Orderkey | 2702097 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 258 (C-6-2017) |
GTIN | 4046356952491 |
Weight per Piece (excluding packing) | 126.450 g |
Custom tariff number | 85371098 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -35 °C ... 60 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Rated control circuit supply voltage US | 24 V DC -20 % / +25 % |
---|---|
19.2 V DC ... 30 V DC | |
Rated control supply current IS | typ. 60 mA |
Power consumption at US | typ. 1.44 W |
Inrush current | typ. 25 A (Δt = 10 µs at Us) |
Filter time | 10 ms (For the logic. At A1 in the event of voltage dips at Us) |
Protective circuit | Surge protection Suppressor diode |
Protection against polarity reversal for rated control circuit supply voltage |
Input voltage range "0" signal | 0 V DC ... 5 V DC (for safe Off) |
---|---|
Input current range "0" signal | 0 mA ... 2 mA (for safe Off) |
Inrush current | < 11 mA (with Us/Ixto S12/S22) |
< 8.6 mA (with Us/Ixto S34) | |
Current consumption | < 4.1 mA (with Us/Ixto S12/S22) |
< 3.2 mA (with Us/Ixto S34) | |
Filter time | max. 3 ms (at S12, S22, S34; test pulse width) |
min. 21 ms (at S12, S22, S34; test pulse rate) | |
Test pulse rate = 7 x Test pulse width | |
Voltage at input/start and feedback circuit | 24 V DC -20 % / +25 % |
Max. permissible overall conductor resistance | 150 Ω |
Concurrence input 1/2 | ∞ |
Output name | Enabling current path |
---|---|
Output description | safety-related N/O contacts |
Number of outputs | 1 (undelayed) |
1 (delayed) | |
Contact type | 2 enabling current paths |
Contact material | AgSnO2 |
Switching voltage | min. 12 V AC/DC |
max. 250 V AC (Observe the load curve) | |
Limiting continuous current | 6 A (observe derating) |
Inrush current | min. 3 mA |
max. 6 A | |
Sq. Total current | 72 A2(observe derating) |
Switching capacity | min. 60 mW |
Switching frequency | 1 Hz |
Mechanical service life | 10x 106cycles |
Output fuse | 6 A gL/gG (N/O contact) |
4 A gL/gG (for low-demand applications) |
Output description | non-safety-related |
---|---|
Number of outputs | 1 (digital, PNP) |
Voltage | 23 V DC (US- 1 V) |
Current | max. 100 mA |
Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
Short-circuit protection | Yes |
Typical response time at US | < 35 ms (automatic start) |
---|---|
< 30 ms (manual, monitored start) | |
Typical release time at US | < 25 ms (when controlled via S12 (only for undelayed contact 13/14)) |
< 5 ms (when interrupted via A1; applicative deactivation via A1/A2 is not permitted) | |
Delay time range | 0.2 s ... 60 s ±5 % (can be set for 27/28) |
Restart time | < 1 s (Boot time) |
Relay type | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
---|---|
Nominal operating mode | 100% operating factor |
Net weight | 126.45 g |
Mounting position | vertical or horizontal |
Mounting type | DIN rail mounting |
Assembly instructions | See derating curve |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Housing material | PBT |
Housing color | yellow |
Status display | 5 x bi-color LED |
Connection method | Spring-cage connection |
---|---|
pluggable | Yes |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Stop category | 0 |
---|---|
1 | |
Designation | IEC 61508 - High demand |
Safety Integrity Level (SIL) | 3 |
Designation | EN ISO 13849 |
Performance level (PL) | e |
Category | 4 |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 3 |
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178 |
Rated insulation voltage | 250 V AC |
250 V AC | |
Rated surge voltage/insulation | Basic insulation 4 kV: between all current paths and housing Safe isolation, reinforced insulation 6 kV: between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14) between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (27/28) between enabling current paths |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 15g |
Vibration (operation) | 10 Hz ...150 Hz, 2g |
Conformance | CE-compliant |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.