Key Commercial Data

Orderkey 2904962
Packing unit 1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 138 (C-5-2017)
GTIN4046356904544
Weight per Piece (excluding packing)196.080 g
Custom tariff number85437090
Country of originDE (Germany)

Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.

Input data

Signal inputRepeater power supply operation
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 21.5 V (20 mA)
> 21 V (23 mA)
Signal inputSignal conditioner operation
Current input signal4 mA ... 20 mA
Voltage drop< 3.9 V (in input isolating amplifier operation)

Output data

Signal outputRepeater power supply operation
Current output signal4 mA ... 20 mA (active)
Load/output load current output< 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Signal outputSignal conditioner operation
Current output signal4 mA ... 20 mA (active)
Load/output load current output< 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)

Power supply

DesignationRepeater power supply operation
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption< 75 mA (24 V DC)
Power dissipation< 1.45 W (24 V DC/ 20 mA)
DesignationSignal conditioner operation
Nominal supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption< 46 mA (24 V DC / 20 mA)
Power dissipation< 1.2 W (24 V DC/ 20 mA)

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Connection methodPush-in connection

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)1.3 ms (for jump 4 mA ... 20 mA, typical)
Status displayGreen LED (PWR supply voltage)
Flammability rating according to UL 94V0
Electromagnetic compatibilityConformance with EMC directive
Housing materialPA 6.6-FR
Coloryellow
DesignationInput/output/power supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationOutput 1/output 2
Electrical isolation1.5 kV AC (50 Hz, 1 min., test voltage)
ConformanceCE-compliant, additionally EN 61326
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
SIL2

Data communication (bypass)

HART functionYes
Protocols supportedHART

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value3 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value3 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value3 %

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
EN 61000-4-4
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Flammability rating according to UL 94V0
ConformanceCE-compliant, additionally EN 61326
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.