INX40B4-10F 150094 EATON MOELLER Switch-disconnector, 4p, 1000 A, fixed View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

INX40B4-10F 150094 EATON MOELLER Switch-disconnector, 4p, 1000 A, fixed

INX40B4-10F

150094

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Switch-disconnector, 4p, 1000 A, fixed

More details


Circuit Breakers Electrical Power

Circuit-breakers IZM - EATON - MOELLER

IN switch-disconnectors - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Air circuit-breakers/switch-disconnectors
Product range
  Open switch-disconnectors
Current Range
  Up to 4000 A
Installation type
  Fixed
Construction size
  INX40
Release system
  without releases
Standard/Approval
  IEC
Number of poles
  4 pole
Degree of Protection
  IP20, IP55 with protective cover, IP41 door sealing frame
 
  optionally fittable by user with comprehensive accessories
Rated current = rated uninterrupted current
In = IuA1000
Making capacity Icm to 440 V 50/60 Hz
IcmkA145
t = 1 s
IcwkA66
t = 3 s
IcwkA53
Technical data
General
Standards
  IEC/EN 60947
Ambient temperature
   
Storage
ϑ°C-40 - +70
Ambient temperature
 °C-25 - +70
Mounting position
  
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA1000
Equipment heat dissipation, current-dependent
PvidW55
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ([email protected] [AKF060010])
Version as main switch
  Yes
Version as maintenance-/service switch
  No
Version as safety switch
  No
Version as emergency stop installation
  No
Version as reversing switch
  No
Max. rated operation voltage Ue AC
 V690
Rated operating voltage
 V690 - 690
Rated permanent current Iu
 A1000
Rated permanent current at AC-21, 400 V
 A0
Rated operation power at AC-3, 400 V
 kW0
Rated short-time withstand current lcw
 kA66
Rated operation power at AC-23, 400 V
 kW0
Switching power at 400 V
 kW0
Conditioned rated short-circuit current Iq
 kA144
Number of poles
  4
Number of auxiliary contacts as normally closed contact
  0
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as change-over contact
  2
Motor drive optional
  Yes
Motor drive integrated
  No
Voltage release optional
  Yes
Device construction
  Built-in device fixed built-in technique
Suitable for ground mounting
  Yes
Suitable for front mounting 4-hole
  No
Suitable for front mounting center
  No
Suitable for distribution board installation
  Yes
Suitable for intermediate mounting
  No
Colour control element
  Green
Type of control element
  Push button
Interlockable
  Yes
Type of electrical connection of main circuit
  Rail connection
Degree of protection (IP), front side
  IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or