ILC 200 IB-PAC 2862288 PHOENIX CONTACT Inline controller, complete with accessories (connector and labeling .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ILC 200 IB-PAC 2862288 PHOENIX CONTACT Inline controller, complete with accessories (connector and labeling ..

ILC 200 IB-PAC

2862288

PHOENIX_CONTACT

Available

Ship on today

Inline controller, complete with accessories (connector and labeling field). The controller is installed instead of a standard Inline bus coupler. It connects the station to the higher-level INTERBUS network in the same way as a bus coupler

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

With the Inline Control CPU, the Inline station is transformed into a modular compact controller. The Inline controller is installed instead of the standard Inline bus terminal module. Thwe Inline Control connects the station to the higher-level network, just like a bus terminal module.

The integrated control functions can be programmed according to IEC 61131-3. These functions permit distributed and independent control of the Inline installation system. Fast inputs and outputs ensure short response times.

Use of the Inline controller or other Remote Field Controllers permits to set up pre-tested mechanical and electrical units that can be combined as desired to form a complete solution. By combining tested mechanical, electrical, I/O device and control program functional units, planning, installation and startup times are considerably reduced. Systems can also be expanded in a flexible manner by following this principle.

Programming with PC WORX

The Inline controller is programmed with PC WORX automation software. The programs are created using the international IEC 61131-3 standard. They are downloaded either over the INTERBUS interface or over the local RS-232 interface. Programs and configuration data are stored in the integrated flash memory in a non-volatile way. 8 Kbytes of non-volatile (NV)RAM is available for the remanent storage of variables and flags.

Dimensions

Width109.8 mm
Height140.5 mm
Depth71.5 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)0 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C
Permissible humidity (operation)5 % ... 85 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 85 % (non-condensing)
Air pressure (operation)70 kPa ... 108 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above mean sea level)
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)2g, criterion 1 according to IEC 60068-2-6

Control system

Programming toolPC WORX
Diagnostics toolDIAG+ from version 1.14

Mechanical design

Weight320 g
Diagnostics displayNo
Controller redundancyNo

Data interfaces

InterfaceINTERBUS local bus (master)
Connection methodInline data jumper
Transmission speed500 kBaud / 2 MBaud (can be switched)
InterfaceHigher-level INTERBUS remote bus (slave)
Connection methodInline shield connector
InterfaceParameterization/operation/diagnostics
Connection methodRS-232-C, 6-pos. MINI-DIN socket (PS/2)
Transmission speed19200 Baud

Power supply

Power supply connection8-pos. Inline connector
Typical current consumption153 mA (no local bus device connected during idling, bus inactive)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC
Residual ripple±5 %
Power dissipationmax. 3.25 W
Max. total permissible current consumption of all I/O terminal blocksCommunications power (7,5 V DC) ≤ 2 A DC
Analog supply (24 V DC) ≤ 0.5 A

Fieldbus function

Amount of process datamax. 4096 Bit (INTERBUS-Master)
160 Bit (INTERBUS-Slave)
Number of parameter datamax. 8 Byte (configurable)
Number of supported devicesmax. 512
Number of local bus devices that can be connectedmax. 63 (observe current consumption)
Number of devices with parameter channelmax. 62
Number of supported branch terminals with remote bus branchmax. 15

Direct I/Os

Input nameDigital inputs
Number of inputs4
Connection methodInline potential distributor
Description of the inputInterrupt input, fast counter, pulse generator
Output nameDigital outputs
Number of outputs2
Connection method2, 3, 4-wire
Maximum output current per channel500 mA
Without analog inputyes
Without analog outputyes
Without pulse direction outputNo
Number of pulse direction outputs2
Limit frequency20 kHz
Without counter inputNo
Number of inputs4
Input frequency40 kHz

IEC 61131 runtime system

Programming toolPC WORX
Program memorytyp. 384 kByte (32 K instructions (IL))
Mass storage330 kByte
Retentive mass storage8 kByte (NVRAM)
Number of control tasks8

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2862288-ILC 200 IB-PACEnglish127 KbytesPHOENIX CONTACT-2862288-ILC 200 IB-PAC