DANFOSS DRIVES 175U0311 175U0311 MCC103A44K0T5L1670E00TB - Image 1

Les images sont à titre illustratif. Svp, révisez la fiche technique.

175U0311 MCC103A44K0T5L1670E00TB DANFOSS DRIVES MCC103A44K0T5L1670E00TB

Référence: 175U0311

Numéro de catalogue: MCC103A44K0T5L1670E00TB

Fabricant: DANFOSS DRIVES

Description:

MCC103A44K0T5L1670E00TB
VLT® Line reactor MCC 103 - line reactor for load sharing MCC 103 line reactor is specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive in applications using load sharing. Use the MCC 103 line reactor for up to 500V mains supply with 50 Hz or 60 Hz mains frequency. The MCC 103 line reactor is available with IP00 enclosure protection.Specifications:Rated voltage: 380-500 VRated frequency: 50-60 HzRated current 44 AInductance L: 167 uHWinding resistance: 5.4 mOhmL tolerance: ±10%Mains connection - type: Screw terminalMains connection - dimension: 35 mm2Mains connection - tightening torque: 4.0-5.

Catégories:

  • DANFOSS DRIVES > OPTIONS ET ACCESSOIRES FC302 FC202 FC102 - DANFOSS DRIVES

Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par DANFOSS DRIVES

  • En savoir plus
  • Commentaires
Garantie, réparation et dévolution.

* Cet article est peut-être obsolète. Si vous êtes intéressé, demandez-nous un devis et nous vous dirons s'il y a des unités disponibles. S'il n'y en a plus, un de nos techniciens recherchera une alternative livrable présentant des caractéristiques similaires.

Demandez un devis et nous vérifierons la disponibilité des unités. Si aucune unité n'est disponible, l'un de nos techniciens recherchera une solution alternative.

DERNIÈRE CONSULTÉS

EN SAVOIR PLUS

VLT® Line reactor MCC 103 - line reactor for load sharing MCC 103 line reactor is specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive in applications using load sharing. Use the MCC 103 line reactor for up to 500V mains supply with 50 Hz or 60 Hz mains frequency. The MCC 103 line reactor is available with IP00 enclosure protection.

Specifications:
Rated voltage: 380-500 V
Rated frequency: 50-60 Hz
Rated current 44 A
Inductance L: 167 uH
Winding resistance: 5.4 mOhm
L tolerance: ±10%
Mains connection - type: Screw terminal
Mains connection - dimension: 35 mm2
Mains connection - tightening torque: 4.0-5.0 Nm
PE connection - type: Screw connection
PE connection - dimension: M5x10
Ambient temperature without derating: -10 to +45 C°
Derating > 45 °C: 2.5%/K
Derating > 1km: 5%/1km
Type of cooling: Cooled by natural convection
Operating conditions: Permanent operation with 100% load
Weight: 3.8 kg
Dimensions - HxWxD: 195x155 x102 mm
Enclosure degree: IP00
Mounting : Vertical or horizontal

Détails du produit

Poids brut3.8 Kilogram
Poids Net3.8 Kilogram
Volume14.72 Liter
Poids brut3.8 Kilogram
Poids Net3.8 Kilogram
Volume14.72 Liter

FICHE TECHNIQUE - PDF

Derniers commentaires de nos clients

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.