Features
Version as maintenance-/service switch
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
UV resistance only in connection with protective shield.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Rated impulse withstand voltage (Uimp)
Utilization category
DC-21 A
DC-PV (EN 60947-3)
Rated permanent current at AC-21, 400 V
Rated permanent current at AC-23, 400 V
Rated uninterrupted current (Iu)
Application
- Residential buildings
- Utility buildings
Device construction
Complete device in housing
Rated short-time withstand current (Icw)
Electrical connection type of main circuit
Ambient operating temperature - max
Ambient operating temperature - min
Number of auxiliary contacts (change-over contacts)
Number of auxiliary contacts (normally closed contacts)
Rated conditional short-circuit current (Iq)
Degree of protection (front side)
Locking facility
Lockable in the 0 (Off) position (with padlock)
Number of auxiliary contacts (normally open contacts)
Rated operating voltage (Ue) - max
Rated operating voltage (Ue) - min
Rated short-circuit making capacity (Icm)
0.3 kA (up to 440 V, 50/60 Hz)
Rated operational current (Ie) at DC-21A
Rated operational power at AC-23A, 400 V, 50 Hz
Rated operational power at AC-3, 380/400 V, 50 Hz