UT 4-PE/L/HESILED 60 (5X20)
3214322
PHOENIX_CONTACT
50
Fuse modular terminal block
Terminal blocks > Fuse terminal block
Modular TBs
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 3214322 |
---|---|
Packing unit | 50 pc |
Minimum order quantity | 50 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 232 (C-1-2017) |
GTIN | 4046356895675 |
Weight per Piece (excluding packing) | 37.100 g |
Custom tariff number | 85369095 |
Country of origin | PL (Poland) |
Note | The current is determined by the fuse used, the voltage by the selected LED. If the fuse is faulty, the downstream circuit will not be disconnected. |
---|---|
Number of levels | 3 |
Number of connections | 5 |
Nominal cross section | 4 mm² |
Color | black |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Maximum power dissipation for nominal condition | 1.6 W (the value is multiplied when connecting multiple levels) |
Fuse | G / 5 x 20 |
Fuse type | Glass / ceramics / ... |
Rated surge voltage | 6 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Maximum power dissipation | max. 1.6 W (With single arrangement of the fuse terminal block in the event of overload) |
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) | |
max. 4 W (With single arrangement of the fuse terminal block in the event of a short-circuit) | |
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) | |
LED voltage range | 30 V AC ... 60 V AC |
LED current range | 0.4 mA ... 0.86 mA |
Connection in acc. with standard | IEC 60947-7-2/IEC 60947-7-3 |
Maximum load current | 36 A (the current is determined by the fuse used) |
Nominal current IN | 28 A |
Nominal voltage UN | 60 V |
Connection in acc. with standard | IEC 60947-7-2/IEC 60947-7-3 |
Maximum load current (upper level) | 6.3 A (the current is determined by the fuse used) |
Nominal current IN(upper level) | 6.3 A |
Nominal voltage UN | 60 V |
Open side panel | No |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Static insulating material application in cold | -60 °C |
Behavior in fire for rail vehicles (DIN 5510-2) | Test passed |
Flame test method (DIN EN 60695-11-10) | V0 |
Oxygen index (DIN EN ISO 4589-2) | >32 % |
NF F16-101, NF F10-102 Class I | 2 |
NF F16-101, NF F10-102 Class F | 2 |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Note | Please observe the current carrying capacity of the DIN rails. |
---|---|
Conductor cross section solid min. | 0.14 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.14 mm² |
Conductor cross section flexible max. | 6 mm² |
Conductor cross section AWG min. | 26 |
Conductor cross section AWG max. | 10 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 4 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 4 mm² |
Connection method | Screw connection |
Stripping length | 9 mm |
Internal cylindrical gage | A4 |
Screw thread | M3 |
Tightening torque, min | 0.6 Nm |
Tightening torque max | 0.8 Nm |
Connection in acc. with standard | IEC 60947-7-2/IEC 60947-7-3 |
---|---|
IEC 60947-7-2/IEC 60947-7-3 | |
Flammability rating according to UL 94 | V0 |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX TERMINAL BLOCKS EN.pdf | 69 Mbytes | |
PHOENIX CONTACT-3214322-UT 4-PE/L/HESILED 60 (5X20) | 134 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.