T5-4-8213/X 096013 EATON MOELLER P & T switches View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

T5-4-8213/X 096013 EATON MOELLER P & T switches

T5-4-8213/X

096013

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

P & T switches

More details


T Cam switches and P Switch-disconnectors - EATON - MOELLER

Switch-disconnectors - changeover switches - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$228.39
2+$223.08
3+$220.45
4+$220.13
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Control switches
Part group reference
  T5
Basic function
  Changeoverswitches
Contacts
  8
Design
  rear mounting
Basic switch
Contact sequence
  
General
Standards
  IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +50
Enclosed
 °C-25 - +40
Overvoltage category/pollution degree
  III/3
Rated impulse withstand voltage
UimpV AC6000
Mechanical shock resistance
 g15
Mounting position
  As required
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Contacts
Electrical characteristics
   
Rated operational voltage
UeV AC690
Rated uninterrupted current
IuA100
Note on rated uninterrupted current !u
  Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
   
AB 25 % DF
 x Ie2
AB 40 % DF
 x Ie1.6
AB 60 % DF
 x Ie1.3
Short-circuit rating
   
Fuse
 A gG/gL100
Rated short-time withstand current (1 s current)
IcwArms1700
Note on rated short-time withstand current lcw
  Current for a time of 1 second
Rated conditional short-circuit current
IqkA2
Switching capacity
cos ϕ rated making capacity as per IEC 60947-3
 A950
Rated breaking capacity cos ϕ to IEC 60947-3
 A 
230 V
 A760
400/415 V
 A740
500 V
 A590
690 V
 A420
Safe isolation to EN 61140
   
between the contacts
 V AC440
Current heat loss per contact at Ie
 W7.5
Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
 CO7.5
Lifespan, mechanical
Operationsx 106> 0.5
Maximum operating frequency
Operations/h 1200
AC
   
AC-3
   
Rating, motor load switch
PkW 
220 V 230 V
PkW22
230 V Star-delta
PkW30
400 V 415 V
PkW30
400 V Star-delta
PkW45
500 V
PkW30
500 V Star-delta
PkW45
690 V
PkW15
690 V Star-delta
PkW22
Rated operational current motor load switch
   
230 V
IeA71
230 V star-delta
IeA100
400V 415 V
IeA55
400 V star-delta
IeA95.3
500 V
IeA44
500 V star-delta
IeA76.2
690 V
IeA17
690 V star-delta
IeA29.4
AC-21A
   
Rated operational current switch
   
440 V
IeA100
AC-23A
   
Motor rating AC-23A, 50 - 60 Hz
PkW 
230 V
PkW30
400 V 415 V
PkW55
500 V
PkW37
690 V
PkW30
Rated operational current motor load switch
   
230 V
IeA100
400 V 415 V
IeA100
500 V
IeA55
690 V
IeA32
DC
   
DC-1, Load-break switches L/R = 1 ms
   
Rated operational current
IeA80
Voltage per contact pair in series
 V60
Control circuit reliability at 24 V DC, 10 mA
Fault probabilityHF< 10 -5, < 1 fault in 100000 operations
Terminal capacities
Solid or stranded
 mm21 x (2,5 - 35)
2 x (2,5 - 16)
Flexible with ferrules to DIN 46228
 mm21 x (1 - 25)
2 x (1.5 - 10)
Terminal screw
  M6
Max. tightening torque
 Nm4
Technical safety parameters:
Notes
  B10d values as per EN ISO 13849-1, table C1
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Off-load switch (EC001105)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Changeover switch ([email protected] [AKF062010])
Model
  Reverser
Number of poles
  4
With 0 (off) position
  Yes
With retraction in 0-position
  No
Rated permanent current Iu
 A100
Rated operation current Ie at AC-3, 400 V
 A55
Rated operation power at AC-3, 400 V
 kW30
Degree of protection (IP), front side
  -
Number of auxiliary contacts as normally closed contact
  0
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as change-over contact
  0
Suitable for ground mounting
  No
Suitable for front mounting 4-hole
  Yes
Suitable for distribution board installation
  No
Suitable for intermediate mounting
  No
Complete device in housing
  No
Type of control element
  -
Type of electrical connection of main circuit
  Screw connection

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or