Product successfully added to your shopping cart
LZMN3-4-A500/320-I
111976
EATON-MOELLER
1
Power Distribution Components IEC Moulded case circuit breaker
LZM circuit breaker, 4P, 500A, 320A
Circuit Breakers LZM
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | Circuit-breaker | ||
Protective function | System and cable protection | ||
Standard/Approval | IEC | ||
Installation type | Fixed | ||
Release system | Thermomagnetic release | ||
Construction size | LZM3 | ||
Description | Set value in neutral conductor is synchronous with set value Ir of main pole. | ||
Number of poles | 4 pole | ||
Standard equipment | Screw connection | ||
Switching capacity | |||
400/415 V 50 Hz | Icu | kA | 50 |
Rated current = rated uninterrupted current | |||
Rated current = rated uninterrupted current | In= Iu | A | 500 |
Neutral conductor | % of phase conductor | CSA | 60 |
Neutral conductor protection | Reduced neutral conductor protection | ||
Setting range | |||
Overload trip | |||
Ir | A | 400 - 500 | |
Main pole | Ir | A | 250 - 320 |
Short-circuit releases | |||
Non-delayed | Ii= Inx … | 6 - 10 |
General | |||||||||||||||
Standards | IEC/EN 60947, VDE 0660 | ||||||||||||||
Protection against direct contact | Finger and back-of-hand proof to VDE 0106 part 100 | ||||||||||||||
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||||||||||||||
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 | g | 20 (half-sinusoidal shock 20 ms) | |||||||||||||
Safe isolation to EN 61140 | |||||||||||||||
Between auxiliary contacts and main contacts | V AC | 500 | |||||||||||||
between the auxiliary contacts | V AC | 300 | |||||||||||||
Weight | kg | 8.4 | |||||||||||||
Mounting position |
| ||||||||||||||
Direction of incoming supply | as required | ||||||||||||||
Degree of protection | |||||||||||||||
Device | In the area of the HMI devices: IP20 (basic protection type) | ||||||||||||||
Enclosures | with insulating surround: IP40with door coupling rotary handle: IP66 | ||||||||||||||
Terminations | Tunnel terminal: IP10 Phase isolator and band terminal: IP00 | ||||||||||||||
Circuit-breakers | |||||||||||||||
Rated current = rated uninterrupted current | In= Iu | A | 500 | ||||||||||||
Rated surge voltage invariability | Uimp | ||||||||||||||
Main contacts | V | 8000 | |||||||||||||
Auxiliary contacts | V | 6000 | |||||||||||||
Rated operational voltage | Ue | V AC | 690 | ||||||||||||
Overvoltage category/pollution degree | III/3 | ||||||||||||||
Rated insulation voltage | Ui | V | 1000 | ||||||||||||
Use in unearthed supply systems | V | 690 | |||||||||||||
Switching capacity | |||||||||||||||
Rated short-circuit making capacity | Icm | ||||||||||||||
240 V 50/60 Hz | Icm | kA | 187 | ||||||||||||
400/415 V 50/60 Hz | Icm | kA | 105 | ||||||||||||
440 V 50/60 Hz | Icm | kA | 74 | ||||||||||||
525 V 50/60 Hz | Icm | kA | 53 | ||||||||||||
690 V 50/60 H | Ic | kA | 40 | ||||||||||||
Rated short-circuit breaking capacity Icn | Icn | ||||||||||||||
Icu to IEC/EN 60947 test cycle O-t-CO | Icu | kA | |||||||||||||
240 V 50/60 Hz | Icu | kA | 85 | ||||||||||||
400/415 V 50 Hz | Icu | kA | 50 | ||||||||||||
440 V 50/60 Hz | Icu | kA | 35 | ||||||||||||
525 V 50/60 Hz | Icu | kA | 25 | ||||||||||||
690 V 50/60 Hz | Icu | kA | 20 | ||||||||||||
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO | Ics | kA | |||||||||||||
230 V 50/60 Hz | Ics | kA | 85 | ||||||||||||
400/415 V 50/60 Hz | Ics | kA | 50 | ||||||||||||
440 V 50/60 Hz | Ics | kA | 35 | ||||||||||||
525 V 50/60 Hz | Ics | kA | 13 | ||||||||||||
690 V 50/60 Hz | Ics | kA | 5 | ||||||||||||
Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker. | |||||||||||||||
Rated short-time withstand current | |||||||||||||||
t = 0.3 s | Icw | kA | 3.3 | ||||||||||||
t = 1 s | Icw | kA | 3.3 | ||||||||||||
Utilization category to IEC/EN 60947-2 | A | ||||||||||||||
Rated making and breaking capacity | |||||||||||||||
Rated operational current | Ie | A | |||||||||||||
AC-1 | |||||||||||||||
380 V 400 V | Ie | A | 630 | ||||||||||||
415 V | Ie | A | 500 | ||||||||||||
690 V | Ie | A | 630 | ||||||||||||
AC--3 | |||||||||||||||
380 V 400 V | Ie | A | 450 | ||||||||||||
415 V | Ie | A | 450 | ||||||||||||
660 V 690 V | Ie | A | 450 | ||||||||||||
DC-1 | |||||||||||||||
500 V DC | Ie | CSA | 500 | ||||||||||||
750 V DC | Ie | CSA | 500 | ||||||||||||
DC - 3 | |||||||||||||||
500 V DC | Ie | CSA | 500 | ||||||||||||
750 V DC | Ie | CSA | 500 | ||||||||||||
Lifespan, mechanical | Operations | 15000 | |||||||||||||
Lifespan, electrical | |||||||||||||||
AC-1 | |||||||||||||||
400 V 50/60 Hz | Operations | 5000 | |||||||||||||
415 V 50/60 Hz | Operations | 5000 | |||||||||||||
690 V 50/60 Hz | Operations | 3000 | |||||||||||||
AC-2, AC-3 | |||||||||||||||
400 V 50/60 Hz | Operations | 2000 | |||||||||||||
415 V 50/60 Hz | Operations | 2000 | |||||||||||||
690 V 50/60 Hz | Operations | 2000 | |||||||||||||
DC-1 | |||||||||||||||
500 V DC | Operations | 5000 | |||||||||||||
750 V DC | Operations | 5000 | |||||||||||||
DC - 3 | |||||||||||||||
500 V DC | Operations | 2000 | |||||||||||||
750 V DC | Operations | 2000 | |||||||||||||
Max. operating frequency | Ops/h | 60 | |||||||||||||
Total downtime in a short-circuit | ms | < 10 | |||||||||||||
Terminal capacity | |||||||||||||||
Standard equipment | Screw connection | ||||||||||||||
Round copper conductor | |||||||||||||||
Tunnel terminal | |||||||||||||||
Solid | mm2 | 1 x (16 - 185) | |||||||||||||
Copper busbar (width x thickness) | mm | ||||||||||||||
Bolt terminal and rear-side connection | |||||||||||||||
Screw connection | M10 |
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 500 |
Equipment heat dissipation, current-dependent | Pvid | W | 130.5 |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010]) | |||
Rated permanent current Iu | A | 500 | |
Rated voltage | V | 690 - 690 | |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | kA | 50 | |
Overload release current setting | A | 400 - 500 | |
Adjustment range short-term delayed short-circuit release | A | 0 - 0 | |
Adjustment range undelayed short-circuit release | A | 3000 - 5000 | |
Integrated earth fault protection | No | ||
Type of electrical connection of main circuit | Screw connection | ||
Device construction | Built-in device fixed built-in technique | ||
Suitable for DIN rail (top hat rail) mounting | No | ||
DIN rail (top hat rail) mounting optional | No | ||
Number of auxiliary contacts as normally closed contact | 0 | ||
Number of auxiliary contacts as normally open contact | 0 | ||
Number of auxiliary contacts as change-over contact | 0 | ||
Switched-off indicator available | No | ||
With under voltage release | No | ||
Number of poles | 4 | ||
Position of connection for main current circuit | Front side | ||
Type of control element | Rocker lever | ||
Complete device with protection unit | Yes | ||
Motor drive integrated | No | ||
Motor drive optional | Yes | ||
Degree of protection (IP) | IP20 |
Title: | Size: | Type: |
---|---|---|
PDF EATON PRODUCT CATALOGUE LZM.pdf | 5 Mbytes | |
PDF CATALOGUE EATON EN.pdf | 51 Mbytes | |
EATON-111976-LZMN3-4-A500/320-I | 551 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.