UIK 16 BU 3006205 PHOENIX CONTACT Installation terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

UIK 16 BU 3006205 PHOENIX CONTACT Installation terminal block

UIK 16 BU

3006205

PHOENIX_CONTACT

50

Installation terminal block

More details


Modular TBs

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
50+$3.95
100+$3.52
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey3006205
Packing unit50 pc
Catalog pagePage 505 (C-1-2017)
GTIN4017918091422
Weight per Piece (excluding packing)20.600 g
Custom tariff number85369010
Country of originDE (Germany)

General

Number of levels1
Number of connections2
Nominal cross section16 mm²
Colorblue
Insulating materialPA
Flammability rating according to UL 94V2
Maximum load current101 A (with a 2.5 mm² conductor cross section)
Rated surge voltage6 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition2.43 W
Connection in acc. with standardIEC 60947-7-1
Nominal current IN76 A
Maximum load current101 A (with a 2.5 mm² conductor cross section)
Nominal voltage UN400 V
Open side panelYes
Result of surge voltage testTest passed
Surge voltage test setpoint7.3 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint1.89 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed
Result of bending testTest passed
Bending test rotation speed10 rpm
Bending test turns135
Bending test conductor cross section/weight4 mm² / 0.9 kg
16 mm² / 2.9 kg
25 mm² / 4.5 kg
Tensile test resultTest passed
Conductor cross section tensile test4 mm²
Tractive force setpoint60 N
Conductor cross section tensile test16 mm²
Tractive force setpoint100 N
Conductor cross section tensile test25 mm²
Tractive force setpoint135 N
Result of tight fit on supportTest passed
Tight fit on carrierNS 35/NS 32
Setpoint5 N
Result of voltage-drop testTest passed
Requirements, voltage drop≤ 3.2 mV
Result of temperature-rise testTest passed
Short circuit stability resultTest passed
Conductor cross section short circuit testing16 mm²
Short-time current1.92 kA
Conductor cross section short circuit testing25 mm²
Short-time current3 kA
Result of thermal testTest passed
Proof of thermal characteristics (needle flame) effective duration30 s
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width12.2 mm
Length42.5 mm
Height NS 35/7,547 mm
Height NS 35/1554.5 mm
Height NS 3252 mm

Connection data

NoteTerminal point
Conductor cross section solid min.2.5 mm²
Conductor cross section solid max.25 mm²
Conductor cross section flexible min.4 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.12
Conductor cross section AWG max.4
Conductor cross section flexible, with ferrule without plastic sleeve min.1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.16 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.16 mm²
2 conductors with same cross section, solid min.1.5 mm²
2 conductors with same cross section, solid max.6 mm²
2 conductors with same cross section, stranded min.1.5 mm²
2 conductors with same cross section, stranded max.6 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.4 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.75 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.10 mm²
Connection methodScrew connection
Stripping length11 mm
Screw threadM4
Tightening torque, min1.5 Nm
Tightening torque max1.8 Nm

Standards and Regulations

Connection in acc. with standardCSA
IEC 60947-7-1
Flammability rating according to UL 94V2
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.