3RT1035-3AB00 SIEMENS CONTACTOR, AC-3 18.5 KW/400 V, AC 24 V, 50 HZ, 3-POLE, SIZE S2, CAGE CLAMP View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RT1035-3AB00 SIEMENS CONTACTOR, AC-3 18.5 KW/400 V, AC 24 V, 50 HZ, 3-POLE, SIZE S2, CAGE CLAMP

3RT1035-3AB00

SIEMENS

Available Ship on today

CONTACTOR, AC-3 18.5 KW/400 V, AC 24 V, 50 HZ, 3-POLE, SIZE S2, CAGE CLAMP

More details


Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $110.15
Unit price: $110.15

Quantity Price
1+$110.15
2+$106.54
3+$104.81
4+$103.73
5+$103.19
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



product brand nameSIRIUS
Product designationpower contactor
General technical data:
Size of contactorS2
Insulation voltage
● rated value690 V
Degree of pollution3
Surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation
● between coil and main contacts acc. to EN 60947-1400 V
Protection class IP
● on the frontIP00
● of the terminalIP00
Shock resistance
● at rectangular impulse
— at AC10g / 5 ms, 5g / 10 ms
● with sine pulse
— at AC15g / 5 ms, 8g / 10 ms
Mechanical service life (switching cycles)
● of contactor typical10 000 000
● of the contactor with added electronics-compatible auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
Ambient conditions:
Installation altitude at height above sea level maximum2 000 m
Ambient temperature
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
Main circuit:
Number of NO contacts for main contacts3
Number of NC contacts for main contacts0
Operating current
● at AC-1 at 400 V
— at ambient temperature 40 °C rated value60 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value60 A
— up to 690 V at ambient temperature 60 °C rated value55 A
● at AC-3
— at 400 V rated value40 A
— at 690 V rated value24 A
Connectable conductor cross-section in main circuit at AC-1
● at 60 °C minimum permissible16 mm²
● at 40 °C minimum permissible16 mm²
Operating current for approx. 200000 operating cycles at AC-4
● at 400 V rated value18.5 A
● at 690 V rated value12.6 A
Operating current
● at 1 current path at DC-1
— at 24 V rated value55 A
— at 110 V rated value4.5 A
● with 2 current paths in series at DC-1
— at 24 V rated value55 A
— at 110 V rated value25 A
● with 3 current paths in series at DC-1
— at 24 V rated value55 A
— at 110 V rated value55 A
Operating current
● at 1 current path at DC-3 at DC-5
— at 24 V rated value35 A
— at 110 V rated value2.5 A
● with 2 current paths in series at DC-3 at DC-5
— at 110 V rated value25 A
— at 24 V rated value55 A
● with 3 current paths in series at DC-3 at DC-5
— at 110 V rated value55 A
— at 24 V rated value55 A
Operating power
● at AC-1
— at 230 V at 60 °C rated value22 kW
— at 400 V rated value38 kW
— at 690 V rated value66 kW
— at 690 V at 60 °C rated value66 kW
● at AC-2 at 400 V rated value18.5 kW
● at AC-3
— at 230 V rated value11 kW
— at 400 V rated value18.5 kW
— at 500 V rated value22 kW
— at 690 V rated value22 kW
Operating power for approx. 200000 operating cycles at AC-4
● at 400 V rated value9.5 kW
● at 690 V rated value11.4 kW
Thermal short-time current limited to 10 s400 A
Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor2.6 W
No-load switching frequency
● at AC5 000 1/h
Operating frequency
● at AC-1 maximum1 200 1/h
● at AC-2 maximum600 1/h
● at AC-3 maximum1 000 1/h
● at AC-4 maximum300 1/h
Control circuit/ Control:
Type of voltage of the control supply voltageAC
Control supply voltage at AC
● at 50 Hz rated value24 V
Control supply voltage frequency 1 rated value50 Hz
Operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz0.8 ... 1.1
Apparent pick-up power of magnet coil at AC145 V·A
Inductive power factor with closing power of the coil0.79
Apparent holding power of magnet coil at AC12.5 V·A
Inductive power factor with the holding power of the coil0.36
Closing delay
● at AC10 ... 24 ms
Opening delay
● at AC7 ... 20 ms
Arcing time10 ... 15 ms
Auxiliary circuit:
Number of NC contacts
● for auxiliary contacts
— instantaneous contact0
Number of NO contacts
● for auxiliary contacts
— instantaneous contact0
Operating current at AC-12 maximum10 A
Operating current at AC-15
● at 230 V rated value6 A
● at 400 V rated value3 A
Operating current at DC-12
● at 60 V rated value6 A
● at 110 V rated value3 A
● at 220 V rated value1 A
Operating current at DC-13
● at 24 V rated value10 A
● at 60 V rated value2 A
● at 110 V rated value1 A
● at 220 V rated value0.3 A
Contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings:
Contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
Design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 requiredfuse gL/gG: 125 A
— with type of assignment 2 requiredfuse gL/gG: 63 A
● for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Installation/ mounting/ dimensions:
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
● Side-by-side mountingYes
Height112 mm
Width55 mm
Depth115 mm
Required spacing
● for grounded parts
— at the side6 mm
Connections/Terminals:
Type of electrical connection
● for main current circuitscrew-type terminals
● for auxiliary and control current circuitspring-loaded terminals
Type of connectable conductor cross-sections
● for main contacts
— solid2x (0.75 ... 16 mm²)
— stranded2x (0.75 ... 25 mm²)
— single or multi-stranded2x (0,75 ... 16 mm²)
— finely stranded with core end processing2x (0.75 ... 16 mm²)
— finely stranded without core end processing2x (0.75 ... 16 mm²)
● at AWG conductors for main contacts2x (18 ... 2)
Type of connectable conductor cross-sections
● for auxiliary contacts
— solid2x (0.25 ... 2.5 mm²)
— finely stranded with core end processing2x (0.25 ... 1.5 mm²)
— finely stranded without core end processing2x (0.25 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts2x (24 ... 14)

Datasheet - PDF

Reviews (1)

C Marco

04/15/2019
5
Product Review

At first i was nerves about buying parts from oversea, i was expecting them to take forever to arrive. I couldn't have been more wrong. Part arrive right on the estimated arrive date, all parts correct and undamaged. I'm extremely happy with the services provided. The website is user friendly and its easy to order part i require. The one thing i really enjoy is that i can change the currency to my local dollars!!!

 
Página:1
Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.