Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for transceiver systems - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$47.82
5+$44.27
10+$43.20
14+$42.75
19+$42.41
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height107 mm
Width63 mm
Depth78 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 75 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C

General

Housing materialPA 6
Flammability rating according to UL 94V-0
Standards for cearances and creepage distancesEN 60664-1
EN 61643-11
EN 61643-1
Total surge current (8/20) µs5 kA
Colorjet black RAL 9005
For country-specific use inD, A, NL, E, S, FIN, TR
Mounting typePlugging into the mains socket
TypeAttachment plug
Direction of actionL/N-PE & Signal Line-Shield-Earth Ground

Protective circuit, power supply

IEC test classificationIII
T3
EN typeT3
Nominal voltage UN230 V AC
Arrester rated voltage UC (L-N)275 V AC
Arrester rated voltage UC (L-PE)360 V AC
Arrester rated voltage UC (N-PE)360 V AC
Nominal frequency fN50 Hz (60 Hz)
Standby power consumption PC≤ 1 VA
Residual current IPE≤ 5 µA
Nominal discharge current In (8/20) µs3 kA (> 5x)
Combination wave UOC4 kV
Energy absorption symmetrical140 J (L-N)
Enery absorption, asymmetrical220 J (L(N)-PE)
Voltage protection level Up (L-N)≤ 1.2 kV
Voltage protection level Up (L-PE)≤ 1.5 kV
Voltage protection level Up (N-PE)≤ 1.5 kV
Total surge current (8/20) µs5 kA
Response time (L-N)≤ 25 ns
Response time (L-PE)≤ 100 ns
Response time (N-PE)≤ 100 ns
Surge protection fault messageoptical
Max. required back-up fuse16 A AC (gG / B / C)

Connection (protective circuit, power supply)

Connection methodGrounding plug/socket
Connection type INGrounding plug
Connection type OUTGrounding socket

Protective circuit, information technology

Arrester rated voltage UC72 V DC
50 V AC
Arrester rated voltage UC (Core-Shield)72 V DC
50 V AC
Arrester rated voltage UC (Shield-Earth)380 V DC
Nominal current IN1.5 A (25 °C)
Operating effective current IC at UC≤ 1 µA
Residual current IPE≤ 1 µA
Insulation resistance Riso≥ 70 MΩ
≥ 70 MΩ
Nominal discharge current In (8/20) µs (Core-Earth)2.5 kA
Nominal discharge current In (8/20) µs (Core-Shield)2.5 kA
Nominal discharge current In (8/20) µs (Shield-Earth)5 kA
Voltage protection level Up (core-shield)≤ 700 V (C2 - 2 kA)
Voltage protection level Up (shield-ground)≤ 1.2 kV (C2 - 5 kA)
Response time tA (Core-Shield)≤ 100 ns
Response time tA (Shield-Earth)≤ 100 ns
Input attenuation aE, asym.typ. 0.3 dB (≤ 2.4 GHz /75 Ω)
Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm systemtyp. 2.5 GHz
Frequency range0 Hz ... 2400 MHz
Capacity asymmetrical (shield)typ. 10 pF
Nominal pulse current ian (10/1000) µs, asym. (shield)120 A
Residual voltage at In (conductor-shield)≤ 40 V
Residual voltage at In (shield-ground)≤ 50 V
Impulse durability (conductor-shield)C2 - 4 kV/2 kA
C3 - 7.5 kV/100 A
Impulse durability (shield-ground)C2 - 10 kV / 5 kA
C3 - 7.5 kV/100 A
D1 - 1 kA
Alternating current carrying capacity (conductor-shield)5 A - 1 s
Alternating current carrying capacity (shield-ground)10 A - 1 s
Pulse reset time (conductor-shield)Cannot be measured

Power supply, general

Connection methodF connector
Connection type INF connector, female
Connection type OUTF connector, female

Connection, equipotential bonding, information technology

Connection methodVia protective contact plug

Standards (protective circuit, information technology)

IEC test classificationC2
C3
D1

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2882284-MNT-TV-SAT DEnglish373 KbytesPHOENIX CONTACT-2882284-MNT-TV-SAT D