RT 5-NICR/CUNI 3048107 PHOENIX CONTACT Thermoelectric voltage terminal block pair View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RT 5-NICR/CUNI 3048107 PHOENIX CONTACT Thermoelectric voltage terminal block pair

RT 5-NICR/CUNI

3048107

PHOENIX_CONTACT

250

Thermoelectric voltage terminal block pair

More details


Enclosures connectivity

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey 3048107
Packing unit 10 pc
Minimum order quantity250 pc
NoteMade to Order (non-returnable)
GTIN4046356966955
Weight per Piece (excluding packing)85.510 g
Custom tariff number85369010
Country of originCN (China)

General

NoteNote: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories).
Unit pack: 2 pcs.
Number of positions2
Number of levels1
Number of connections4
Potentials2
Nominal cross section1 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition0.56 W
Maximum load current1 A
Nominal current IN1 A
Nominal voltage UN50 mV
Open side panelYes
Shock protection test specificationDIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protectionguaranteed
Finger protectionguaranteed
Result of surge voltage testTest passed
Surge voltage test setpoint9.8 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint2.2 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed
Result of tight fit on supportTest passed
Tight fit on carrierNS 35
Setpoint5 N
Result of voltage-drop testTest passed
Requirements, voltage drop≤ 3.2 mV
Result of temperature-rise testTest passed
Result of thermal testTest passed
Proof of thermal characteristics (needle flame) effective duration30 s
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width32.6 mm
End cover width2.2 mm
Length66 mm
Height NS 35/7,551 mm
Height NS 35/1558.5 mm

Connection data

NoteConnection bolts
Connection methodBolt connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.1 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.1 mm²
Min. AWG conductor cross section, flexible20
Max. AWG conductor cross section, flexible16
Conductor cross section flexible, with ferrule with plastic sleeve min.0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.1 mm²
Cable lug connection according to standardDIN 46234
Min. cross section for cable lug connection0.5 mm²
Max. cross section for cable lug connection1 mm²
Hole diameter, min.5.3 mm
Cable lug width, max.10 mm
Bolt diameter5 mm
Stripping length10 mm
Screw threadM5
Tightening torque, min2.5 Nm
Tightening torque max3 Nm

Standards and Regulations

Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX TERMINAL BLOCKS EN.pdf 69 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.