Softstarter, 55 A, 200 - 480 V AC, Us= 110 - 230 V AC, Grandezza FS3

DS7 Soft Starter 55A 200-480V AC us=110/230V AC

Eaton DS7 Soft starter, 55 A, 200 - 480 V AC, Us= 110 - 230 V AC, Frame size FS3

Soft starter, Descrizione: Con contatti di derivazione interni, Funzione: Avviatori statici per carichi trifase, Tensione di alimentazione di rete (50/60 Hz): ULN= 200 - 480 V AC, Tensione di alimentazione: Us= 110 - 230 V AC, Tensione di controllo: UC= 110 - 230 V AC, Potenza nominale del motore assegnata (standard, collegamento in linea) a 400 V, 50 Hz: P= 30 kW, a 460 V, 60 Hz: P= 40 HP, Corrente nominale di impiego AC-53: Ie= 55 A, Tensione nominale di esercizio: EU= 200 V, 230 V, 400 V, 480 V, Collegamento a SmartWire-DT: no, Dimensioni del telaio: FS3, Norme: IEC/EN 60947-4-2, UL 508, CSA22.2-14

Maggiori dettagli


apparecchi elettrici a bassa tensione > starter progressivo

Soft Starter standard

* Prodotto nuovo nel suo imballaggio d'origine con tutte le garanzie e certificazioni de EATON-MOELLER

Prezzo totale: $734.83
Prezzo unitario: $734.83

Quantità Prezzo
1+$734.83
2+$713.52
*Questo prezzo è per unità e mostra il valore netto ( escluse le imposte indirette se applicabile ).

Se il nostro prezzo non è il migliore, chiedici un preventivo Richiedi un preventivo

Più venduti

Dettagli



General specifications

Product Name
Eaton DS7 Soft starter
Catalog Number
134935
EAN
4015081317509
Product Length/Depth
139 mm
Product Height
175 mm
Product Width
93 mm
Product Weight
1.8 kg
Certifications
UkrSEPRO
CSA22.2-14
C-Tick
CSA Class No.: 321106
CSA-C22.2 No 0-M91
CSA
CE
GB 14048.6
UL 508
CSA-C22.2 No 14-05
UL
IEC/EN 60947-4-2
CSA File No.: 2511305
UL File No.: E251034
Model Code
DS7-342SX055N0-N

Modelli & caratteristiche

Fitted with:
Internal bypass
Internal bypass contacts
Functions
Single direction
Suppression of closing transients
Suppression of DC components for motors
Min. ramp time 1 s - fast switching (semiconductor contactor)
Soft start function
Potential isolation between power and control sections

Informazioni generali

Class
Other
Connection to SmartWire-DT
No
Degree of protection
IP20
NEMA 1
Frame size
FS3
Mains voltage - max
480 V
Mains voltage - min
200 V
Overvoltage category
II
Pollution degree
2
Radio interference class
Class A (EN 55011)
Suitable for
Branch circuits, (UL/CSA)
Type
Soft starter for three-phase loads
Voltage type
AC

Condizioni meccaniche ambientali

Mounting position
Vertical
Shock resistance
8 g, 11 ms, Mechanical
Vibration resistance
2M2 to EN 60721-3-2

Condizioni ambientali e climatiche

Altitude
Max. 2000 m
Above 1000 m with 1 % derating per 100 m
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-5 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-3

Parti conduttive principali

Overload cycle
AC-53a: 3 - 5: 75 - 10
Rated operational current (Ie) at AC-53
55 A
Rated operational voltage (Ue) - max
480 V
Rated operational voltage (Ue) - min
230 V
Short-circuit protection rating
3 x 170M3013, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
NZMN1-M63/PKZM4-57, Type “1” coordination, Main conducting paths
Supply frequency
50/60 Hz, fLN, Main circuit
Voltage rating - max
480 V

Potenza nominale d'impiego (Motore)

Assigned motor power at 200/208 V, 60 Hz, 3-phase
15 HP
Assigned motor power at 220/230 V, 60 Hz, 3-phase
20 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
40 HP
Rated operational power at 220/230 V, 50 Hz
15 kW
Rated operational power at 400 V, 50 Hz
30 kW

Sezioni di collegamento

Terminal capacity (copper band)
9 x 9 x 0.8 mm, Main cables
2 x 9 x 0.8 mm, Main cables
Terminal capacity (flexible with ferrule)
2 x (0.5 - 0.75) mm², Control circuit cables
1 x (0.5 - 1.5) mm², Control circuit cables
Terminal capacity (solid)
1 x (25 - 70) mm², Main cables
1 x (0.5 - 2.5) mm², Control circuit cables
2 x (6 - 25) mm², Main cables
2 x (0.5 - 1.0) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)
1 x (21 - 14), Control circuit cables
1 x (12 - 2/0), Main cables
2 x (21 - 18), Control circuit cables
Terminal capacity (stranded)
1 x (25 - 70) mm², Main cables
1 x (0.5 - 1.5) mm², Control circuit cables
2 x (6 - 25) mm², Main cables
2 x (0.5 - 1.0) mm², Control circuit cables
Screwdriver size
0.6 x 3.5 mm, Terminal screws, Control circuit cables
PZ2, 1 x 6 mm, Terminal screw, Standard screwdriver
Tightening torque
6 Nm (≤ 10 mm²)
0.4 Nm, Screw terminals, Control circuit cables
9 Nm (> 10 mm²)

Circuito di comando

Current consumption
50 mA, Control circuit, Regulator supply
1.6 mA, Control circuit, Digital inputs, External 24 V
0,6 A/50 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
Drop-out time
350 ms, Control circuit, Digital Inputs, AC operated
Drop-out voltage
AC operated: 0 - 15 V, AC operated
Rated control supply voltage (Us) at AC, 50 Hz - min
110 V
Rated control supply voltage (Us) at AC, 50 Hz - min
110 V
Rated control supply voltage (Us) at AC, 60 Hz - max
230 V
Rated control supply voltage (Us) at AC, 60 Hz - min
110 V
Rated control supply voltage (Us) at DC - max
0 V
Rated control supply voltage (Us) at DC - min
0 V

Ingresso/uscita

Input current
4 mA (at 230 V AC, Digital inputs)
Number of outputs
2 Relay Outputs (TOR, Ready)
Output voltage
250 V AC (relay outputs)
Protection
Finger and back-of-hand proof, Protection against direct contact
Rated control voltage (Uc)
110 - 230 V AC
110 - 230 V AC (-15 %/+10 %)
Rated operational current (Ie) at AC-11
1 A

Funzione soft start

Application
Delay time
0 - 30 s, Soft start function, Ramp times
Ramp/run-up time
1 - 30 s
Start voltage
Min. 30 %, Soft start function, Start voltage = turn-off voltage
Max. 100 %, Soft start function, Start voltage = turn-off voltage

Verifica di progetto

Equipment heat dissipation, current-dependent Pvid
10 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
55 A
Static heat dissipation, non-current-dependent Pvs
10 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 134935 Apparecchi elettrici a bassa tensione (EC000640)
Caratteristica Valore
corrente d'esercizio nominale Ie a 40°C Tu (EF007039) 55 A
tensione d'esercizio nominale Ue (EF002418) 230 V
potenza nominale motore trifase, circuito standard, a 230 V (EF007053) 15 kW
potenza nominale motore trifase, circuito standard, a 400 V (EF007054) 30 kW
potenza nominale motore trifase, circuito a radice di 3, a 230 V (EF007055) 0 kW
potenza nominale motore trifase, circuito a radice di 3, a 400 V (EF007056) 0 kW
funzione (EF000030) senso di rotazione unico
cavallottamento interno (EF009214)
con display (EF000458) No
controllo della coppia (EF009215) No
temperatura ambiente nominale senza derating (EF007074) 40 °C
tensione di alimentazione pilota nominale AC 50 Hz (EF003978) 110 V
tensione di alimentazione pilota nominale AC 60 Hz (EF003979) 110 V
tensione di alimentazione pilota nominale DC (EF003980) 0 V
tipo di tensione per l'azionamento (EF008242) AC
protezione integrata contro il sovraccarico del motore (EF007297) No
classe di intervento (EF006668) altro
grado di protezione (IP) (EF005474) IP20
indice di protezione (NEMA) (EF011959) 1

Datasheet - PDF

Recensioni: (0)

Nessun commento per il momento.

Inserisci recensione
nascondi form
Valutazione:
Nome:
Email:
Titolo:
Testo:
  Captcha
  Inserisci recensione

Tutti i feedback che riceviamo dagli elementi che offriamo sono reali e verificati. Un piccolo gesto, ma di grande valore. Quindi grazie per quel minuto si spende in noi lasciare il vostro parere e punteggio sui prodotti, perché ci aiuta a continuare a migliorare e di offrire ancora maggiore qualità del servizio.