SPPT2PA-1000-2+1PE-AX 132665 EATON ELECTRIC Plug-in surge arrester with auxiliary contact, 1000 V DC, 2p+PE,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SPPT2PA-1000-2+1PE-AX 132665 EATON ELECTRIC Plug-in surge arrester with auxiliary contact, 1000 V DC, 2p+PE,..

SPPT2PA-1000-2+1PE-AX

132665

EATON-MOELLER

Plug-in surge arrester with auxiliary contact, 1000 V DC, 2+Npole, non-earthed

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery program
Product range
DC overvoltage protection
Products
Surge arresters
Application field
Residential buildings
Utility buildings
Open areas
Description
pluggable
With auxiliary contact
Connection
For ungrounded systems
Maximum uninterrupted voltage
Uc V 1000
Technical data ETIM 7.0
Earthing, lightning and surge protection (EG000021) / Surge protection device for power supply systems (EC000941)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Surge protection device for power supply systems ([email protected] [ACN278011])
System configuration DC
No
System configuration IT
Yes
System configuration TN
No
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
No
System configuration TT
No
System configuration other
No
Number of conductors (without earthing)
Nominal discharge surge current (8/20)
kA 15
Nominal voltage AC
V 0
Nominal voltage DC
V 1000
Short-circuit breaking capacity (Isccr)
kA
Max. continuous voltage AC
V 0
Max. discharge surge current (8/20)
kA
Max. continuous voltage DC
V 1000
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
3 modular spacing
Max. PV-voltage
V 1050
Voltage protection level
kV 5
Max. conductor cross section solid (solid, stranded)
mm² 25
Max. conductor cross section flexible (fine-strand)
mm² 35
Voltage protection level L-N
kV 0
Voltage protection level N-PE
kV 0
With remote signalling contact
No
Integrated backup fuse
No
Signalling at the device
None
Category type 2
Yes
Degree of protection (IP)
IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.