PSM-ME-REP LON485-P 2708041 PHOENIX CONTACT Repeater View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSM-ME-REP LON485-P 2708041 PHOENIX CONTACT Repeater

PSM-ME-REP LON485-P

2708041

PHOENIX_CONTACT

Repeater

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $562.85
Unit price: $562.85

Quantity Price
1+$562.85
2+$515.35
3+$499.70
4+$499.70
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2708041
Packing unit1 pc
GTIN4017918907570
Weight per Piece (excluding packing)188.800 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
CaptionSlim design
Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20
Noise immunityEN 61000-6-2:2005

General

Transmission channels2 (1/1), RxD, TxD, full duplex
Bit distortion< 1.5 % (applies to device: Distortions caused by system-specific cables are not accounted for)
Electrical isolationVCC // RS-485 (A) // RS-485 (B)
Test voltage data interfaces2 kV AC
Test voltage data interface/power supply2 kV AC
2 kV
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 50 081-1
Net weight188.8 g
Housing materialPA
Colorgreen
MTTF1808 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
796 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
334 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
Degree of pollution2
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc (Please follow the special installation instructions in the documentation!)
IECExEx nA IIC T4 Gc
UL, USA/Canada508 recognized
Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X

Power supply

Nominal supply voltage24 V AC/DC ±20 %
Max. current consumption100 mA
Typical current consumption90 mA (24 V DC)

Serial interface

Interface 1RS-485 interface in acc. with EIA/TIA-485, DIN 66259-4
Operating modeSemi-duplex
Connection methodPluggable screw connection
File format/codingManchester, slip-tolerant
Data direction switchingAutomatic control
Transmission medium2-wire twisted pair, shielded
Transmission length≤ 1200 m (depends on transmission speed, bus system and cable type)
Termination resistor120 Ω
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Serial transmission speed39.1/ 78.1/ 500/ 625/ 1000/ 1250/ 2000 kbps
Interface 2RS-485 interface in acc. with EIA/TIA-485, DIN 66259-4
Operating modeSemi-duplex
Connection methodPluggable screw connection
File format/codingManchester, slip-tolerant
Data direction switchingAutomatic control
Transmission medium2-wire twisted pair, shielded
Transmission length≤ 1200 m (depends on transmission speed, bus system and cable type)
Termination resistor120 Ω
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Serial transmission speed39.1/ 78.1/ 500/ 625/ 1000/ 1250/ 2000 kbps

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 50 081-1
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV (Test Level 3)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 3 GHz (Test Level 3)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 2 kV
Standards/regulationsEN 55011
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc
IECExEx nA IIC T4 Gc
UL, USA/Canada508 recognized
Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX AUTOMATION EN.pdf 35 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.