CLP4MA2A115 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CLP4MA2A115 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and..

CLP4MA2A115

CLP4MA2A115

CARLO GAVAZZI

Available

Ship on today

Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and Emptying CONNECTION Plug and socket OUTPUT Relay DPDT MATERIAL Plastic Others HOUSING 35,5 x 81 x 63 mm SENSING FUNCTION 250 oHm to 500 koHm MATERIAL NORYL ADDITIONAL Alarm HiHi and LoLo

More details


Level Sensors Detectors Measurement

Sensors

Conductive Level Sensors

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$85.65
3+$81.69
5+$80.25
7+$79.42
10+$78.72
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Conductive Sensors
2 to 4-point level controller
Type CL with potentiometer
• Conductive level controller
• Adjustment of sensitivity – operating resistance from
250Ω to 500KΩ
• Multiple combinations of filling and emptying applications
• Low-voltage AC electrodes
• Easy installation on DIN rails or with 11 pin circular plug
• Rated operational voltage:
24 VAC/DC, 115 VAC or 230 VAC
• Output 2x8A/250 VAC SPDT relay
• LED indication for: Output ON and Power ON
Product Description
Ordering Key
CLD4MA2DM24
µ-Processor based level controller for liquids with a wide sensitivity range (like sewage water, chemicals, salt water etc.). The controller has a separate output for alarm indication in case of a tank
Type Selection
running dry or if an overflow condition occurs.
8A SPDT/SPST relay output, NO/NC.
Sensitivity control by potenti- ometer level in 3 ranges.
Type
DIN rail mounting
Inputs Function Adjustment Outputs
Relay versions
Power supply
Mounting Relay Ordering no. Ordering no. Ordering no.
Supply: 24 VAC/DC Supply: 115 VAC Supply: 230 VAC
DIN-rail SPDT + SPST CLD4MA2DM24 CLD4MA2D115 CLD4MA2D230
11-p circular plug 2 SPST CLP4MA2AM24 CLP4MA2A115 CLP4MA2A230
Specifications
Rated operational voltage (UB)
Pin 2 & 10 230 195 to 265 VAC, 45 to 65 Hz
115 98 to 132 VAC, 45 to 65 Hz
Supply class 2 24 19.2 to 28.8 VAC/DC Rated insulation voltage <2.0 kVAC (rms) Rated impulse withstand
voltage 4 kV (1.2/50 µs) (line/neutral)
Rated operational power
AC supply 5 VA AC/DC supply 5 VA / 5 W
Delay on operate (tV) < 300 mS
Outputs Make or break on rotary-switch
Rated insulation voltage 250 VAC (rms) (cont./elec.)
Relay Rating (AgCdO) µ (micro gap)
Resistive loads AC1 8 A / 250 VAC (2500 VA) DC1 1 A / 250 VDC (250 W)
or 10 A / 25 VDC (250 W) Small induc. Loads AC15 0,4 A / 250 VAC
DC13 0,4 A / 30 VDC Mechanical life (typical) ≥ 30 x 106 operations
@ 18’000 imp/h
Electrical life (typical) AC1 > 250’000 operations
Level probe supply Max. 5 VAC Level probe current Max. 2 mA Sensitivity 250Ω to 500KΩ
Factory settings standard
range “S” 100KΩ
Ranges L (Low sensitivity) 250 Ω to 5 KΩ, CF* = 4.7 nF Ranges S (Standard sensitivity) 5 KΩ to 100 KΩ, CF* = 2.2 nF
Ranges H (High sensitivity) 50 KΩ to 500 KΩ, CF* = 1.0 nF
Dielectric voltage >2.0 KVAC (rms) (contacts / electronics)
Rated impulse withstand volt. 4 kV (1.2/50 µS) (contacts /
electronics) (IEC 664)
Operating frequency (f)
Relay output 0.5 HZ
Response time
OFF-ON (ton) 1 s
ON-OFF (toff) 1 s
Environment
Overvoltage category III (IEC 60664)
Degree of protection IP 20 (IEC 60529, 60947-1) Pollution degree 2 (IEC 60664/60664A,
60947-1)
Temperature
Operating -20º to +50ºC (-4º to + 122ºF) Storage -50º to +85ºC (-58º to +185ºF)
Housing material CLP NORYL PPO, light grey
CLD ABS VO, light grey
Weight
AC supply 200 g
AC/DC supply 125 g
UL Approvals cURus UL508, UL325, CSA-C22.2
No.247
CE marking Yes
*CF = maximum Cable Capacitance
Specifications are subject to change without notice (13.04.2015) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and E - CARLO GAVAEnglish438 Kbytespdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and E - CARLO GAVA
pdf1-Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and E - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and E - CARLO GAVA
pdf2-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and E - CARLO GAVAEnglish200 Kbytespdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling and E - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or