Appearance | I/O Points | I/O | Mounted Connector model | Cable Connector model | Order code 2 Only DIN Track mounting modelsare described here. Refer to the XW2R-series Connector-TerminalBlock Conversion Units Catalog (Cat. No. G077) for information onscrew mounting models. |
---|---|---|---|---|---|
8 Points | Input | XG4A-1431 (MIL Connector) XN2D-4471 (e-CON Connector) | XG4M-1430-T (MIL Connector) XN2A-1470 (e-CON Connector) | XW2R-N08GD-COM |
Appearance | Number of poles | Description | Order code |
---|---|---|---|
4 | For Sensor | XN2A-1470 | |
4 | Relay Connector | XN2B-1470 |
Appearance 2 The mounted Connector shown inthe appearance illustration is a MIL Connector. | Mounted Connector model | Number of poles | Dimension A (mm) | Order code 2 Only DIN Track mounting modelsare described here. Refer to the XW2R-series Connector-TerminalBlock Conversion Units Catalog (Cat. No. G077) for information onscrew mounting models. | |
---|---|---|---|---|---|
MIL Connector | XG4A-2031 | 20 | 81.7 | XW2R-J20GD-T | |
XG4A-3431 | 34 | 130.7 | XW2R-J34GD-T | ||
XG4A-4031 | 40 | 151.7 | XW2R-J40GD-T | ||
XG4A-5031 | 50 | 186.7 | XW2R-J50GD-T | ||
XG4A-6031 | 60 | 221.7 | XW2R-J60GD-T | ||
FCN Connector | FCN-364P040-AU | 40 | 151.7 | XW2R-J40FD-T |
Appearance 2 The mounted Connector shown inthe appearance illustration is a MIL Connector. | Mounted Connector model | Number of poles | Dimension A (mm) | Order code 2 Only DIN Track mounting modelsare described here. Refer to the XW2R-series Connector-TerminalBlock Conversion Units Catalog (Cat. No. G077) for information onscrew mounting models. | |
---|---|---|---|---|---|
MIL Connector | XG4A-2031 | 20 | 64.4 | XW2R-E20GD-T | |
XG4A-3431 | 34 | 98.5 | XW2R-E34GD-T | ||
XG4A-4031 | 40 | 113.5 | XW2R-E40GD-T | ||
XG4A-5031 | 50 | 138.5 | XW2R-E50GD-T | ||
XG4A-6031 | 60 | 163.5 | XW2R-E60GD-T | ||
FCN Connector | FCN-364P040-AU | 40 | 113.5 | XW2R-E40FD-T |
Appearance 2 The mounted Connector shown inthe appearance illustration is a MIL Connector. | Mounted Connector model | Number of poles | Dimension A (mm) | Order code 2 Only DIN Track mounting modelsare described here. Refer to the XW2R-series Connector-TerminalBlock Conversion Units Catalog (Cat. No. G077) for information onscrew mounting models. | |
---|---|---|---|---|---|
MIL Connector | XG4A-2031 | 20 | 64.4 | XW2R-P20GD-T | |
XG4A-3431 | 34 | 98.5 | XW2R-P34GD-T | ||
XG4A-4031 | 40 | 113.5 | XW2R-P40GD-T | ||
XG4A-5031 | 50 | 138.5 | XW2R-P50GD-T | ||
XG4A-6031 | 60 | 163.5 | XW2R-P60GD-T | ||
FCN Connector | FCN-364P040-AU | 40 | 113.5 | XW2R-P40FD-T |
Item | XW2R-N⬜ | XN2⬜ | XW2R-J⬜ | XW2R-E⬜ | XW2R-P⬜ | |
---|---|---|---|---|---|---|
Rated current | Power supply terminal block: 2 A, Connectors/e-CON Connectors: 1 A (However, rated current of e-CON Connector depends on the wires that are used.) | 3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires), 1 A/pin (with AWG24 wires), 0.5 A/pin (with AWG26 or AWG28 wires) | 1 A | |||
Rated voltage | 24 VDC | 32 VDC | 125 VAC, 24 VDC | |||
Contact resistance | – | 30 mΩ max. (at 20 mV, 100 mA max.) | – | |||
Insurationresistance | 100 MΩ min. (at 500VDC) | 103MΩ min. (at 500 VDC) | 100 MΩ min. (at 500 VDC) | |||
Dielectricstrength | 500 VAC for 1 min (leakage current: 1 mA max.) | 1,000 VAC for 60 sec (leakage current: 1 mA max.) | 500 VAC for 1 min (leakage current: 1 mA max.) | |||
Insertiondurability | – | 50 times | – | |||
Ambient operating temperature | 0 to 55°C | –30 to 75°C 2 The operating temperature rangeis restricted by the maximum operating temperature of the cable. | 0 to 55°C | |||
Applicable wires | Applicable wire sizes 2 This is the applicable range for the Power supply terminals. | AWG 24 to 14 (ferrules), AWG 28 to 14 (stranded wires), AWG 28 to 16 (solid wires) (Outer diameter of insulation must be 4 mm max) | Stranded wire 0.08 mm 2 (AWG28) to 0.5 mm 2 (AWG20) (Outer diameter of insulation must be 1.5 mm max) | AWG 22 to 16 (round or forked crimp terminals) AWG 26 to 16 (stranded or solid wires) | AWG 22 to 16 (ferrules) AWG 26 to 16 (stranded or solid wires) | AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) |
Stripped length | AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm | – | 9 mm | 7 mm | AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm | |
Tightening | – | 0.5 N·m | 0.5 to 0.6 N·m | – |
Aucun commentaire sur le produit encore.
Score: | |
Nom: | |
Email: | |
Titre: | |
Commentaire: | |
Recommandez-vous acheter ce produit? | |
Écrire commentaire |
Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.