Product successfully added to your shopping cart
1SBL136261R2300
ABB
1
AF09ZB-40-00-23 100-250V50/60HZ-DC Contactor
Low-voltage industrial components > Power contactor, AC switching
Contactors and overload relays > AF contactors to 38 A
* Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Data Sheet, Technical Information: | 1SBC100174C0201 |
Instructions and Manuals: | 1SBC101037M6801 |
Product Net Width: | 45 mm |
Product Net Depth / Length: | 77 mm |
Product Net Height: | 86 mm |
Product Net Weight: | 0.31 kg |
Number of Main Contacts NO: | 4 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 0 |
Rated Operational Voltage: | Main Circuit 690 V |
Rated Frequency (f): | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 25 A (690 V) 60 °C 25 A (690 V) 70 °C 22 A |
Rated Operational Current AC-3 (Ie): | (220 / 230 / 240 V) 60 °C 9 A (380 / 400 V) 60 °C 9 A (415 V) 60 °C 9 A (440 V) 60 °C 9 A (500 V) 60 °C 9.5 A (690 V) 60 °C 7 A |
Rated Operational Power AC-3 (Pe): | (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 1 s -empty- A |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A |
Maximum Electrical Switching Frequency: | AC-1 600 cycles per hour |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V |
Operate Time: | Between Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 ms |
Connecting Capacity Main Circuit: | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible with Ferrule 1/2x 0.75 ... 6 mm² Rigid 1/2x 1 ... 6 mm² |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² |
Wire Stripping Length: | Control Circuit 10 mm Main Circuit 10 mm |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
Terminal Type: | Screw Terminals |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... +70 °C |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
General Use Rating UL/CSA: | (600 V AC) 25 A |
CB Certificate: | CB_SE-80869M1 |
CCC Certificate: | CCC_2010010304445624 |
Declaration of Conformity - CE: | 1SBD250002U1000 |
EAC Certificate: | EAC_RU C-FR ME77 B01010 |
Environmental Information: | 1SBD250167E1000 |
GOST Certificate: | GOST_POCCFR.ME77.B07175.pdf |
Instructions and Manuals: | 1SBC101037M6801 |
KC Certificate: | KC_HW02016-15007A |
RoHS Information: | 1SBD251017E1000 |
UL Certificate: | UL_20120918-E319322-3-1 |
UL Listing Card: | UL_E319322 |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 87 mm |
Package Level 1 Depth / Length: | 79 mm |
Package Level 1 Height: | 47 mm |
Package Level 1 Gross Weight: | 0.31 kg |
Package Level 1 EAN: | 3471523124431 |
Package Level 2 Units: | 54 piece |
Package Level 2 Width: | 250 mm |
Package Level 2 Depth / Length: | 300 mm |
Package Level 2 Height: | 315 mm |
Package Level 2 Gross Weight: | 16.74 kg |
Package Level 3 Units: | 1296 piece |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
UNSPSC: | 39121529 |
Title: | Size: | Type: |
---|---|---|
1SBL136261R2300 1SBL136261R2300 1SBL136261R2300_AF09ZB-40-00-23.pdf | 213 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.