Product successfully added to your shopping cart
QUINT4-PS/1AC/24DC/20
2904602
PHOENIX_CONTACT
1
Power supply unit
Power Supplies (PS)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2904602 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 207 (C-4-2017) |
GTIN | 4046356985352 |
Weight per Piece (excluding packing) | 1,593.000 g |
Custom tariff number | 85044030 |
Country of origin | TH (Thailand) |
Width | 70 mm |
---|---|
Height | 130 mm |
Depth | 125 mm |
Width with alternative assembly | 122 mm |
Height with alternative assembly | 130 mm |
Depth with alternative assembly | 73 mm |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | ≤ 5000 m (> 2000 m, observe derating) |
Nominal input voltage range | 100 V AC ... 240 V AC |
---|---|
110 V DC ... 250 V DC | |
Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
110 V DC ... 250 V DC -18 % ... +40 % | |
Dielectric strength maximum | 300 V AC 60 s |
AC frequency range | 50 Hz ... 60 Hz -10 % ... +10 % |
Discharge current to PE | < 3.5 mA |
Current consumption | 6.8 A (100 V AC) |
5.5 A (120 V AC) | |
2.8 A (230 V AC) | |
2.7 A (240 V AC) | |
Nominal power consumption | 520 VA |
Inrush surge current | typ. 11 A (at 25 °C) |
Mains buffering | typ. 28 ms (120 V AC) |
typ. 29 ms (230 V AC) | |
Input fuse | 12 A (slow-blow, internal) |
Choice of suitable circuit breakers | 10 A ... 16 A (Characteristic B, C, D, K or comparable) |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor, gas-filled surge arrester |
Nominal output voltage | 24 V DC |
---|---|
Setting range of the output voltage (USet) | 24 V DC ... 29.5 V DC (constant capacity) |
Nominal output current (IN) | 20 A |
Static Boost (IStat.Boost) | 25 A |
Dynamic Boost (IDyn.Boost) | 30 A (5 s) |
Selective Fuse Breaking (ISFB) | 120 A (15 ms) |
Derating | > 60 °C (2.5%/K) |
Connection in parallel | Yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback resistance | ≤ 35 V DC |
Protection against surge voltage on the output | ≤ 32 V DC |
Control deviation | < 0.5 % (Static load change 10 % ... 90 %) |
< 4 % (Dynamic load change 10 % ... 90 %, (10 Hz)) | |
< 0.25 % (change in input voltage ±10 %) | |
Residual ripple | < 50 mVPP(with nominal values) |
Output power | 480 W |
Typical response time | 300 ms (from SLEEP MODE) |
Maximum power dissipation in no-load condition | < 5 W (120 V AC) |
< 5 W (230 V AC) | |
Power loss nominal load max. | < 40 W (120 V AC) |
< 32 W (230 V AC) |
Net weight | 1.3 kg |
---|---|
Efficiency | typ. 92.4 % (120 V AC) |
typ. 94 % (230 V AC) | |
Insulation voltage input/output | 4 kV AC (type test) |
2 kV AC (routine test) | |
Insulation voltage input / PE | 3.5 kV AC (type test) |
2.4 kV AC (routine test) | |
Insulation voltage output / PE | 0.5 kV DC (type test) |
0.5 kV DC (routine test) | |
Protection class | I |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | > 1110000 h (25 °C) |
> 673000 h (40 °C) | |
> 309000 h (60 °C) | |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 30 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 30 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Connection method | Push-in connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Noise emission | Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) |
Noise immunity | Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply) |
Standards/regulations | EN 61000-4-2 |
Contact discharge | 4 kV (Test Level 2) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency range | 1.4 GHz ... 2 GHz |
Test field strength | 3 V/m (Test Level 2) |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-6 |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V (Test Level 3) |
Conducted noise emission | EN 55016 EN 61000-6-4 (Class A) |
Standards/regulations | EN 61000-4-8 |
EN 61000-4-11 | |
EN 61000-4-9 | |
EN 61000-4-12 | |
EN 61000-4-16 | |
EN 61000-4-18 | |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Standard - Safety of transformers | EN 61558-2-16 (air clearances and creepage distances only) |
Standard - Electrical safety | IEC 60950-1/VDE 0805 (SELV) |
Standard - power supply devices for low voltage with DC output | EN 61204-3 |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) |
EN 60204-1 (PELV) | |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Shipbuilding approval | DNV GL, PRS, BV, LR, ABS |
UL approvals | UL Listed UL 508 |
UL/C-UL Recognized UL 60950-1 | |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) |
Approval - requirement of the semiconductor industry with regard to mains voltage dips | SEMI F47-0706; EN 61000-4-11 |
Rail applications | EN 50121-3-2 |
Overvoltage category (EN 60950-1) | II (≤ 5000 m) |
Overvoltage category (EN 61010-1) | II (≤ 5000 m) |
Overvoltage category (EN 62477-1) | III (≤ 2000 m) |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 25; |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.