DPC71DM48 CARLO GAVAZZI SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltage.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DPC71DM48 CARLO GAVAZZI SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltage..

DPC71DM48

DPC71DM48

CARLO GAVAZZI

Available

Ship on today

SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltage, phase sequence/loss, asymmetry, tolerance MOUTING DIN-rail INPUT RANGE 380÷480 VAC OTHERS VLN monitoring

More details


Energy Meters Control Analizers

Controls

Monitoring Relays and Measurement Current Transformers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$210.55
2+$205.46
3+$202.93
4+$201.75
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Monitoring Relays
True RMS 3-Phase, 3-Phase+N, Multifunction
Types DPC71, PPC71
DPC71 PPC71
• TRMS 3-phase over and under voltage,
phase sequence, phase loss, asymmetry and tolerance monitoring relay
• Detect when all 3 phases are present and have the correct sequence
• Detect if all the 3-phase-phase or phase-neutral voltages are within the set limits
• Detect if asymmetry and tolerance are within the set value
• Separately adjustable setpoints
• Separately adjustable delay functions (0.1 to 30 s)
• Output: 2 x 5 A relay SPDT NE
• For mounting on DIN-rail in accordance with
DIN/EN 50 022 (DPC71) or plug-in module (PPC71)
• 35.5 mm Euronorm housing (DPC71) or 35.5 mm plug- in module (PPC71)
• LED indication for relays, alarm and power supply ON
Product Description Ordering key
DPC 71 D M48
3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, tolerance, over and under voltage (sep- arately adjustable set points)
Type Selection
with built-in time delay func- tion.
Supply ranges from 208 to
480 VAC covered by two multivoltage relays.
Housing Function Type
Item number
Output
Power Supply
Supply: Supply: Supply: Mounting Output Frequency 208 to 240 VAC 380 to 415 VAC 380 to 480 VAC
DIN-rail 2 x SPDT 50 - 60 Hz DPC 71 D M23 DPC 71 D M48
Plug-in 2 x SPDT 50 - 60 Hz PPC 71 D M23 PPC 71 D M48
Input Specifications
Input
L1, L2, L3, N DPC71: Terminals L1, L2, L3, N PPC71: Terminals 5, 6, 7, 11
Measure their own supply
Note: Connect the neutral only if it is intrinsically at the star centre
Measuring ranges
M23 177 to 275 ∆VAC M48 DPC71 323 to 550 ∆VAC PPC71 323 to 475 ∆VAC
Ranges
Upper level +2 to +22%
of the nominal voltage
Lower level -22 to -2%
of the nominal voltage
Asymmetry 2 to 22%
of the nominal voltage
Tolerance 2 to 22%
of the nominal voltage
Output Specifications
Output 2 x SPDT relays N.E. Rated insulation voltage 250 VAC
Contact ratings (AgSnO2) µ
Resistive loads AC 1 5 A @ 250 VAC DC 12 5 A @ 24 VDC
Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC
Mechanical life ≥ 30 x 106 operations
Electrical life ≥ 105 operations
(at 5 A, 250 V, cos ϕ = 1)
Operating frequency ≤ 7200 operations/h
Dielectric strength
Dielectric voltage ≥ 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs)
Note: The input voltage must not exceed the maximum rated voltage or drop below the minimum rated voltage
reported above.
Hysteresis
Set points from 2 to 5% 1% Set points from 5 to 22% 2%
Specifications are subject to change without notice (12.05.10) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostrado SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltag - CARLO GAEnglish311 Kbytespdf1-mostrado SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltag - CARLO GA
pdf1- SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltag - CARLO English12 Mbytespdf1-mostrado SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltag - CARLO GA
pdf2-mostrado SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltag - CARLO GAEnglish630 Kbytespdf1-mostrado SIZE 36 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Under and over voltag - CARLO GA