7 5 W Tr i p l e O u t p u t w i t h P F C F u n c t i o n
7 5 W Tr i p l e O u t p u t w i t h P F C F u n c t i o n
7 5 W Tr i p l e O u t p u t w i t h P F C F u n c t i o n
T P - 7-5s e r i e s
T P - 7-5s e r i e s
T P - 7-5s e r i e s
Features :
Features :
Features :
Universal AC input / Full range
Universal AC input / Full range
Universal AC input / Full range
Built-in active PFCfunction, PF>0.95
Built-in active PFCfunction, PF>0.95
Built-in active PFCfunction, PF>0.95
Protections: Short circuit / Overload / Over voltage
Protections: Short circuit / Overload / Over voltage
Protections: Short circuit / Overload / Over voltage
Low profile: 33mmthickness
Low profile: 33mmthickness
Low profile: 33mmthickness
LED indicator for power on
LED indicator for power on
LED indicator for power on
Cooling by free air convection
Cooling by free air convection
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
Fixed switching frequency at PFC:67KHz PWM:134KHz
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
3 years warranty
3 years warrantySPECIFICATION
SPECIFICATION
SPECIFICATION
MODEL
MODEL
MODEL
TP-75ATP-75BTP-75C
TP-75ATP-75BTP-75C
TP-75ATP-75BTP-75C
OUTPUT NUMBER DC VOLTAGE
OUTPUT NUMBER DC VOLTAGE
OUTPUT NUMBER DC VOLTAGE
CH1
CH1
CH1
5V
5V
5V
CH2
CH2
CH2
12V
12V
12V
CH3
CH3
CH3
-5V
-5V
-5V
CH1
CH1
CH1
5V
5V
5V
CH2
CH2
CH2
12V
12V
12V
CH3
CH3
CH3
-12V
-12V
-12V
CH1
CH1
CH1
5V
5V
5V
CH2
CH2
CH2
15V
15V
15V
CH3
CH3
CH3
-15V
-15V
-15V
RATED CURRENT CURRENT RANGE
RATED CURRENT CURRENT RANGE
RATED CURRENT CURRENT RANGE
RATED POWER
RATED POWER
RATED POWER
7A 3A 0.6A7A 3A 0.4A6A 2.5A0.5A
7A 3A 0.6A7A 3A 0.4A6A 2.5A0.5A
7A 3A 0.6A7A 3A 0.4A6A 2.5A0.5A
1.5 ~ 10A0.2 ~ 4A0 ~ 0.6A1.5 ~ 10A0.2 ~ 4A0 ~ 0.6A1.5 ~ 10A0.2 ~ 3A0 ~ 0.6 TO
1.5 ~ 10A0.2 ~ 4A0 ~ 0.6A1.5 ~ 10A0.2 ~ 4A0 ~ 0.6A1.5 ~ 10A0.2 ~ 3A0 ~ 0.6 TO
1.5 ~ 10A0.2 ~ 4A0 ~ 0.6A1.5 ~ 10A0.2 ~ 4A0 ~ 0.6A1.5 ~ 10A0.2 ~ 3A0 ~ 0.6 TO
74W 75.8W75W
74W 75.8W75W
74W 75.8W75WOUTPUT
OUTPUT
OUTPUT
RIPPLE & NOISE (max.)Note.2100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p
RIPPLE & NOISE (max.)Note.2100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p
RIPPLE & NOISE (max.)Note.2100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p
VOLTAGE ADJ. RANGE of
VOLTAGE ADJ. RANGE of
VOLTAGE ADJ. RANGE of
CH1: 4.75 ~ 5.5 V
CH1: 4.75 ~ 5.5 V
CH1: 4.75 ~ 5.5 V
VOLTAGE TOLERANCE Note.3 3.0%
VOLTAGE TOLERANCE Note.3 3.0%
VOLTAGE TOLERANCE Note.3 3.0%
4.0%
4.0%
4.0%
8.0%
8.0%
8.0%
3.0%
3.0%
3.0%
4.0%
4.0%
4.0%
8.0%
8.0%
8.0%
3.0%
3.0%
3.0%
4.0%
4.0%
4.0%
8.0%
8.0%
8.0%
LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION
1.0%
1.0%
1.0%
3.0%
3.0%
3.0%
1.0%
1.0%
1.0%
4.0%
4.0%
4.0%
1.0%
1.0%
1.0%
8.0%
8.0%
8.0%
1.0%
1.0%
1.0%
3.0%
3.0%
3.0%
1.0%
1.0%
1.0%
4.0%
4.0%
4.0%
1.0%
1.0%
1.0%
8.0%
8.0%
8.0%
1.0%
1.0%
1.0%
3.0%
3.0%
3.0%
1.0%
1.0%
1.0%
4.0%
4.0%
4.0%
1.0%
1.0%
1.0%
8.0%
8.0%
8.0%
SETUP, RISE TIME HOLD TIME (Typ.)
SETUP, RISE TIME HOLD TIME (Typ.)
SETUP, RISE TIME HOLD TIME (Typ.)
Around 800ms, 60ms at full load
Around 800ms, 60ms at full load
Around 800ms, 60ms at full load
36ms at full load
36ms at full load
36ms at full load
VOLTAGE RANGENote.5 90 ~ 264VAC 127 ~ 370VDC
VOLTAGE RANGENote.5 90 ~ 264VAC 127 ~ 370VDC
VOLTAGE RANGENote.5 90 ~ 264VAC 127 ~ 370VDC
INPUT
INPUT
INPUTPROTECTION
PROTECTION
PROTECTION
ENVIRONMENT
ENVIRONMENT
ENVIRONMENT
SAFETY AND EMC
SAFETY AND EMC
SAFETY AND EMC
(Note 4)
(Note 4)
(Note 4)OTHER
OTHER
OTHER
FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) THE LEAKAGE CURRENT
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) THE LEAKAGE CURRENT
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) THE LEAKAGE OF CURRENTOVERLOAD
The OVERHEAD of
OVERLOADOVER VOLTAGE WORKING TEMP.
OVER VOLTAGE WORKING TEMP.
OVER VOLTAGE WORKING TEMP.
OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS
SAFETY STANDARDS
SAFETY STANDARDS
VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
EMC IMMUNITY
EMC IMMUNITY
EMC IMMUNITY
MTBF DIMENSION
MTBF DIMENSION
MTBF DIMENSION
PACKAGING
PACKAGING
PACKAGING
47 ~ 63Hz
47 ~ 63Hz
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
PF>0.95/230VAC PF>0.98/115VAC at full load
PF>0.95/230VAC PF>0.98/115VAC at full load
70%
70%
70%
1.5 A/115VAC 0.8 A/230VAC COLD START 20A/230VAC
1.5 A/115VAC 0.8 A/230VAC COLD START 20A/230VAC
1.5 A/115VAC 0.8 A/230VAC COLD START 20A/230VAC
<2mA / 240VAC
<2mA / 240VAC
<2mA / 240VAC
105 ~ 150% rated output power
105 ~ 150% rated output power
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75 V ON +5V
5.75 ~ 6.75 V ON +5V
5.75 ~ 6.75 V ON +5V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to "Reduction Curve")
-10 ~ +60 (Refer to "Reduction Curve")
-10 ~ +60 (Refer to "Reduction Curve")
20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing
-20 ~ +85, 10 ~ 95% RH
-20 ~ +85, 10 ~ 95% RH
-20 ~ +85, 10 ~ 95% RH
0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, y, Z axes
UL60950-1, TUV EN60950-1 approved
UL60950-1, TUV EN60950-1 approved
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVACI/P-FG:2KVACO/P-FG:0.5 KVAC 1min.
I/P-O/P:3KVACI/P-FG:2KVACO/P-FG:0.5 KVAC 1min.
I/P-O/P:3KVACI/P-FG:2KVACO/P-FG:0.5 KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
198.4 K hrs min. MIL-HDBK-217F (25)
198.4 K hrs min. MIL-HDBK-217F (25)
198.4 K hrs min. MIL-HDBK-217F (25)
179*99*33mm (L*W*H)
179*99*33mm (L*W*H)
179*99*33mm (L*W*H)
0.65 Kg; 20pcs/12.7 Kg/0.64 CUFT
0.65 Kg; 20pcs/12.7 Kg/0.64 CUFT
0.65 Kg; 20pcs/12.7 Kg/0.64 CUFTNOTE
NOTE
NOTE
1. All parameters NOT specially mentioned are measured at 230vac input, ratedload and 25 of ambient temperature.
1. All parameters NOT specially mentioned are measured at 230vac input, ratedload and 25 of ambient temperature.
1. All parameters NOT specially mentioned are measured at 230vac input, ratedload and 25 of ambient temperature.
2. Ripple and noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
2. Ripple and noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
2. Ripple and noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (available in http://www.meanwell.com)
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (available in http://www.meanwell.com)
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (available in http://www.meanwell.com)
5. The reduction may be necessary underlow input voltages. Please checkthe of the curve of reduction of power for more details.
5. The reduction may be necessary underlow input voltages. Please checkthe of the curve of reduction of power for more details.
5. The reduction may be necessary underlow input voltages. Please checkthe of the curve of reduction of power for more details.
Fil e Name:TP-75-SPEC2014-12-12
Fil e Name:TP-75-SPEC2014-12-12
Fil e Name:TP-75-SPEC2014-12-12