Product successfully added to your shopping cart
ASI QUINT 100-240/4.8 EFD
2736699
PHOENIX_CONTACT
1
Power supply unit
I/O
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2736699 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 232 (C-6-2017) |
GTIN | 4017918959685 |
Weight per Piece (excluding packing) | 900.000 g |
Custom tariff number | 85044030 |
Country of origin | TH (Thailand) |
Width | 70 mm |
---|---|
Height | 145 mm |
Depth | 125 mm |
Width with alternative assembly | 122 mm |
Height with alternative assembly | 145 mm |
Depth with alternative assembly | 73 mm |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | 95 % (at 25 °C, non-condensing) |
Nominal input voltage range | 100 V AC ... 240 V AC |
---|---|
AC frequency range | 45 Hz ... 65 Hz |
Frequency range DC | 0 Hz |
Current consumption | approx. 1.8 A (120 V AC) |
1 A (230 V AC) | |
Nominal power consumption | 144 W |
Inrush surge current | < 15 A (typical) |
Mains buffering | > 60 ms (120 V AC) |
> 100 ms (230 V AC) | |
Input fuse | 5 A (slow-blow, internal) |
Choice of suitable circuit breakers | 6 A ... 16 A (Characteristics B, C, D, K) |
Nominal output voltage | 30.1 V DC ±1.5 % |
---|---|
Nominal output current (IN) | 4.8 A |
Connection in parallel | No |
Connection in series | yes |
Residual ripple | < 30 mVPP |
Output power | 144 W |
Typical response time | < 0.5 s |
Peak switching voltages nominal load | < 50 mVPP |
Maximum power dissipation in no-load condition | 4 W |
Power loss nominal load max. | 16 W |
Net weight | 0.9 kg |
---|---|
Operating voltage display | LED |
Efficiency | > 89 % (for 230 V AC and nominal values) |
Insulation voltage input/output | 4 kV AC (type test) |
2 kV AC (routine test) | |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | > 500000 h |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Connection method | Pluggable spring-cage connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Screw thread | M3 |
Connection method | Spring-cage connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Screw thread | M3 |
Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC |
---|---|
Noise immunity | EN 61000-6-2:2005 |
Connection in acc. with standard | CUL |
Contact discharge | 4 kV (Test Level 2) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m |
Frequency range | 1.4 GHz ... 2 GHz |
Test field strength | 3 V/m |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Standards/regulations | EN 61000-4-6 |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V (Test Level 3) |
Low Voltage Directive | Conformance with LV directive 2006/95/EC |
Standard - Safety of transformers | EN 61558-2-17 |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
DIN VDE 0100-410 | |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
DIN VDE 0106-1010 | |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
UL approvals | UL/C-UL listed UL 508 |
UL/C-UL Recognized UL 60950-1 |
China RoHS | Environmentally Friendly Use Period = 25; |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PHOENIX CONTACT-2736699-ASI QUINT 100-240/4.8 EFD | 124 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.