TRIO-PS-2G/3AC/24DC/20 2903155 PHOENIX CONTACT Primary-switched TRIO POWER power supply with push-in connect.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

TRIO-PS-2G/3AC/24DC/20 2903155 PHOENIX CONTACT Primary-switched TRIO POWER power supply with push-in connect..

TRIO-PS-2G/3AC/24DC/20

2903155

PHOENIX_CONTACT

Available

Ship on today

Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/20 A

More details


Power Supplies

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Power. Power Supply - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$294.58
2+$287.99
3+$285.41
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

TRIO POWER power supplies with standard functionality

The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.

Dimensions

Width65 mm
Height130 mm
Depth160 mm

Input data

Nominal input voltage range3x 400 V AC ... 500 V AC -20 % ... +15 %
2x 400 V AC ... 500 V AC -10 % ... +15 %
Input voltage range3x 320 V AC ... 575 V AC
2x 360 V AC ... 575 V AC
AC frequency range50 Hz ... 60 Hz
Discharge current to PE≤ 3.5 mA
Inrush surge current≤ 22 A (typical)
Power failure bypass> 10 ms (400 V AC)
> 20 ms (500 V AC)
Input fuse3.15 A (internal (device protection), slow-blow)
Choice of suitable circuit breakers6 A ... 16 A (Characteristics B, C, D, K)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current20 A
Dynamic BOOST30 A (5 s)
Derating> 60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesYes
Control deviation< 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple≤ 20 mVPP
Output power480 W
Typical response time< 1 s
Maximum power dissipation in no-load condition< 1.2 W

General

Net weight1.5 kg
Efficiency> 93 % (at 400 V AC and nominal values)
Insulation voltage input/output4 kV AC (type test)
1.5 kV AC (routine test)
Protection classI (in closed control cabinet)
MTBF (IEC 61709, SN 29500)> 1800000 h (25 °C)
> 1100000 h (40°C)
> 510000 h (60°C)
Mounting positionOn horizontal and vertical DIN rail
Assembly instructionsCan be aligned: Horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm

Connection data, input

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Connection data, output

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.10 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.6 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.8
Stripping length15 mm

Signaling

Signalization designationDC OK
Output nameLED status indicator
Maximum switching voltage30 V AC/DC
Continuous load current100 mA
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2903155-TRIO-PS-2G/3AC/24DC/20English125 KbytesPHOENIX CONTACT-2903155-TRIO-PS-2G/3AC/24DC/20

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or