HC-M-02-HS-70/16-MOD-BU 1585715 PHOENIX CONTACT HEAVYCON contact insert module, socket, 2-pos. to 70 A, 16 m.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HC-M-02-HS-70/16-MOD-BU 1585715 PHOENIX CONTACT HEAVYCON contact insert module, socket, 2-pos. to 70 A, 16 m..

HC-M-02-HS-70/16-MOD-BU

1585715

PHOENIX_CONTACT

2

Available

Ship on today

HEAVYCON contact insert module, socket, 2-pos. to 70 A, 16 mm² axial screw connection

More details


Core End Sleeves Cable Crimp

PLUSCON Field cabling - PHOENIX CONTACT

Heavy industrial connectors - PLUSCON heavy - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
2+$29.01
8+$27.19
16+$26.53
22+$26.27
30+$26.03
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Electrical characteristics

NoteFor HEAVYCON HC-B6 to B48 housing, HC-M-MHR... hinged retaining frame required, axial connection for 2.5 mm Allen key
Rated voltage (III/3)1000 V
Rated current70 A
Rated surge voltage8 kV
Number of positions2

Ambient conditions

Ambient temperature (operation)-40 °C ... 125 °C

Mechanical characteristics

Conductor cross section6 mm² ... 16 mm²
Connection cross section AWG8 ... 6
Stripping length of the individual wire11 mm +1
Tightening torque2 Nm (6 mm²)
3 Nm (10 mm²)
4 Nm (16 mm²)
Wire diameter including insulation8.9 mm
Hexagonal socketSW2,5
Insertion/withdrawal cycles≥ 500
Minimum housing height72 mm

General

SeriesHC-M-HS
Number of module slots1
Connection methodAxial screw connection
Flammability rating according to UL 94V0
Pollution degree3
Overvoltage categoryIII
Assembly instructionsUse 2.5 mm Allen wrenches for axial connection. Only for stranded wires. For housing heights h ≥ 52 mm. Plug-in connections may only be operated only when there is no load/voltage.
ConnectionNote regarding axial connection technology: Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructions Before assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.

Material data

Contact materialCopper alloy
Contact surface materialAg
Contact carrier materialPC

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-1585715-HC-M-02-HS-70/16-MOD-BUEnglish120 KbytesPHOENIX CONTACT-1585715-HC-M-02-HS-70/16-MOD-BU

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or