Hybrid motor starter
INTERFACE Components (IF)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2905138 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 20 (C-5-2017) |
GTIN | 4046356919531 |
Weight per Piece (excluding packing) | 282.700 g |
Custom tariff number | 85371098 |
Country of origin | DE (Germany) |
Rated control circuit supply voltage US | 24 V DC |
---|---|
Control supply voltage range | 19.2 V DC ... 30 V DC |
Rated control supply current IS | 60 mA |
Type of protection | Surge protection |
Reverse polarity protection |
Input name | Enable input |
---|---|
Note | The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration), unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function. |
Rated actuating voltage UC | 24 V DC |
Triggering voltage range | 19.2 V DC ... 30 V DC |
Rated actuating current IC | 7 mA |
Switching threshold | 9.6 V (“0” signal) |
19.2 V (“1” signal) | |
Switching level | < 5 V DC (For EMERGENCY STOP) |
Typical turn-off time | < 30 ms |
Type of protection | Reverse polarity protection |
Output name | AC output |
---|---|
Rated operating voltage Ue | 500 V AC |
Operating voltage range | 42 V AC ... 550 V AC |
Rated operating current Ie | 0.6 A (AC-51) |
0.6 A (AC-53a) | |
Mains frequency | 50/60 Hz |
Load current range | 75 mA ... 600 mA (see to derating) |
Trigger characteristic in acc. with IEC 60947-4-2 | Class 10 |
Cooling time | 20 min. (for auto reset) |
Leakage current | 0 mA |
Type of protection | Surge protection |
Switching frequency | ≤ 2 Hz (Load-dependent) |
---|---|
Mounting position | vertical (horizontal DIN rail, motor output below) |
Mounting type | DIN rail mounting |
Assembly instructions | alignable, for spacing see derating |
Operating mode | 100% operating factor |
Maximum power dissipation | 2.5 W |
Minimum power dissipation | 0.88 W |
Operating voltage display | Green LED |
Status display | Yellow LED |
Indication | Red LED |
Connection name | Control circuits |
---|---|
Connection method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Connection name | Load circuit |
---|---|
Connection method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Ambient temperature (operation) | -5 °C ... 60 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Degree of protection | IP20 |
SCCR | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
---|---|
5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) | |
FLA | 0.6 A (480 V AC) |
Group installation | 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded) |
30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded) | |
Category code | NLDX / NRNT |
Horsepower ratings | - |
Rated insulation voltage | 550 V |
---|---|
Rated surge voltage | 6 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Designation | Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
Insulation | Safe isolation (IEC 60947-1) |
Designation | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
Insulation | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
Designation | Standards/regulations |
---|---|
Standards/regulations | IEC 60947-1 |
EN 60947-4-2 | |
IEC 61508 | |
ISO 13849 | |
ATEX | II (2) G [Ex e] [Ex d] [Ex px] |
II (2) D [Ex t] [Ex p] |
Safety Integrity Level according to IEC 61508 | ≤ 3 (Safe shutdown) |
---|---|
2 (Motor protection) | |
Category acc. to EN ISO 13849 | ≤ 3 (Safe shutdown) |
Performance level according to ISO 13849 | e (Safe shutdown) |
ATEX | II (2) G [Ex e] [Ex d] [Ex px] |
II (2) D [Ex t] [Ex p] | |
EU-type examination certificate | PTB 15 ATEX 3000 |
UL certificate | NLDX.E228652 |
NRNT.E172140 |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2905138-ELR H5-IES-PT/500AC-06-IFS | 127 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.