IBS RL 480 MLR R DIO6/1-LK 2737384 PHOENIX CONTACT Electromechanical reversing load motor starter for INTERB.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IBS RL 480 MLR R DIO6/1-LK 2737384 PHOENIX CONTACT Electromechanical reversing load motor starter for INTERB..

IBS RL 480 MLR R DIO6/1-LK

2737384

PHOENIX_CONTACT

Electromechanical reversing load motor starter for INTERBUS; fiber optic technology with 500 kbaud, inputs (24 V DC), integrated motor protection relay (220 V AC to 480 V AC; 8 A, maximum), sensor connection via 5-pos. M12 female connectors, rugged metal housing, IP67 protection

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Ethernet networks. Switches, routers, and antennas - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Dimensions

Width185.1 mm
Height193 mm
Depth138 mm

Ambient conditions

Ambient temperature (operation)0 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)100 %
Permissible humidity (storage/transport)95 % (non-condensing)
Air pressure (operation)860 hPa ... 1080 hPa (up to 1500 m above mean sea level)
Air pressure (storage/transport)660 hPa ... 1080 hPa (up to 3500 m above mean sea level)
Degree of protectionIP65/IP67

Interfaces

Fieldbus systemINTERBUS
DesignationINTERBUS
Connection methodFiber optics
Transmission speed500 kBit/s

Power supply for module electronics

Supply voltage24 V DC
Supply voltage range18.5 V DC ... 32 V DC (including ripple)
Ripple3.6 Vpp
Current consumptiontyp. 90 mA (plus power supply for sensors)

Mains connection

DesignationMains connection
Connection methodPOWER-COMBICON with silver contacts
Designation connection pointTerminal strip; X11 and X12
Number of positions4
Permissible conductor cross section2.5 mm² ... 4 mm²
Operating voltage230 V AC ... 480 V AC ±10 % (conductor voltage)
Max. current carrying capacity20 A

Motor starter, output

Connection methodPOWER-COMBICON
Number1
Designation connection pointX10
Number of positions8
Pg screw connectionPg16
Operating voltage230 V AC ... 480 V AC
Frequency range50 Hz ... 60 kHz
Nominal current range0.2 A ... 8 A (parameterizable, observe derating)
Utilization categoryOn the basis of AC 3
Switching rate5 cycles per minute, maximum
Motor startup time1 s

Motor monitoring

ParameterizationVia INTERBUS
Overspeed tripping≥ 40 A (after 1 second at Inom > 3.6 A)

Motor starter, brake

Continuous load currentmax. 1 A
Type of contactMechanical relay contact
Connection methodPOWER-COMBICON terminal strips
Connection voltage12 V AC/DC ... 480 V AC/DC

Digital inputs

Input nameDigital inputs
Number of inputs6
Connection methodM12 connector
3, 4-wire
Number of positions5
Input voltage24 V DC (DIN EN 61131-2)
Input voltage range "0" signal0 V ... 5 V
Input voltage range "1" signal11 V ... 30 V
Typical input current per channel5 mA (for US1 = 24 V)
Filter time3 ms
Power supply for sensorsUINI = US1 minus 1 V 50 mA Protected against inductive reverse voltages, electronically protected against short-circuiting

Digital outputs

Number of outputs1
Connection methodM12 connector
Number of positions5
Output current0.5 A
Minimum output voltage with nominal currentUS1 minus 2 V
Type of protectionElectronic short-circuit/overload protection

General

Net weight3800 g
Mounting typeWall mounting
Diagnostics messagesMains failure, phase failure, blown fuse Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Sensor supply failure Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Failure of the actuator supply Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Motor overcurrent Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Output stage cannot be controlled Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Module error during self test Message to the master
Mounting typeOn mounting plate

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2737384-IBS RL 480 MLR R DIO6/1-LK English 106 Kbytes PHOENIX CONTACT-2737384-IBS RL 480 MLR R DIO6/1-LK

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.