PLC-RSC- 24DC/ 1IC/ACT
2967604
PHOENIX_CONTACT
1
Relay Module
INTERFACE Components (IF)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2967604 |
---|---|
Packing unit | 10 pc |
Catalog page | Page 386 (C-5-2017) |
GTIN | 4017918169794 |
Weight per Piece (excluding packing) | 67.980 g |
Custom tariff number | 85364900 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|---|
Note | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. |
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules | |
The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. | |
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
Ambient temperature (operation) | -40 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 2000 m |
Nominal input voltage UN | 24 V DC |
---|---|
Typical input current at UN | 18 mA |
Typical response time | 8 ms |
Typical release time | 10 ms |
Coil voltage | 24 V DC |
Protective circuit | Reverse polarity protection Polarity protection diode |
Free-wheeling diode Damping diode | |
Operating voltage display | Yellow LED |
Power dissipation for nominal condition | 0.43 W |
Contact type | 1 N/O contact |
---|---|
Type of switch contact | Single contact |
Contact material | AgSnO2 |
Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum switching voltage | 12 V (at 100 mA) |
Min. switching current | 100 mA (at 12 V DC) |
Maximum inrush current | 80 A (20 ms) |
130 A (peak, at capacitive load, 230 V AC, 24 μF) | |
Limiting continuous current | 6 A |
10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged) | |
Interrupting rating (ohmic load) max. | 144 W (at 24 V DC) |
58 W (at 48 V DC) | |
48 W (at 60 V DC) | |
50 W (at 110 V DC) | |
80 W (at 220 V DC) | |
85 W (for 250 V DC) | |
1500 VA (for 250 V AC) | |
Interrupting rating (ohmic load) max. bridged | 240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) | |
Switching capacity min. | 1200 mW |
Switching capacity | 2 A (at 24 V, DC13) |
0.2 A (at 110 V, DC13) | |
0.2 A (at 250 V, DC13) | |
6 A (at 24 V, AC15) | |
6 A (at 120 V, AC15) | |
6 A (at 250 V, AC15) |
Connection name | Coil side |
---|---|
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
0.2 mm² ... 2.5 mm² () | |
2x 0.5 mm² ... 1.5 mm² () | |
Conductor cross section AWG | 26 ... 14 |
Connection name | Contact side |
---|---|
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
0.2 mm² ... 2.5 mm² () | |
2x 0.5 mm² ... 1.5 mm² () | |
Conductor cross section AWG | 26 ... 14 |
Note | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. |
---|---|
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules | |
The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. | |
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. | |
Test voltage relay winding/relay contact | 4 kV AC (50 Hz, 1 min.) |
Operating mode | 100% operating factor |
Degree of protection | RT II (Relay) |
IP20 (Relay base) | |
Mechanical service life | 3x 107cycles |
Mounting position | any |
Assembly instructions | In rows with zero spacing |
Net weight (SAP) | 67.98 g |
Connection in acc. with standard | CUL |
---|---|
Designation | Standards/regulations |
Standards/regulations | EN 50178 |
EN 61810-1 | |
Rated insulation voltage | 250 V AC |
Rated surge voltage | 6 kV |
Insulation | Safe isolation, reinforced insulation |
Degree of pollution | 2 |
Overvoltage category | III |
Flammability rating according to UL 94 | V0 |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2967604-PLC-RSC- 24DC/ 1IC/ACT | 160 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.