
| Rigid 2x 1.5 ... 4 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1x 1 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.75 ... 1 mm² | |
| Flexible with Insulated Ferrule 1x 1 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² | |
| Flexible 1x 1 ... 4.0 mm² | |
| Flexible 2x 1 ... 2.5 mm² | |
| Rigid 1x 1 ... 4 mm² | |
| Rigid 2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Control Circuit 7 mm |
| Main Circuit 10 mm | |
| Degree of Protection | IP20 |
| Recommended Screw Driver | Control Circuit Pozidriv 1 |
| Main Circuit Pozidriv 1 | |
| Tightening Torque | Control Circuit 0.9 N·m |
| Main Circuit 1 N·m | |
| Terminal Type | Screw Terminals |
| Width in Number of Modular Spacings | 2.0 |
| Product Name | Installation Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 480 V AC |
| General Use Rating UL/CSA | (acc. to UL 240 V) 25 A |
| (acc. to UL 480 V) 25 A | |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Single Phase, NC 1 Hp |
| (220 ... 240 V AC) Three Phase, NC 3 Hp | |
| (440 ... 480 V AC) Single Phase, NC 0.5 Hp | |
| (440 ... 480 V AC) Three Phase, NC 2 Hp | |
| Connecting Capacity Main Circuit UL/CSA | Solid 16-8 AWG |
| Stranded 16-8 AWG | |
| Connecting Capacity Control Circuit UL/CSA | Solid 16-10 AWG |
| Stranded 16-10 AWG | |
| Tightening Torque UL/CSA | Control Circuit 8 in·lb |
| Main Circuit 9 in·lb | |
| Full Load Amps Motor Use | (220 ... 240 V AC) Single Phase, NC 9.6 A |
| (220 ... 240 V AC) Three Phase, NC 9.6 A | |
| (440 ... 480 V AC) Single Phase, NC 7.6 A | |
| (440 ... 480 V AC) Three Phase, NC 7.6 A | |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +55 °C |
| Storage -40 ... +80 °C | |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Consumer |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| UL 2799 Zero Waste To Landfill Validation available | |
| End Of Life Disassembling Instructions | 1SBC100156C0265 |
| Environmental Product Declaration - EPD | 1SAC200412H0001 |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA920000-4601 |
| ABS Certificate | 1SAA920000-0101 |
| CB Certificate | 1SAA920004-2001 |
| CQC Certificate | CQC2017010304993564 |
| CQC2017010304993565 | |
| Declaration of Conformity - CCC | 2020980304001312 |
| 2020980304001314 | |
| Declaration of Conformity - CE | 1SAD101100-3301 |
| Declaration of Conformity - UKCA | 1SAD201100-3301 |
| DNV Certificate | 1SAA920000-0306 |
| EAC Certificate | 1SAA920001-2702 |
| RINA Certificate | 1SAA920000-0801 |
| RMRS Certificate | 1SAA920000-0705 |
| UL Certificate | E191658-19960301 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 92 mm |
| Package Level 1 Depth / Length | 39 mm |
| Package Level 1 Height | 69.5 mm |
| Package Level 1 Gross Weight | 0.245 kg |
| Package Level 1 EAN | 4013614523915 |
| Package Level 2 Units | 48 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 12.3 kg |
| Package Level 2 EAN | 4013614538315 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001653 - Installation contactor for distribution board |
| ETIM 8 | EC001653 - Installation contactor for distribution board |
| ETIM 9 | EC001653 - Installation contactor for distribution board |
| eClass | V11.0 : 27142308 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4759 >> Installation contactor for distribution board |
| E-Number (Finland) | 3707572 |
| E-Number (Norway) | 4190252 |
| E-Number (Sweden) | 3210562 |
| Title: | Size: | Type: |
|---|---|---|
| PDF PROTECTION & SAFETY EN .pdf | 25 Mbytes |
|
| 1SAE231111R0104 EN_1SAE231111R0104.pdf | 89 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.