Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE Power and power factor monitoring Others SIZE 45 mm POWER SUPPLY RANGE 600÷690 VAC MONITORING FUNCTION PF monitoring MOUTING DIN-rail INPUT RANGE 0.1-0.99 DELAY 1, adjustable

More details


Energy Meters Control Analizers

Controls

Monitoring Relays and Measurement Current Transformers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$162.32
2+$158.10
3+$156.01
4+$154.68
5+$153.86
*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Monitoring Relays
3-Phase LoadGuard
Types DWB01, PWB01
DWB01PWB01
• TRMS load guard relays for three phase balanced applications
• Measuring if the power factor is within set limits
• Measure their own power supply
• Measuring ranges: 5A, 10A, MI current transformers
• Power ON delay 1 to 30 s knob adjustable
• Separately adjustable upper/lower level on absolute scale
• Programmable latching or inhibit at set level
• Automatic and manual start and stop of the system
• Output: 8 A SPDT relay N.D. or N.E. selectable
• For mounting on DIN-rail in accordance with DIN/EN
50 022 (DWB01) or plug-in module (PWB01)
• 45 mm Euronorm housing (DWB01) or 36 mm plug-in module (PWB01)
• LED indication for relay, alarm and power supply ON
Product Description
Ordering key
DWB 01 C M48 10A
DWB01 and PWB01 are precise TRMS power factor monitoring relays for 3- phase balanced systems. They can be used for moni- toring the actual load of asynchronous motors and other symmetrical loads, where the power factor is almost proportional to the load.
The relay measures the power factor (cos ϕ), that is the ratio between the active and the apparent power of a motor.
Start/stop input allowsto use a manual switch to start and stop the motor, without the need of an auxiliary device.
The advantage of using the latch function isthat the relay can be kept energized even after the end of the alarm condition. Inhibit func- tion can be used to avoid relay operation when not desired(maintenance, tran- sients).
The LED's indicate the state of the alarm and the output relay.
Housing Function Type
Item number
Output
Power Supply
Range
Type Selection
MountingOutputSupply: Supply:Supply: Supply:
208 to 240 VAC380 to 415 VAC 380 to 480 VAC600 to 690 VAC
DIN-rail SPDT DWB 01 C M23 10A DWB 01 C M48 10A DWB01 C M69 10A
Plug-in SPDT PWB 01 C M23 10A PWB 01 C M48 10A
InputSpecifications
Input
Voltage (Own power supply):
3 - phase DWB01: L1, L2, L3
PWB01: 5, 6, 7
M23: 208 to 240 VAC ± 15% DWB01CM48: 380 to 480 VAC ± 15% PWB01C 8: 380 to 415 VAC ± 15% DWB01CM69: 600 to 690 VAC ± 15%
1- phase DWB01CM23: L1, L2 (connect pins L2, L3) PWB01CM23: 5, 6 (connect pins 6, 7)
208 to 240 VAC ± 15%
Current:DWB01: 5A, 10A: I1, I2
MI...: U1, U2
PWB01: 5A, 10A: 11, 10
MI...: 9, 8
Measuring ranges Upper level Lower level
Power factor (cos ϕ)0.1 to 0.990.1 to 0.99
AACrmsMax. curr. (30 s)
Direct input:0.5 to 5A30A
1 to 10A 50A
Standard CT (examples)
TADK2 50 A/5 A5 to 50 A60 A CTD1 150 A/5 A15 to 150 A180 A CTD4 400 A/5 A40 to 400 A480 A TAD12 1000 A/5 A100 to 1000 A1200 A TACO200 6000 A/5 A600 to 6000 A7200 A
MI CT ranges
MI 100 10 to 100 A325 AAC MI 500 50 to 500 A1000 AAC
Specifications are subject to change without notice (07.06.10)1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL - CARLO GAVAZEnglish217 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL - CARLO GAVAZ
pdf1-Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL - CARLO GAVEnglish12 Mbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL - CARLO GAVAZ
pdf2-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL - CARLO GAVAZEnglish630 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL - CARLO GAVAZ

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review