Key Commercial Data

Orderkey2904602
Packing unit1 pc
Catalog pagePage 207 (C-4-2017)
GTIN4046356985352
Weight per Piece (excluding packing)1,593.000 g
Custom tariff number85044030
Country of originTH (Thailand)

Dimensions

Width70 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly73 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-40 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 5000 m (> 2000 m, observe derating)

Input data

Nominal input voltage range100 V AC ... 240 V AC
110 V DC ... 250 V DC
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
110 V DC ... 250 V DC -18 % ... +40 %
Dielectric strength maximum300 V AC 60 s
AC frequency range50 Hz ... 60 Hz -10 % ... +10 %
Discharge current to PE< 3.5 mA
Current consumption6.8 A (100 V AC)
5.5 A (120 V AC)
2.8 A (230 V AC)
2.7 A (240 V AC)
Nominal power consumption520 VA
Inrush surge currenttyp. 11 A (at 25 °C)
Mains bufferingtyp. 28 ms (120 V AC)
typ. 29 ms (230 V AC)
Input fuse12 A (slow-blow, internal)
Choice of suitable circuit breakers10 A ... 16 A (Characteristic B, C, D, K or comparable)
Type of protectionTransient surge protection
Protective circuit/componentVaristor, gas-filled surge arrester

Output data

Nominal output voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (constant capacity)
Nominal output current (IN)20 A
Static Boost (IStat.Boost)25 A
Dynamic Boost (IDyn.Boost)30 A (5 s)
Selective Fuse Breaking (ISFB)120 A (15 ms)
Derating> 60 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistance≤ 35 V DC
Protection against surge voltage on the output≤ 32 V DC
Control deviation< 0.5 % (Static load change 10 % ... 90 %)
< 4 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.25 % (change in input voltage ±10 %)
Residual ripple< 50 mVPP(with nominal values)
Output power480 W
Typical response time300 ms (from SLEEP MODE)
Maximum power dissipation in no-load condition< 5 W (120 V AC)
< 5 W (230 V AC)
Power loss nominal load max.< 40 W (120 V AC)
< 32 W (230 V AC)

General

Net weight1.3 kg
Efficiencytyp. 92.4 % (120 V AC)
typ. 94 % (230 V AC)
Insulation voltage input/output4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage input / PE3.5 kV AC (type test)
2.4 kV AC (routine test)
Insulation voltage output / PE0.5 kV DC (type test)
0.5 kV DC (routine test)
Protection classI
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 1110000 h (25 °C)
> 673000 h (40 °C)
> 309000 h (60 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.30
Conductor cross section AWG max.10
Stripping length8 mm

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.30
Conductor cross section AWG max.10
Stripping length8 mm

Connection data for signaling

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise immunityImmunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply)
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m (Test Level 2)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
Conducted noise emissionEN 55016 EN 61000-6-4 (Class A)
Standards/regulationsEN 61000-4-8
EN 61000-4-11
EN 61000-4-9
EN 61000-4-12
EN 61000-4-16
EN 61000-4-18
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)
Standard - power supply devices for low voltage with DC outputEN 61204-3
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV)
EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Shipbuilding approvalDNV GL, PRS, BV, LR, ABS
UL approvalsUL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
Approval - requirement of the semiconductor industry with regard to mains voltage dipsSEMI F47-0706; EN 61000-4-11
Rail applicationsEN 50121-3-2
Overvoltage category (EN 60950-1)II (≤ 5000 m)
Overvoltage category (EN 61010-1)II (≤ 5000 m)
Overvoltage category (EN 62477-1)III (≤ 2000 m)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN.pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.