ANUNCIAR
DS7-340SX032N0-N 134914 Y7-134914 EATON ELECTRIC Arrancador suave DS7 32A 200-480 V AC us 24 V AC/DC Ver más grande
Las imágenes son sólo a título ilustrativo. Por favor, revise la ficha técnica.

DS7-340SX032N0-N 134914 Y7-134914 EATON ELECTRIC Arrancador suave DS7 32A 200-480 V AC us 24 V AC/DC

DS7-340SX032N0-N

134914

Y7-134914

EATON-MOELLER

Arrancador suave DS7; 32A; 200-480 V AC; us=24 V AC/DC

Eaton DS7 Soft starter, 32 A, 200 - 480 V AC, Us= 24 V AC/DC, Frame size FS2

Arrancador suave, Descripción: Con contactos de derivación internos, Función: Arrancadores suaves para cargas trifásicas, Tensión de alimentación de red (50/60 Hz): ULN= 200 - 480 V AC, Tensión de alimentación: Us= 24 V AC/DC, Tensión de control: UC= 24 V AC, 24 V DC, Potencia nominal asignada al motor (conexión estándar, en línea) a 400 V, 50 Hz: P= 15 kW, a 460 V, 60 Hz: P= 25 HP, Corriente nominal de funcionamiento AC-53: Ie= 32 A, Tensión nominal de funcionamiento: Ue= 200 V, 230 V, 400 V, 480 V, Conexión a SmartWire-DT: no, Tamaño de bastidor: FS2, Normas: IEC/EN 60947-4-2, UL 508, CSA22.2-14

Más detalles


Interruptores de baja tensión > Arrancador progresivo

Arrancadores Suaves Estándar

* Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $355.94
Precio unitario: $355.94

Cantidad Precio
1+$355.94
2+$345.28
*Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton DS7 Soft starter
Catalog Number
134914
EAN
4015081316991
Product Length/Depth
118 mm
Product Height
150 mm
Product Width
45 mm
Product Weight
0.4 kg
Compliances
CE Marked
Certifications
UL 508
CSA Std. C22.2 No. 0-M91
CSA Std. C22.2 No. 14-05
IEC 60947-4-2
EN 60947-4-2
C-Tick
CSA22.2-14
UL File No.: E251034
CSA File No.: 2511305
CSA-C22.2 No 14-05
UL
UkrSEPRO
GB 14048.6
CE
CSA-C22.2 No 0-M91
CSA
IEC/EN 60947-4-2
CSA Class No.: 321106
Model Code
DS7-340SX032N0-N

Features & Functions

Fitted with:
Internal bypass
Internal bypass contacts
Functions
Potential isolation between power and control sections
Suppression of DC components for motors
Soft start function
Single direction
Suppression of closing transients
Min. ramp time 1 s - fast switching (semiconductor contactor)

General

Class
Other
Connection to SmartWire-DT
No
Degree of protection
NEMA 1
IP20
Frame size
FS2
Mains voltage - max
480 V
Mains voltage - min
200 V
Overvoltage category
II
Pollution degree
2
Radio interference class
Class B (EN 55011)
Suitable for
Branch circuits, (UL/CSA)
Type
Soft starter for three-phase loads
Voltage type
AC/DC

Ambient conditions, mechanical

Mounting position
Vertical
Shock resistance
8 g, 11 ms, Mechanical
Vibration resistance
2M2 to EN 60721-3-2

Climatic environmental conditions

Altitude
Above 1000 m with 1 % derating per 100 m
Max. 2000 m
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-5 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-3

Main conducting paths

Overload cycle
AC-53a: 3 - 5: 75 - 10
Rated operational current (Ie) at AC-53
32 A
Rated operational voltage (Ue) - max
480 V
Rated operational voltage (Ue) - min
230 V
Short-circuit protection rating
3 x 170M1366, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
PKM0-32 (+ CL-PKZ0), Type “1” coordination, Main conducting paths
Supply frequency
50/60 Hz, fLN, Main circuit
Voltage rating - max
480 V

Motor rating

Assigned motor power at 200/208 V, 60 Hz, 3-phase
10 HP
Assigned motor power at 220/230 V, 60 Hz, 3-phase
10 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
25 HP
Rated operational power at 220/230 V, 50 Hz
7.5 kW
Rated operational power at 400 V, 50 Hz
15 kW

Terminal capacities

Terminal capacity (flexible with ferrule)
2 x (0.5 - 0.75) mm², Control circuit cables
2 x (0.75 - 10) mm², Main cables
1 x (0.5 - 1.5) mm², Control circuit cables
1 x (0.75 - 16) mm², Main cables
Terminal capacity (solid)
2 x (0.75 - 10) mm², Main cables
1 x (0.5 - 2.5) mm², Control circuit cables
2 x (0.5 - 1.0) mm², Control circuit cables
1 x (0.75 - 16) mm², Main cables
Terminal capacity (solid/stranded AWG)
1 x (21 - 14), Control circuit cables
2 x (21 - 18), Control circuit cables
18 - 6, Main cables
Terminal capacity (stranded)
1 x (0.5 - 1.5) mm², Control circuit cables
1 x 16 mm², Main cables
2 x (0.5 - 1.0) mm², Control circuit cables
Screwdriver size
PZ2, 1 x 6 mm, Terminal screw, Standard screwdriver
0.6 x 3.5 mm, Terminal screws, Control circuit cables
Tightening torque
3.2 Nm
1.2 Nm, Screw terminals, Control circuit cables

Control circuit

Current consumption
50 mA, Control circuit, Regulator supply
1.6 mA, Control circuit, Digital inputs, External 24 V
Drop-out time
350 ms, Control circuit, Digital Inputs, DC operated
Drop-out voltage
AC operated: 0 - 3 V, AC operated
0 - 3 V, DC operated
Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
Rated control supply voltage (Us) at AC, 60 Hz - max
24 V
Rated control supply voltage (Us) at AC, 60 Hz - min
24 V
Rated control supply voltage (Us) at DC - max
24 V
Rated control supply voltage (Us) at DC - min
24 V

Input/Output

Number of outputs
2 Relay Outputs (TOR, Ready)
Output voltage
250 V AC (relay outputs)
Protection
Finger and back-of-hand proof, Protection against direct contact
Rated control voltage (Uc)
24 V AC
24 V DC
24 V DC (-15 %/+10 %)
24 V AC (-15 %/+10 %)
Rated operational current (Ie) at AC-11
1 A

Soft start function

Application
Delay time
0 - 30 s, Soft start function, Ramp times
Ramp/run-up time
1 - 30 s
Start voltage
Min. 30 %, Soft start function, Start voltage = turn-off voltage
Max. 100 %, Soft start function, Start voltage = turn-off voltage

Design verification

Equipment heat dissipation, current-dependent Pvid
1.5 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
32 A
Static heat dissipation, non-current-dependent Pvs
1.5 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 134914 Interruptores de baja tensión (EC000640)
Característica Valor
Corriente de funcionamiento nominal Ie a 40 ºC Tu (EF007039) 32 A
Tensión de funcionamiento nominal Ue (EF002418) 230 V
Potencia nominal motor trifásico, circuito estándar de 230 V (EF007053) 7.5 kW
Potencia nominal motor trifásico, circuito estándar d 400 V (EF007054) 15 kW
Potencia nominal de motor trifásico de raíz 3, de 230 V (EF007055) 0 kW
Potencia nominal de motor trifásico de raíz 3, de 400 V (EF007056) 0 kW
Función (EF000030) Dirección única
Puenteado interno (EF009214)
Con pantalla (EF000458) No
Regulación del par (EF009215) No
Temperatura ambiente nominal sin reducción de potencia (EF007074) 40 °C
Voltaje nominal de suministro piloto piloto para CA 50 Hz (EF003978) 24 V
Voltaje nominal de suministro piloto piloto para CA 60 Hz (EF003979) 24 V
Voltaje nominal de suministro piloto de piloto para CC (EF003980) 24 V
Tipo de tensión de accionamiento (EF008242) CA/CC
Protección contra sobrecargas del motor integrada (EF007297) No
Clase de disparo (EF006668) Otros
Grado de protección (IP) (EF005474) IP20
Grado de protección (NEMA) (EF011959) 1

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.