Key Commercial Data

Orderkey2700977
Packing unit1 pc
Catalog pagePage 83 (C-6-2017)
GTIN4046356665537
Weight per Piece (excluding packing)350.000 g
Custom tariff number85371091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width85 mm
Height119.8 mm
Depth71.5 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)5g

Control system

Engineering toolPC WORX
PC WORX EXPRESS
Programming languages supportedProgramming in acc. with IEC 61131-3
Diagnostics toolDIAG+
Configuration toolConfig+ Version 1.01 or later

IEC 61131 runtime system

Engineering toolPC WORX
PC WORX EXPRESS
Program memory512 kByte
Mass storage512 kByte
Retentive mass storage48 kByte (NVRAM)
Number of control tasks8
Realtime clockYes

Fieldbus function

Amount of process datamax. 4096 Bit (INTERBUS)
Number of supported devicesmax. 128
Number of local bus devices that can be connectedmax. 63 (observe current consumption)
Number of devices with parameter channelmax. 16
Number of supported branch terminals with remote bus branchmax. 3

Data interfaces

InterfaceEthernet 10Base-T/100Base-TX
Number1
Connection methodRJ45 socket
Transmission speed10/100 Mbps
InterfaceINTERBUS local bus (master)
Number1
Connection methodInline data jumper
Transmission speed500 kBaud / 2 MBaud (can be switched)
InterfaceGSM / GPRS
Number1
Connection methodSIM card, SMA antenna connection
Interface descriptionGSM / GPRS

Direct I/Os

Input nameDigital inputs
Number of inputs16
Connection methodInline potential distributor
Connection technology2, 3, 4-wire
Description of the inputEN 61131-2 type 1 NPN/PNP
Output nameDigital outputs
Number of outputs4
Connection methodSpring-cage connection
Connection technology2, 3, 4-wire
Maximum output current per channel500 mA

Power supply

Typical current consumption210 mA
Max. current consumption860 mA (360 mA communications power + 500 mA analog voltage supply)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC
Residual ripple± 5 %
Power dissipationmax. 5 W

Mechanical design

Weight285 g
Diagnostics displayNo
Controller redundancyNo
Safety functionNo

General data

ProcessorAltera Nios II 64 MHz

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Interference emissionNoise emission test as per EN 61000-6-4 EN 55011 Class A
Immunity to surgeNoise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
Immunity to burstNoise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
Immunity to EFNoise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to ESDNoise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity to conducted interferenceNoise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Vibration (storage/transport)5g
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)5g

Environmental Product Compliance

REACh SVHC1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
Lead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.