F3SJ-B1985P25 356736 OMRON Security Product, Class IV Basic Hand 1985mm Serial connection View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

F3SJ-B1985P25 356736 OMRON Security Product, Class IV Basic Hand 1985mm Serial connection

F3SJ-B1985P25

356736

OMRON

Available

Ship on today

Security Product, Class IV Basic Hand 1985mm Serial connection

More details


Security Light Curtains

Lightcurtains and area sensors - OMRON

Lightcurtains and area sensors - F3S-B - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



F3SJ-B Safety sensors
Basic type with a combination of performance and functionality
The F3SJ-B-family is a type 4 safety light curtain with an optical resolution of 25 mm. An operation range of up to 7 m and a protective height up to 2,065 mm are provided with no dead zone
• Detection height = sensor height
• Simple hand protection
• Muting function available
• Series connection up to three sets
• Type 4 sensor complying with EN 61496-1 and up to PLe according EN ISO 13849
Ordering information
Application Detection capability Beam gap Operating range Protective height (mm) Order code
Hand protection Dia. 25 mm 20 mm 0.2 to 7 m 185 to 2,065 F3SJ-B P25
Number of beams Protective height (mm)*1
Order code
8 185 F3SJ-B0185P25
10 225 F3SJ-B0225P25
14 305 F3SJ-B0305P25
18 385 F3SJ-B0385P25
22 465 F3SJ-B0465P25
26 545 F3SJ-B0545P25
30 625 F3SJ-B0625P25
34 705 F3SJ-B0705P25
38 785 F3SJ-B0785P25
42 865 F3SJ-B0865P25
46 945 F3SJ-B0945P25
50 1,025 F3SJ-B1025P25
54 1,105 F3SJ-B1105P25
58 1,185 F3SJ-B1185P25
62 1,265 F3SJ-B1265P25
66 1,345 F3SJ-B1345P25
70 1,425 F3SJ-B1425P25
74 1,505 F3SJ-B1505P25
78 1,585 F3SJ-B1585P25
82 1,665 F3SJ-B1665P25
86 1,745 F3SJ-B1745P25
90 1,825 F3SJ-B1825P25
94 1,905 F3SJ-B1905P25
98 1,985 F3SJ-B1985P25
102 2,065 F3SJ-B2065P25
*1 Protective height (mm) = Total sensor length
470
F3SJ-B Safety sensors
Accessories (sold separately)
Sensor mounting bracket
Appearance Specifications Application Remarks Order code
Top/bottom bracket Top/bottom bracket for F3SJ-E/B 2 for an emitter,
2 for a receiver, total of 4 per set
F39-LJB1
Intermediate bracket In combination use with top/bottom bracket for F3SJ-E/B
Can be used as free-location bracket.
1 set with 2 pieces F39-LJB2*1 *2
Quick mount bracket Quick mount bracket for F3SJ-E/B
Supports M6 slide nut for aluminum frame.
Quick mount bracket for F3SJ-E/B
Supports M8 slide nut for aluminum frame.
1 set with 2 pieces F39-LJB3-M6*1
F39-LJB3-M8*2
Quick mount M6 brack- Bracket to mount an intermediate bracket to the aluminum frame
Hexagon socket head
F39-LJB3-M6K*1
et
Quick mount M8 brack- et
with a single touch.
cap screws
(M6 × 10) are included.
Hexagon socket head cap screws
(M8 × 14) are included.
F39-LJB3-M8K*2
Compatible mounting bracket
Mounting bracket used when replacing existing area sensors
(F3SJ-A or F3SN) with the F3SJ-E/B.
2 for an emitter,
2 for a receiver, total of 4 per set
F39-LJB4
Contact mount bracket Bracket to closely contact the back side of the sensor. 2 for an emitter,
2 for a receiver, total of 4 per set
F39-LJB5
*1 Combining F39-LJB2 and F39-LJB3-M6K makes F39-LJB3-M6.
*2 Combining F39-LJB2 and F39-LJB3-M8K makes F39-LJB3-M8.
Laser pointer
Appearance Output Order code
Laser pointer for F3SJ F39-PTJ
471
F3SJ-B Safety sensors
Specifications
Model F3SJ-B
P25
Sensor type Type 4 safety light curtain
Setting tool connection*1
Parameter settings: Not available
Safety category Safety purpose of category 4, 3, 2, 1, or B Detection capability Opaque objects 25 mm in diameter Beam gap (P) 20 mm
Number of beams (n) 8 to 102
Protective height (PH) 185 to 2,065 mm
Lens diameter Diameter 5 mm
Operating range*2
Response time (under stable light incident condition)
0.2 to 7 m
ON to OFF 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
OFF to ON 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
Startup waiting time 2 s max.
Power supply voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Consumption current (no load) Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max.,
66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max.
Receiver: Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max.,
66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max.
Light source (emitted wavelength) Infrared LED (870 nm)
Effective aperture angle (EAA) Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over
Safety outputs (OSSD) Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current
1 mA max., load inductance 2.2 H max.*3, Maximum capacity load 1 F*4
Auxiliary output 1 One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA
max.
Output operation mode Safety output: On when receiving light
Auxiliary output:
– Reverse output of safety output for a basic system
– ON when muting/override for a muting system
Input voltage ON voltage: Vs-3 V to Vs, OFF voltage: 0 V to 1/2 Vs or open*5
Mutual interference prevention function
Mutual interference prevention algorithm prevents interference in up to 3 sets.
Series connection Time division emission by series connection
Number of connections: up to 3 sets (between F3SJ-Bs only)Other models cannot be connected. Total number of beams: up to 192 beams
Maximum cable length for 2 sets: no longer than 7 m
Test function Self test (at power-ON and at power distribution) External test (emission stop function by test input)
Safety-related functions Interlock (basic system)
External device monitoring (basic system) Muting (muting system)
Override (muting system)
Connection type Connector method (M12, 8-pin)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: –10 to 55°C (non-freezing), Storage: –25 to 70°C Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH Operating ambient light intensity Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. Insulation resistance 20 M min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz, 1 min
Degree of protection IP65 (IEC 60529)
Vibration resistance Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Shock resistance Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Pollution degree Pollution degree 3 (IEC 60664-1)
Power cable Connection method: Prewired connector cable, cable length 0.3 m, connector type (M12, 8-pin), connector: IP67 rated (when mated) Number of wires: 8 wires
Cable diameter: Dia. 6 mm
Allowable bending radius: R5 mm
Extension cable 30 m max.
Material Case: Aluminum
Cap: ABS resin, PBT
Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC
Weight (packed state) Weight (g) = (protective height) × 2.7 + 500
Accessories Test rod, Instruction manual, User's manual (CD-ROM)*6
Applicable standards IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-sensitive protective equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active opto-electronic protective devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe, Cat.4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
*1 Do not use the support software and setting console for F3SJ-A. Operation cannot be guaranteed.
*2 Use of the spatter protection cover causes a 10% maximum sensing distance attenuation.
*3 The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*4 These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5 The Vs indicates a voltage value in your environment.
*6 Mounting brackets are sold separately.
472
F3SJ-B Safety sensors
Connections
Basic Wiring Diagram
Wiring when using manual reset mode, external device monitoring (F3SJ-B P25) (PNP output)
F39-JD_A-L F39-JD_A-D
(Gray) Communication line (+) (Pink)
Communication line (−)
S1 S2
KM1
KM2
K1 KM1 KM2
24 VDC Power
supply
0 V
S1 : External test switch (connect to 0 V if a switch is not required) S2 : Interlock/lockout reset switch
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
K1 : Load or PLC, etc. (for monitoring)
473

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSafety light curtain, Category 4 / PLe, 25mm resolution, standard function, 0.2m - OMRON - F3SJ-BEnglish250 Kbytespdf1-mostradoSafety light curtain, Category 4 / PLe, 25mm resolution, standard function, 0.2m - OMRON - F3SJ-B
pdf1-Safety light curtain, Category 4 / PLe, 25mm resolution, standard function, 0.2m - OMRON - F3SJ-B1985P25 English16 Mbytespdf1-mostradoSafety light curtain, Category 4 / PLe, 25mm resolution, standard function, 0.2m - OMRON - F3SJ-B

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or