Product successfully added to your shopping cart
PSM-ME-REP LON485-P
2708041
PHOENIX_CONTACT
1
Repeater
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2708041 |
---|---|
Packing unit | 1 pc |
GTIN | 4017918907570 |
Weight per Piece (excluding packing) | 188.800 g |
Custom tariff number | 85176200 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -40 °C ... 70 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Altitude | 5000 m (For restrictions see manufacturer's declaration) |
Degree of protection | IP20 |
Noise immunity | EN 61000-6-2:2005 |
Transmission channels | 2 (1/1), RxD, TxD, full duplex |
---|---|
Bit distortion | < 1.5 % (applies to device: Distortions caused by system-specific cables are not accounted for) |
Electrical isolation | VCC // RS-485 (A) // RS-485 (B) |
Test voltage data interfaces | 2 kV AC |
Test voltage data interface/power supply | 2 kV AC |
2 kV | |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 50 081-1 |
Net weight | 188.8 g |
Housing material | PA |
Color | green |
MTTF | 1808 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
796 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
334 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
Degree of pollution | 2 |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc (Please follow the special installation instructions in the documentation!) |
IECEx | Ex nA IIC T4 Gc |
UL, USA/Canada | 508 recognized |
Class I, Div. 2, Groups A, B, C, D | |
Class I, Zone 2, AEx nA IIC T4 | |
Class I, Zone 2, Ex nA IIC T4 Gc X |
Nominal supply voltage | 24 V AC/DC ±20 % |
---|---|
Max. current consumption | 100 mA |
Typical current consumption | 90 mA (24 V DC) |
Interface 1 | RS-485 interface in acc. with EIA/TIA-485, DIN 66259-4 |
---|---|
Operating mode | Semi-duplex |
Connection method | Pluggable screw connection |
File format/coding | Manchester, slip-tolerant |
Data direction switching | Automatic control |
Transmission medium | 2-wire twisted pair, shielded |
Transmission length | ≤ 1200 m (depends on transmission speed, bus system and cable type) |
Termination resistor | 120 Ω |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Serial transmission speed | 39.1/ 78.1/ 500/ 625/ 1000/ 1250/ 2000 kbps |
Interface 2 | RS-485 interface in acc. with EIA/TIA-485, DIN 66259-4 |
Operating mode | Semi-duplex |
Connection method | Pluggable screw connection |
File format/coding | Manchester, slip-tolerant |
Data direction switching | Automatic control |
Transmission medium | 2-wire twisted pair, shielded |
Transmission length | ≤ 1200 m (depends on transmission speed, bus system and cable type) |
Termination resistor | 120 Ω |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Serial transmission speed | 39.1/ 78.1/ 500/ 625/ 1000/ 1250/ 2000 kbps |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Noise emission | EN 50 081-1 |
Noise immunity | EN 61000-6-2:2005 |
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 3 GHz (Test Level 3) |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | ± 2 kV |
Standards/regulations | EN 55011 |
EN 61000-4-6 | |
Frequency range | 0.15 MHz ... 80 MHz |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc |
IECEx | Ex nA IIC T4 Gc |
UL, USA/Canada | 508 recognized |
Class I, Div. 2, Groups A, B, C, D | |
Class I, Zone 2, AEx nA IIC T4 | |
Class I, Zone 2, Ex nA IIC T4 Gc X | |
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.