ANUNCIAR
XN-B4T-SBBC 140135 Y7-140135 EATON ELECTRIC bloc module de base XI / ON, ressort de tension, 4 niveaux de co.. Agrandir l'image
Les images sont à titre illustratif. Svp, révisez la fiche technique.

XN-B4T-SBBC 140135 Y7-140135 EATON ELECTRIC bloc module de base XI / ON, ressort de tension, 4 niveaux de co..

XN-B4T-SBBC

140135

Y7-140135

EATON-MOELLER

bloc module de base XI / ON, ressort de tension, 4 niveaux de connexion, contre. rail Interruptoral C

XN-B4T-SBBC

Eaton XN Base module block XI/ON, tension spring, 4 connection levels, con. to C rail

Rack, Modules de base de bloc XI/ON, Niveaux de raccordement : 4 niveaux de raccordement, Technique de raccordement : Bornes à ressort, Pour module de bloc, Raccordement au rail C, Degré de protection : IP20, Pour utilisation avec : XN-16DI-24VDC-P, Normes : EN 61000-6-2, EN 61000-6-4, EN 61131-2

Plus de détails


Commande industrielle API > Bus de terrain, périphérie déc. - rack

XION Remote Modules d'E / S

Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par EATON-MOELLER

Prix total: $175.81
Prix unitaire: $175.81
Ce prix est par unité et montre la valeur nette (excluant les taxes indirectes le cas échéant) .

Si notre prix n'est pas le meilleur, demandez-nous un devis. Demander un devis

Related products

Les plus vendus

En savoir plus



Spécifications générales

Product Name
Eaton XN Rack
Catalog Number
140135
Model Code
XN-B4T-SBBC
EAN
7640130120464
Product Length/Depth
128.9 mm
Product Height
49.9 mm
Product Width
100.8 mm
Product Weight
0.234 kg
Certifications
UL 508
Certified by UL for use in Canada
CE, cUL
IEC/EN 61131-2
CSA Class No.: 2252-01, 2252-81
UL Recognized
UL Category Control No.: NRAQ, NRAQ7
CSA-C22.2 No. 142
IEC/EN 61000-6-2
Rated data for terminations according to IEC/EN 60947-7-1
CE
UL report applies to both US and Canada
IEC/EN 61000-6-4
IEC/EN 6113-2
UL File No.: E205091

Features & Functions

Fitted with:
Pluggable modules, digital I/O
Pluggable modules, central modules

General

Degree of protection
IP20
Mounting method
Rail mounting possible
Number of connection levels
4
Type
XI/ON block base module
Used with
XN-16DI-24VDC-P
Voltage type
DC

Ambient conditions, mechanical

Drop and topple
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Shock resistance
Mechanical, According to IEC/EN 60068-2-27
Continuous according to IEC/EN 60068-2-29
Vibration resistance
According to IEC/EN 60068-2-6

Climatic environmental conditions

Ambient operating temperature - min
0 °C
Ambient operating temperature - max
55 °C
Environmental conditions
Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation)
Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation)
Relative humidity
5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)

Electro magnetic compatibility

Air discharge
Air/contact discharge according to IEC/EN 61000-4-2
Burst impulse
According to IEC/EN 61000-4-4
Electromagnetic fields
According to IEC EN 61100-4-2
Emitted interference
30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3)
230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3)
Radiated RFI
IEC/EN 61100-4-6
Surge rating
According to IEC/EN 61000-4-5 Level 4
Voltage dips
According to EN 61131-2 (Voltage fluctuations/voltage dips)

Terminal capacities

Terminal capacity
0.5 - 2.5 mm², solid, H07V-U
0.5 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.5 - 1.5 mm², flexible without ferrule, H07V-K
0.5 - 1.5 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Gauge pin
A1 (according to IEC/EN 60947-1)
Stripping length (main cable)
8 mm

Communication

Connection
Connection to C rail
Connection type
Spring-loaded/screw terminal, Connection design in TOP direction
Number of slots
1

Input/Output

Input current at AC - max
0 A
Input voltage at AC 50 Hz - min
0 V
Input voltage at AC 50 Hz - max
0 V
Input voltage at DC - min
0 V
Input voltage at DC - max
0 V
Output current at AC, 50 Hz - max
0 A
Output voltage at AC 50 Hz - max
0 V
Output voltage at DC - min
0 V
Output voltage at DC - max
0 V

Safety

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Through optocoupler: yes

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 140135 Commande industrielle API (EC001598)
Caractéristique Valeur
Avec alimentation intégrée (EF003338) Non
Tension d'entrée CA 50 Hz (EF007118) 0 V
Tension d'entrée CA 60 Hz (EF007119) 0 V
Tension d'entrée CC (EF007120) 0 V
Type de tension d'entrée (EF003033) CC
Courant d'entrée max. à CA 50 Hz (EF007360) 0 A
Courant d'entrée max. à CA 60 Hz (EF007361) 0 A
Courant d'entrée max. CC (EF007362) 0 A
Tension de sortie CA 50 Hz (EF006999) 0 V
Tension de sortie CA 60 Hz (EF007000) 0 V
Tension de sortie CC (EF007001) 0 V
Type de tension de sortie (EF008222) CC
Courant de sortie max. à CA 50 Hz (EF007351) 0 A
Courant de sortie max. à CA 60 Hz (EF007352) 0 A
Courant de sortie max. CC (EF007353) 0 A
Composants système (EF004118) Oui
Nombre de postes d'enfichage (EF003077) 1
Avec modules enfichables, E/S numérique (EF003078) Oui
Avec modules enfichables, E/S analogique (EF003079) Non
Avec modules enfichables, modules de communication (EF003080) Non
Avec modules enfichables, modules de fonction et de technologie (EF003081) Non
Avec modules enfichables, modules centraux (EF003082) Oui
Avec modules enfichables, autres (EF003083) Non
Montage possible sur barres profilées (EF003972) Oui
Montage mural/direct possible (EF007020) Non
Encastrement frontal possible (EF007016) Non
Montage sur rack possible (EF007018) Non
Adapté aux fonctions de sécurité (EF001597) Non
SIL conformément à IEC 61508 (EF009889) Sans
Niveau de performance selon EN ISO 13849-1 (EF007399) Sans
Matériel associé (Ex ia) (EF004141) Non
Matériel associé (Ex ib) (EF004142) Non
Catégorie de protection contre les explosions pour le gaz (EF003997) Sans
Catégorie de protection contre les explosions pour la poussière (EF003998) Sans
Largeur (EF000008) 100.8 mm
Hauteur (EF000040) 49.9 mm
Profondeur (EF000049) 128.9 mm

Datasheet - PDF

Commentaires: (0)

Aucun commentaire sur le produit encore.

Écrire commentaire
Sous forme de peau
Score:
Nom:
Email:
Titre:
Commentaire:
  Captcha
  Écrire commentaire

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.