UNO-PS/2AC/24DC/90W/C2LPS 2904371 PHOENIX CONTACT Power supply unit View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

UNO-PS/2AC/24DC/90W/C2LPS 2904371 PHOENIX CONTACT Power supply unit

UNO-PS/2AC/24DC/90W/C2LPS

2904371

PHOENIX_CONTACT

Power supply unit

More details


Power Supplies (PS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $156.73
Unit price: $156.73

Quantity Price
1+$156.73
2+$134.43
3+$125.35
4+$125.33
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2904371
Packing unit1 pc
Catalog pagePage 228 (C-4-2017)
GTIN4046356933483
Weight per Piece (excluding packing)352.500 g
Custom tariff number85044030
Country of originPL (Poland)

Dimensions

Width55 mm
Height90 mm
Depth84 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2

Input data

Nominal input voltage range2x 400 V AC ... 500 V AC
Input voltage range2x 264 V AC ... 575 V AC
Current consumption0.55 A (400 V AC)
0.48 A (500 V AC)
Nominal power consumption211.3 VA
Inrush surge current< 30 A (typical)
Mains bufferingtyp. 65 ms (400 V AC)
typ. 100 ms (500 V AC)
Input fuse2 A (slow-blow, internal)
Choice of suitable circuit breakers6 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi)0.48
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage24 V DC ±1 %
Nominal output current (IN)3.75 A
3.38 A (Derating 10 %)
Derating55 °C ... 70 °C (2.5%/K)
Connection in parallelno
Connection in seriesNo
Feedback resistance< 35 V DC
Output overvoltage protection≤ 35 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 50 mVPP(with nominal values)
Output power90 W
Maximum power dissipation in no-load condition< 0.7 W
Power loss nominal load max.< 12 W

General

Net weight0.32 kg
Efficiencytyp. 89 % (400 V AC)
typ. 89 % (480 V AC)
Insulation voltage input/output4 kV AC (type test)
3 kV AC (routine test)
Protection classII (in closed control cabinet)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 828000 h (40 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length8 mm
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length8 mm
Screw threadM3

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-6-3
EN 61000-4-6
Frequency range10 kHz ... 80 MHz
Voltage10 V (Test Level 3)
Standards/regulationsEN 61000-4-11
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Safety of transformersEN 61558-2-16
Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
NEC Class 2 as per UL 1310
UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Approval - requirement of the semiconductor industry with regard to mains voltage dipsEN 61000-4-11
Information technology equipment - safety (CB scheme)CB Scheme

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.