VAL-CP-N/PE-350-ST 2859699 PHOENIX CONTACT Replacement plug for VAL-CP surge arrester with N-PE spark gap. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-CP-N/PE-350-ST 2859699 PHOENIX CONTACT Replacement plug for VAL-CP surge arrester with N-PE spark gap.

VAL-CP-N/PE-350-ST

2859699

PHOENIX_CONTACT

10

Available

Ship on today

Replacement plug for VAL-CP surge arrester with N-PE spark gap.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+$52.29
20+$51.69
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height46.4 mm
Width11.7 mm
Depth56.4 mm
Horizontal pitch0.6 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

Standards/specificationsIEC 61643-11 2011
EN 61643-11 2012
IEC test classificationII
T2
EN typeT2
IEC power supply systemTN
TT
SPD designVoltage-switching type
Mode of protectionN-PE
Mounting typeOn base element
Colorgray/blue
Housing materialPBT-FR
Pollution degree2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions1
Surge protection fault messageoptical

Protective circuit

Nominal voltage UN240 V AC (TN - only N-PE)
240 V AC (TT - only N-PE)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC (N-PE)264 V AC
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (N-PE)20 kA
Maximum discharge current Imax (8/20) µs (N-PE)40 kA
Follow current interrupt rating Ifi (N-PE)100 A (264 V AC)
Voltage protection level Up (N-PE)≤ 1.5 kV
Residual voltage Ures (N-PE)≤ 0.5 kV (at In)
≤ 0.5 kV (at 10 kA)
≤ 0.5 kV (at 5 kA)
≤ 0.5 kV (at 4 kA)
≤ 0.5 kV (at 2 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs (N-PE)≤ 1.5 kV
TOV behavior at UT (N-PE)1200 V AC (200 ms / withstand mode)
Response time tA (N-PE)≤ 100 ns

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (N-G)264 V AC
Mode of protectionN-G
Power distribution system1
Nominal frequency50/60 Hz
Measured limiting voltage MLV (N-G)950 V
Nominal discharge current In (N-G)20 kA
Follow current (N-G)200 A (264 V AC)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2859699-VAL-CP-N/PE-350-STEnglish118 KbytesPHOENIX CONTACT-2859699-VAL-CP-N/PE-350-ST

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or