Product name
Eaton xComfort IKA standard series
Product Length/Depth
145 millimetre
Product height
586 millimetre
Product width
310 millimetre
Product weight
3.77 kilogram
Certifications
EN 62208
IEC/EN 60670-24
Product Tradename
xComfort IKA
Product Type
Standard series
Type
Basic deviceIKA standard distribution boardInstallation distribution board
Application
Indoor (installation site)
Color
Gray
Light gray (RAL 7035)
Technical Data - Electrical
Voltage rating at AC
415 V AC
Frequency rating of contacts
50 Hz
Technical Data - Mechanical
Enclosure material
Plastic
Width in number of modular spacings
12
Mounting method
DIN-rail
Surface mounted (plaster)
Surface mounting
Degree of protection
IP65
IK08 (impact resistance)
Number of module space units per row
12
Terminal type
Without terminals
Cover/door color
Transparent
Cover/door model
With notch
Cover/door type
Door
Single
Module rack type
Rail frame
Protective shrouding material
Plastic
Temperature-rise verification as per IEC 60890
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890)
37 W
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890)
75 W
Design verification as per IEC/EN 61439 - technical data
Ambient operating temperature details
-25 °C - 40 °C
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
650 °C; meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2.6 Mechanical impact
IK08
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
IP65
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
Protection class 2, therefore not applicable.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Ui = 1000 V AC
10.9.3 Impulse withstand voltage
3.3 kV
10.9.4 Testing of enclosures made of insulating material
Meets the product standard's requirements.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.
Fitted with:
Sealing caps
Device support rails
Locking screws can be sealed
Current circuit designation
Basic device
Functions
Extension possible
Basic device
Protection class
II (totally insulated)
Special features
IP65Protection Class IIPlastic enclosure gray (RAL 7035)
Used with
Installation distribution board
Basic device
IKA standard distribution board