WM1496AV63DS CARLO GAVAZZI FUNCTION selected parameters Power Analyzers MOUNTING Panel 230VAC INPUT POWER OU.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

WM1496AV63DS CARLO GAVAZZI FUNCTION selected parameters Power Analyzers MOUNTING Panel 230VAC INPUT POWER OU..

WM1496AV63DS

WM1496AV63DS

CARLO GAVAZZI

Available

Ship on today

FUNCTION selected parameters Power Analyzers MOUNTING Panel 230VAC INPUT POWER OUTPUT DIGITAL INPUT TYPE None 3 phase AC connection CT / VT RS485 COMMUNICATION Other RANGE 78V to 250VLL 1/5 (6) ACA DISPLAY 3x3 DGT. VARIABLE kWh, kvarh, W, Wdmd, var, VA, VAdmd, PF, V, A, W, Admd, Hz, Amax, Admd max, max Wdmd PULSE DIGITAL INPUTS nothing nothing nothing virtual analog ALARMS

More details


Energy Meters Control Analizers

Controls

Energy Management, Software and Accessories

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$299.37
2+$292.77
3+$290.63
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Energy Management
Power Analyzer
Type WM14-96 “Basic Version”
• Class 1 (active energy)
• Class 2 (reactive energy)
• Accuracy ±0.5 F.S. (current/voltage)
• Power analyzer
• Display of instantaneous variables: 3x3 digit
• Display of energies: 8+1 digit
• System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz
• Amax, Admd max, Wdmd max indication
• Energy measurements: kWh and kvarh
• Hour counter (5+2 DGT)
• TRMS meas. of distorted sine waves (voltages/currents)
• Power supply: 24V, 48V, 115V, 230V, 50-60Hz 18 to 60VDC
• Optional dual pulse output
• Alarms (visual only) VLN, An
• Optional galvanically insulated measuring inputs
Product Description
• Protection degree (front): IP65
• Front dimensions: 96x96mm
• Optional RS422/485 serial port
How to order WM14-96 AV5 3 D PGX
3-phase power analyzer with built-in programming key- pad. Particularly recom- mended for displaying the main electrical variables. Housing for panel mounting,
(front) protection degree IP65, and optional RS485 serial port or dual pulse out- put. Parameters pro- grammable by means of CptBSoft.
Model Range code System
Power supply
Option
How to order
CptBSoft
Type Selection
CptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables.
Range codes
AV5: 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 V
AV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 V
VL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6A
Input specifications
Rated inputs
System
3 : 1-2-3-phase, balanced/unbalanced load,with or without neutral
Power supply
A: 24VAC
-15+10%, 50-60Hz
B: 48VAC
-15+10%, 50-60Hz
C: 115VAC
-15+10%, 50-60Hz
D: 230VAC
-15+10%, 50-60Hz
3: 18 to 60VDC (not available in case of SG or PG options)
Options
X: None
S: RS485 port
SG: RS485+galvanic insu- lated measurig inputs
PG: Dual pulse output + galvanically insulated measuring inputs.
0.03Ato0.25A:±(2%FS +5DGT)
Current “X-S options” 3 (non insulated each other)
Current “SG-PG options” 3 (insulated each other) Voltage 4
Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%) 1150W-VA-var, FS:230VLN,
400VLL AV6: 285W-VA-var, FS:57VLN, 100VLL
Current 0.25 to 6A: ±(0.5% FS +1DGT)
0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current 0.25 to 6A: ±(1.5% FS +1DGT)
0.09Ato0.25A:±(0.5%FS+7DGT) Phase-phase voltage ±(1.5% FS +1 DGT)
Phase-neutral voltage ±(0.5% FS + 1 DGT)
Active and Apparent power, 0.25 to 6A: ±(1% FS +1DGT)
0.03A to 0.25A: ±(1% FS
+5DGT)
Reactive power 0.25 to 6A: ±(2% FS +1DGT)
Active energy “X-S option” Class 2 (start up “I”: 30mA) Reactive energy “X-S option” Class 3 (start up “I”: 30mA) Active energy “SG-PG opt.” Class 1 (start up “I”: 30mA) Reactive energy “SG-PG opt.” Class 2 (start up “I”: 30mA) Frequency ±0.1Hz (48 to 62Hz)
Additional errors
Humidity ≤0.3% FS, 60% to 90% RH
Temperature drift ≤ 200ppm/°C
Sampling rate 1400 samples/s @ 50Hz
1700 samples/s @ 60Hz
Display refresh time 700ms
Display
Type LED, 14mm
Read-out for instant. var. 3x3 DGT
Read-out for energies 3+3+3 DGT (Max indication:
999 999 99.9)
Specifications are subject to change without notice WM14 96 DS ENG 200508 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoCARLO GAVAZZI - WM1496AV63DSEnglish173 Kbytespdf1-mostradoCARLO GAVAZZI - WM1496AV63DS
pdf1-CARLO GAVAZZI - WM1496AV63DSEnglish12 Mbytespdf1-mostradoCARLO GAVAZZI - WM1496AV63DS

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or