DILM32-XTED11-1(RAC130) 105211 EATON MOELLER Timer module, 100-130VAC, 0.05-1s, off-delayed View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM32-XTED11-1(RAC130) 105211 EATON MOELLER Timer module, 100-130VAC, 0.05-1s, off-delayed

DILM32-XTED11-1(RAC130)

105211

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Timer module, 100-130VAC, 0.05-1s, off-delayed

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

DIL Contactor Relays - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$37.98
4+$35.69
7+$35.01
10+$34.63
13+$34.39
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Accessories
Accessories
  Timer modules
Description
  Off-delayed, auxiliary voltage-free
Cannot be combined with top mounting auxiliary contacts
Incl. suppressor circuits
Voltage range
ULNV100 - 130 V AC
Time range
  0.05 - 1 s
For use with
  DILM7 - DILM32
DILMP20
DILMP32-DILMP45
DILA
Contact sequence
  
General
Ambient temperature
   
Open
 °C-25 - +60
Contacts
Rated impulse withstand voltage
UimpV AC4000
Rated insulation voltage
UiV AC250
Rated operational voltage
UeV250
Short-circuit rating without welding
   
max. fuse
 A gG/gL6
Magnet systems
Power consumption
   
AC operated
SealingW1.8
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA0
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW1.8
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C60
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Relays (EG000019) / Timer block (EC002060)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Timer block attachment ([email protected] [ACN996008])
Switching function
  Time-delay dropped out
Setting time
 s0.05 - 1
Number of contacts as normally open contact
  1
Number of contacts as normally closed contact
  1
Number of contacts as change-over contact
  0
Operating principle
  Electronic
Approvals
Product Standards  IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.  E29184
UL Category Control No.  NKCR
CSA File No.  012528
CSA Class No.  3211-03
North America Certification  UL listed, CSA certified
Dimensions
IL04910004Z (AWA2527-2320) Electronical timer
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields