CI-K5-T5-4 207442 0001456994 EATON ELECTRIC Insulated enclosure, HxWxD 280x200x125mm for T5-4 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CI-K5-T5-4 207442 0001456994 EATON ELECTRIC Insulated enclosure, HxWxD 280x200x125mm for T5-4

CI-K5-T5-4

207442

0001456994

EATON-MOELLER

Insulated enclosure, HxWxD=280x200x125mm for T5-4

CI-K5-T5-4

More details


Low-voltage industrial components > Empty enclosure for switchgear

Disconnectors and Cam Switches

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $103.92
Unit price: $103.92

Quantity Price
1+$103.92
2+$88.82
3+$82.27
4+$79.67
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



EL-Nummer (Norway)
1456994
Insulated enclosure, HxWxD=280x200x125mm for T5-4
Small enclosure, degree of protection IP65, glass-fibre reinforced polycarbonate, enclosure base RAL 9005, black/operator only RAL 7035, light gray, metric cable entry knockouts top, bottom and in the back plate, hard metric cable entry knockouts, control cable entry, indicator light L-. can be mounted in base knock-out M20/M25, for T5-../Z switch, 2-4 contact units

Delivery program

Basic function
insulated enclosure
with metric knock-outs
For use with
T5-…/Z
For use with
3 - 4 contact units
Information about equipment supplied
with an additional PE clamp
Degree of Protection
IP65
Notes
1 contact unit = 2 contacts

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
41 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+40 °C
Max. radiated heat dissipation with separate mounting, ambient air temperature +20 °C
41 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Empty enclosure for switchgear (EC000712)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Empty housing for switch devices ([email protected] [AKN343014])
Material housing
Plastic
Width
200 mm
Height
280 mm
Depth
125 mm
With transparent cover
No
Suitable for emergency stop
No
Model
Surface mounting
Degree of protection (IP)
IP65
Degree of protection (NEMA)
Other

Approvals

Product Standards
UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
UL File No.
E54120
UL Category Control No.
MITW2
CSA File No.
12528
CSA Class No.
3211-07
North America Certification
UL listed, CSA certified
Degree of Protection
IEC: IP65; UL/CSA Type 1, 12

Dimensions

1150DIM-204

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.