MACX MCR-EX-SL-IDSI-I 2865405 PHOENIX CONTACT Ex-i output signal conditioner, HART Isolates and sends intrin.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-EX-SL-IDSI-I 2865405 PHOENIX CONTACT Ex-i output signal conditioner, HART Isolates and sends intrin..

MACX MCR-EX-SL-IDSI-I

2865405

PHOENIX_CONTACT

Available

Ship on today

Ex-i output signal conditioner, HART Isolates and sends intrinsically safe 0/4-20 mA signals to a load (I/P converters, control valves, displays) in Ex areas. Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508.

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$227.72
2+$222.27
3+$219.57
4+$218.57
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

Current input signal0 mA ... 20 mA
4 mA ... 20 mA
Input voltage limitation5.4 V (at 20 mA)
Input impedance> 100 kΩ (If there is a line fault)

Output data

Signal outputCurrent output
Current output signal0 mA ... 20 mA (intrinsically safe)
4 mA ... 20 mA (intrinsically safe)
Transmission Behavior1:1 to input signal
Load/output load current output< 800 Ω (at 20 mA)
< 730 Ω (at 22.5 mA)
Output ripple< 20 mVrms

Power supply

Supply voltage range19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
Max. current consumption< 46 mA (at 24 V DC / 20 mA)
Power consumption< 1.1 W (at 24 V DC / 20 mA)

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)< 140 µs (for 4 mA ... 20 mA step)
Status displayGreen LED (supply voltage)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Emitted interferenceEN 61000-6-4
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation1.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage (overvoltage category II, pollution degree 2))
DesignationOutput/input
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationOutput/supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEXEx II (1) G [Ex ia Ga] IIC/IIB
Ex II (1) D [Ex ia Da] IIIC
Ex II 3(1) G Ex nA [ia Ga] IIC/IIB T4 Gc
IECEx[Ex ia Ga] IIC/IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC/IIB T4 Gc
UL, USA / CanadaClass I Div 2; IS for Class I, II, III Div 1

Data communication (bypass)

HART functionYes
Protocols supportedHART

Safety characteristic data

Integrity requirementIEC 61508 - Low demand
Equipment typeType A
Safety Integrity Level (SIL)Up to 2
Safe Failure Fraction (SFF)94.68 %
λSU4.965 x 10-7 (496.5 FIT)
λSD0
λDU2.79 x 10-8 (27.9 FIT)
λDD0
Probability of a hazardous failure on demand (PFDAVG)1.22 x 10-4 (1 year)
6.1 x 10-4 (5 years)
12.2 x 10-4 (10 years)
Diagnostic coverage (DC)DCS = 0%, DCD = 0%
Integrity requirementIEC 61508 - High demand
Equipment typeType A
Safety Integrity Level (SIL)Up to 2
Safe Failure Fraction (SFF)94.68 %
λSU4.965 x 10-7 (496.5 FIT)
λSD0
λDU2.79 x 10-8 (27.9 FIT)
λDD0
Probability of a hazardous failure per hour (PFHD)2,79 x 10-8
Diagnostic coverage (DC)DCS = 0%, DCD = 0%

Safety data

Max. output voltage Uo27.7 V
Max. output current Io92 mA
Max. output power Po633 mW
GroupIIC
Max. external inductivity Lo2 mH
Max. external capacity Co85 nF
GroupIIB
Max. external inductivity Lo4 mH
Max. external capacity Co663 nF
Safety-related maximum voltage Um253 V AC (125 V DC)

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2865405-MACX MCR-EX-SL-IDSI-IEnglish144 KbytesPHOENIX CONTACT-2865405-MACX MCR-EX-SL-IDSI-I