Switched-mode power supply unit, 100-240VAC/24VDC, 1.25A, 1-phase, controlled

EASY400-POW

Eaton Moeller® series EASY Switched-mode power supply unit, 100-240VAC/24VDC, 1.25A, 1-phase, controlled EASY400-POW

More details


PLC's > PLC system power supply

EASY programmable relays and MFD displays

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $154.78
Unit price: $154.78

Quantity Price
1+$154.78
2+$134.30
3+$124.47
4+$118.91
5+$118.66
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series EASY Accessory Switched-mode power supply unit
Catalog Number
212319
Model Code
EASY400-POW
EAN
4015082123192
Product Length/Depth
58 mm
Product Height
90 mm
Product Width
72 mm
Product Weight
0.185 kg
Certifications
IEC 60068-2-6
IEC 60068-2-27
IEC/EN 61000-4
EN 55011
EN 55022

Features & Functions

Features
Proof against sustained short circuit, hickup mode, approx. 2 Hz (Output current 24 V DC)
Overload proof (by current limitation)
Number of phases
1

General

Degree of Protection
IP20 (according to IEC/EN 60529, EN 50178, VBG 4)
Lamp load
10 W (at 24 V DC, cold)
LED indicator
Status Indication of 24 V DC output voltage: Continuous green light LED
Mounting Method
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Power consumption
35 W typ.
Power loss
Normally 5 W
Product category
Accessories
Rated frequency - min
47 Hz
Rated frequency - max
63 Hz
Rated operational voltage
100/120/230/240 (-15 %/+10 %)
Used with
easyE4
Voltage type
AC

Ambient conditions, mechanical

Constant acceleration
2 g, 57 - 150 Hz, according to IEC/EN 60068-2-6, Vibrations
Constant amplitude
0,15 mm, 10 - 57 Hz, according to IEC/EN 60068-2-6, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
1 m
Mounting position
Horizontal
Vertical
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Altitude
Max. 2000 m
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - max
70 °C
Ambient storage temperature - min
-40 °C
Environmental conditions
Condensation: prevent with appropriate measures
Clearance in air and creepage distances according to EN 50178
Relative humidity
5 - 95 % (non-condensing)

Electro magnetic compatibility

Air discharge
8 kV, according to IEC/EN 61000-4-2, Level 3, ESD
Burst impulse
2 kV, according to IEC/EN 61000-4-4, Level 3
Contact discharge
6 kV, according to IEC/EN 61000-4-2, Level 3, ESD
Electromagnetic fields
10 V/m (according to IEC EN 61000-4-3)
Immunity to line-conducted interference
10 V (according to IEC/EN 61000-4-6)
Radio interference class
Class B (EN 55011)
Class B (EN 55022)
Surge rating
0.5kV, outgoer cables symmetrical, EASY…DC, IEC/EN 61000-4-5, level 2, 24 V EMC
2 kV, Supply cables, symmetrical, power pulses (Surge), EMC
6 kV, Surge voltage (EN 50178), 24 V, EMV

Terminal capacities

Terminal capacity (flexible with ferrule)
0.2/2.5 mm²
Terminal capacity (flexible with ferrule AWG)
22 - 12
Terminal capacity (solid)
0.2/4 mm²
Terminal capacity (solid AWG)
22 - 12
Screwdriver size
3.5 x 0.8 mm, Terminal screw
Tightening torque
0.6 Nm, Screw terminals

Safety

Current limitation
1.5 A, effectiveness of current limitation, 24 V DC, output current
Insulation resistance
According to EN 50178
Potential isolation
SELV (VDE 0100 Part 410; IEC 60364-4-41, HD 384.4.41 S2) EN 60950, EN 50178 (primary/secondary)
Protection class
2 (IEC/EN 60536)

Input characteristics

Input current at AC - max
0.6 A
Input voltage at AC 50 Hz - min
85 V
Input voltage at AC 50 Hz - max
264 V
Input voltage at DC - min
0 V
Input voltage at DC - max
0 V
Inrush current
18 A (at 25 °C, 230 V)
Mains failure bridging
> 20 ms (at 115 V, according to IEC/EN 61000-4-11)
> 40 ms (at 230 V, according to IEC/EN 61000-4-11)
Supply voltage
24 V DC, Output voltage

Output characteristics

Efficiency
83 %
Output
Parallel switching
Output current at AC, 50 Hz - max
1.25 A
Output voltage
± 2 % (Effect with 25 - 100 % load change)
± 1 % (Effect of input voltage)
Output voltage at AC 50 Hz - max
18 V
Output voltage at DC - min
0 V
Output voltage at DC - max
24 V
Short-circuit protection rating
2/1 A slow, Fuse 115/230 V, Input voltage
Voltage tolerance
± 3 %, Rated output voltage

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
5 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.