CS-66/200 111698 0002466122 EATON ELECTRIC Wall enclosure, +mounting plate, HxWxD 600x600x200mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CS-66/200 111698 0002466122 EATON ELECTRIC Wall enclosure, +mounting plate, HxWxD 600x600x200mm

CS-66/200

111698

0002466122

EATON-MOELLER

Wall enclosure, +mounting plate, HxWxD=600x600x200mm

CS-66/200

Eaton xEffect CS LV systems Switch- & Controlgear Enclosure. Wall enclosure with mounting plate, HxWxD=600x600x200mm

More details


Cabinet enclosures > Enclosure/switchgear cabinet (empty)

Enclosures

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $199.00
Unit price: $199.00

Quantity Price
1+$199.00
2+$191.14
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



General specifications

Product Name
Eaton xEffect CS enclosure single door
Catalog Number
111698
Model Code
CS-66/200
EAN
4015081112579
Product Length/Depth
200 mm
Product Height
600 mm
Product Width
600 mm
Product Weight
22.22 kg
Compliances
UL 508A; CSA-C22.2 No.14; IEC/EN 62208; CE marking
UL CSA09 (may be provided with metal sub-panel, no back mounted components are allowed between sub-panel and the back sheet metal enclosure)
RoHS conform
Certifications
IEC/EN 62208
UL CSA08 (request filed)
In accordance with Directive 2015/863/EU of the European Parliament and Council
UL (Category Control Number NITW)
UL (File No. E336299)

Delivery program

Type
Wall-mounting housing CSWall-mounting housing with mounting plate
Color
Light gray (RAL 7035)
Gray

Technical data - mechanical

Design type
Canted and seam welded, including two M6 threaded bolts for earth conductor connections inside the enclosure.
Surface finishing
Powder coating
Gloss
Structured powder spray polyester based paint finish
Semi-textured
Surface treatment
Structured powder spray polyester based paint finish
Mounting method
9 mm drilling dimensions for wall mounting (Back plate)
Wall fastening
Intermediate mounting
Mounting plate height
570 mm
Mounting plate material
Sheet steel, hot-galvanized
Mounting plate width
550 mm
Material
Steel plate
Steel
Material thickness (body)
1.5 mm
Material thickness (bottom plate)
2 mm
Material thickness (door)
1.5 mm
Material quality
Other
Degree of protection
IP66
12 (NEMA)
IK09 (impact resistance)
IP23 (with ventilating plates)
IK09
IEC: IP66, indoor; UL/CSA Types 1, 12, indoor only.
Number of F3A flanges
2
Number of connector holes
0
Number of covers/doors
1
Number of hinges
2
Number of locks
2
Load capacity (door)
25 kg
Load capacity (mounting plate)
500 kg payload, when brackets fitted in all four enclosure corners (vertically or horizontally) and the weights are symmetrically distributed within the enclosure.
250 kg
Permissible load of the door(s) according to IEC 62208 - max
250 N
Permissible load of the enclosure according to IEC 62208 - max
2750 N
Permissible load of the mounting plate according to IEC 62208 - max
2500 N
Weight of mounted components - max
275 kg
Cover/door angle
120° door opening angle
Cover/door profile
2 door profiles
Cover/door type
Standard closure 3 mm double-ward key (door interlock)
Door hinges on the right, can be converted by user
Closed
Flange plate dimensions
172 mm x 432 mm
Installation site
Indoor installation
Installation type
Floor standing wall model
Thickness of mounting plate
2 mm
Climatic proofing
Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30

Temperature-rise verification as per IEC 60890

Heat diss. ambient 35°C delta T: 20°C wall mount middle encl. top (IEC 60890)
48 W
Heat diss. ambient 35°C delta T: 35°C wall mount middle encl. top (IEC 60890)
99 W
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890)
54 W
Heat diss. ambient 35°C delta T:20°C wall mount starting encl. top (IEC 60890)
51 W
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890)
110 W
Heat diss. ambient 35°C delta T:35°C wall mount starting encl. top (IEC 60890)
104 W
Heat diss. wall mount individual encl. top
54 W
Heat diss. wall mount middle encl. top
48 W
Heat diss. wall mount starting encl. top
51 W
Thermal dissipation (Delta T = 20 K) according to IEC/TR 60890
54 W

Design verification as per IEC/EN 61439 - technical data

Ambient operating temperature details
-25 °C - 40 °C

Design verification as per IEC/EN 61439

10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2.6 Mechanical impact
IK09
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
IP66
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
< 0.1 Ω; meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Ui = 1000 V AC
10.9.3 Impulse withstand voltage
Does not apply to basic enclosures as defined in EN 62208.
10.9.4 Testing of enclosures made of insulating material
Does not apply to metal enclosures.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.

Additional information

Features
Pole fastening
Wall build in
Fitted with:
Mounting plate
Including M6 threaded welded studs for earth conductor connections in the door:
Cover
Door
Functions
Floor standing enclosure
RAL-number
7035
Special features
Bottom plate enclosed, foamed gasket, can be unscrewed for F3A-… flanges or for assembly by userFoamed polyurethane sealing throughout.Impact resistance category IK09 to EN 62262.Sheet steel mounting plateBottom plate with foamed gasket.Single door, door stop on the right, door opening angle 120°Door hinge pins with quick change technology.Standardized locking system with sash fastener.Powder coating RAL 7035 inside and outsideLock, 3 mm double ward keyIncluding M6 threaded welded studs for earth conductor connections in the doorSide plates without aperturesTop plate without apertures
Suitable for
Metrical mounting
Used with
Industrial control panels

Datasheet - PDF

Title: Size: Type:
CS-66/200 0002466122 111698 EN_138763.pdf 3 Mbytes   CS-66/200 0002466122 111698 EN_138763.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.