PLC-RSC- 24DC/ 1IC/ACT 2967604 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-RSC- 24DC/ 1IC/ACT 2967604 PHOENIX CONTACT Relay Module

PLC-RSC- 24DC/ 1IC/ACT

2967604

PHOENIX_CONTACT

Relay Module

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $26.69
Unit price: $26.69

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2967604
Packing unit10 pc
Catalog pagePage 386 (C-5-2017)
GTIN4017918169794
Weight per Piece (excluding packing)67.980 g
Custom tariff number85364900
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
NoteSeparating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules
The PLC-ATP separating plate is required at the start and end of every PLC terminal strip.
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.

Dimensions

Width14 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m

Coil side

Nominal input voltage UN24 V DC
Typical input current at UN18 mA
Typical response time8 ms
Typical release time10 ms
Coil voltage24 V DC
Protective circuitReverse polarity protection Polarity protection diode
Free-wheeling diode Damping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.43 W

Contact side

Contact type1 N/O contact
Type of switch contactSingle contact
Contact materialAgSnO2
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage12 V (at 100 mA)
Min. switching current100 mA (at 12 V DC)
Maximum inrush current80 A (20 ms)
130 A (peak, at capacitive load, 230 V AC, 24 μF)
Limiting continuous current6 A
10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged)
Interrupting rating (ohmic load) max.144 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
85 W (for 250 V DC)
1500 VA (for 250 V AC)
Interrupting rating (ohmic load) max. bridged240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.)
2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.)
Switching capacity min.1200 mW
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
6 A (at 24 V, AC15)
6 A (at 120 V, AC15)
6 A (at 250 V, AC15)

Connection data 1

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² ()
2x 0.5 mm² ... 1.5 mm² ()
Conductor cross section AWG26 ... 14

Connection data 2

Connection nameContact side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² ()
2x 0.5 mm² ... 1.5 mm² ()
Conductor cross section AWG26 ... 14

General

NoteSeparating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules
The PLC-ATP separating plate is required at the start and end of every PLC terminal strip.
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.
Test voltage relay winding/relay contact4 kV AC (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionRT II (Relay)
IP20 (Relay base)
Mechanical service life3x 107cycles
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)67.98 g

Standards and Regulations

Connection in acc. with standardCUL
DesignationStandards/regulations
Standards/regulationsEN 50178
EN 61810-1
Rated insulation voltage250 V AC
Rated surge voltage6 kV
InsulationSafe isolation, reinforced insulation
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V0

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Articles in set

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.