IN32B3-12W 123643 EATON MOELLER Break switch, 3P, 1250A, removable without chassis

IN32B3-12W

123643

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Break switch, 3P, 1250A, removable without chassis

More details


Circuit-breakers IZM - EATON - MOELLER

IN switch-disconnectors - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

Up to 35% discount for registered clients. * This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.
EXPRESS quotation request, you will get an answer in a few minutes

IN32B3-12W 123643 EATON MOELLER Break switch, 3P, 1250A, removable without chassis

Enter your contact details and submit your request, you will be notified by email with a quotation. You simply finish your order and you will receive the products.






* Required fields

or 

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Air circuit-breakers/switch-disconnectors
Product range
  Open switch-disconnectors
Current Range
  over 4000 A
Protective function
  Switch disconnector
Installation type
  Withdrawable
Construction size
  IN32
Release system
  Electronic release
Standard/Approval
  IEC
Number of poles
  3 pole
Degree of Protection
  IP20, IP55 with protective cover
Rated current = rated uninterrupted current
In = IuA1250
Making capacity Icm to 440 V 50/60 Hz
IcmkA55
t = 1 s
IcwkA65
Notes 

Including rear connection main terminals and secondary terminal blocks according to ordered breaker options.

Note concerning the product 

Cassette needs to be ordered separately.

Technical data
General
Standards
  IEC/EN 60947
Ambient temperature
   
Storage
ϑ°C-40 - +70
Operating (open)
 °C-25 - +70
Mounting position
  >>
Utilization category
  B
Degree of Protection
  IP20, IP55 with protective cover
Direction of incoming supply
  as required
Main conducting paths
Rated current = rated uninterrupted current
In = IuA1250
Rated uninterrupted current at 50 °C
IuA1250
Rated uninterrupted current at 60 °C
IuA1250
Rated uninterrupted current at 70 °C
IuA1250
Rated impulse withstand voltage
UimpV AC8000
Rated operational voltage
UeV AC690
Use in IT electrical power networks up to U = 440 V
IITkA13
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV1000
Switching capacity
Rated short-circuit making capacity
Icm  
up to 440 V 50/60 Hz
IcmkA55
up to 690 V 50/60 Hz
IcmkA143
Rated short-time withstand current 50/60 Hz
   
t = 1 s
IcwkA65
Operating times
   
Closing delay via spring release
 ms35
Break times
 ms40
Total opening delay via shunt release
 ms30
Total opening delay via undervoltage release
 ms35/70
Maximum operating frequency
 Ops./h 
Maximum operating frequency
Operations/h 60
Heat dissipation at rated current In
   
Fixed mounting
 W90
Withdrawable units (switch with cassette)
 W200
Weight
Fixed mounting
   
3-pole
 kg58
4-pole
 kg72
Withdrawable
   
3-pole
 kg70
4-pole
 kg88
Cassette
   
3 pole
 kg34
4 pole
 kg38
Terminal capacities
Copper bar
   
Fixed mounting
   
Black
 mm2 x 5 x 80
Withdrawable units
   
Black
 mm2 x 5 x 80
 
  

Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation.

Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
Dimensions
>
>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or