Surge protection in IP65 housing for the AC and DC side of an inverter for four-string photovoltaic systems up to 1000 V DC, DC connection via SUNCLIX plug/socket, AC connection via QUICKON nut.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Industry Solutions (IS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$609.62
2+$602.48
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height200 mm
Width377 mm
Depth122 mm
Horizontal pitch17 Div.

Ambient conditions

Degree of protectionIP65
IP65
Impact strengthIK08
Ambient conditionsA, B
Ambient temperature (operation)-20 °C ... 60 °C

General

Housing materialPolycarbonate, glass-fiber-reinforced
Cover materialPolycarbonate, transparent
Connector materialPA
Flammability rating according to UL 94V2 (Gehäuse / Deckel)
V0 (Steckverbinder)
Colorlight grey RAL 7035
Standards for cearances and creepage distancesEN 50539-11
DIN VDE 0110-1
IEC 60664-1
IEC 61643-1
Overvoltage categoryIII
Pollution degree2
Protection classII
Mounting typeSurface/Wall mounting
TypeInstallation housing
Surge protection fault messageOptical, remote indicator contact
Direction of action(L+)-PE & (L-)-PE & (L+)-(L-)
3L-N & N-PE

PV protective circuit AC side

Rated voltage Un230 V AC (400 V AC, TT or TNS network)
Rated operating voltage Ue230 V AC (400 V AC)
Rated surge voltage resistance Uimp4 kV
Rated insulation voltage Ui415 V (Three-phase current of active conductors/active conductors)
240 V (AC current of active conductors/ground)
Rated current IN13.1 A AC
Rated frequency fn50 Hz (60 Hz)

PV protective circuit DC side

Open circuit voltage UOCSTC830 V DC (Solar generator)
Rated surge voltage resistance Uimp8 kV
Rated insulation voltage Ui1000 V DC
Short-circuit current ISCSTC4x 8.5 A (per string)

Protective circuit

IEC test classificationPV T1
PV T2
Maximum continuous operating voltage UC (L-N)350 V AC (AC unit)
Maximum continuous operating voltage UC (N-PE)264 V AC (AC unit)
UT (TOV-proof)415 V AC (5 s / L-N)
1200 V AC (200 ms / N-PE)
Nominal frequency fN50 Hz (60 Hz)
Residual current IPE≤ 1 µA (AC)
≤ 20 µA (DC)
Standby power consumption PC≤ 25 mVA (DC)
≤ 3.5 mW (AC)
Max. discharge current Imax (8/20) µs40 kA (DC)
40 kA (AC)
Max. discharge current Imax (8/20) µs maximum (L-N)120 kA (all channels)
Max. discharge current Imax (8/20) µs maximum (N-PE)40 kA
Nominal discharge current In (8/20) µs15 kA (DC)
20 kA (AC)
Nominal discharge current In (8/20) µs (L-N)20 kA (AC)
60 kA (all channels)
Nominal discharge current In (8/20) µs (N-PE)20 kA (AC)
Front of wave sparkover voltage at 6 kV (1.2/50) µs (N-PE)≤ 1.5 kV
Voltage protection level Up (L-N)≤ 1.5 kV
Voltage protection level Up (N-PE)≤ 1.5 kV
Voltage protection level Up (L+) - (L-)≤ 3.5 kV
Voltage protection level Up (L+/L-) - PE≤ 3.5 kV
Residual voltage (L-N)≤ 1.4 kV (at In)
≤ 1.2 kV (at 10 kA)
≤ 1.1 kV (at 5 kA)
≤ 1 kV (at 3 kA)
Residual voltage (L-PE)≤ 1.6 kV (at In)
≤ 1.3 kV (at 10 kA)
≤ 1.2 kV (at 5 kA)
≤ 1.1 kV (at 3 kA)
Residual voltage (N-PE)≤ 0.5 kV (at In)
≤ 0.3 kV (at 10 kA)
≤ 0.25 kV (at 5 kA)
≤ 0.2 kV (at 3 kA)
Residual voltage (L+) - (L-)≤ 3.5 kV
≤ 2.6 kV (at 2 kA)
≤ 2.9 kV (at 5 kA)
Residual voltage (L+/L-) - PE≤ 3.5 kV (at 15 kA)
≤ 2.6 kV (at 2 kA)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Response time tA≤ 25 ns (DC)
Response time tA (L-N)≤ 25 ns
Response time (L-PE)≤ 100 ns
Response time tA (N-PE)≤ 100 ns
Max. backup fuse with branch wiring125 A (gL/gG)
Max. backup fuse with V-type through wiring40 A (gL/gG)
Recommended backup fuse maximumDC, not required
Short-circuit resistance IP with max. backup fuse (effective)25 kA (AC side)
Follow current quenching capacity Ifi (N-PE)100 A

Connection, protective circuit

Cable glandM20
Sealing area5 mm ... 13 mm
Cable glandM25
Sealing area3x 5 mm ... 7 mm

Remote indicator contact

Connection nameRemote fault indicator contact
Switching functionPDT, 1-pos.
Connection methodMC 1,5/3
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.28
Conductor cross section AWG max.16
Maximum operating voltage Umax. AC250 V AC
Maximum operating voltage Umax DC125 V DC
Max. operating current Imax1 A AC (inductive)
1 A AC (ohmic)
30 mA DC (inductive)
200 mA DC (ohmic)

Standards and Regulations

Standards/regulationsIEC 61439-2 2011
EN 61439-2 2011
EN 50539-11 DC surge protection
EN 61643-11 AC surge protection

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2801604-PV-SET 1000DC-SC/AC-3P-QPD English 118 Kbytes PHOENIX CONTACT-2801604-PV-SET 1000DC-SC/AC-3P-QPD

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.