NBC-MSY/10,0-94H/MSY SCO 1407494 PHOENIX CONTACT Hybrid cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NBC-MSY/10,0-94H/MSY SCO 1407494 PHOENIX CONTACT Hybrid cable

NBC-MSY/10,0-94H/MSY SCO

1407494

PHOENIX_CONTACT

Hybrid cable

More details


Cables > Data cable

Industrial Field Connectivity (IFC)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey1407494
Packing unit1 pc
Catalog pagePage 409 (C-2-2017)
GTIN4046356777933
Weight per Piece (excluding packing)906.600 g
Custom tariff number85444210
Country of originPL (Poland)

Dimensions

Length of cable10 m

Ambient conditions

Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (M12 connector)

General data

NoteFurther products with variable cable type and variable cable length can be found in the accessories section
Rated current at 40°C6 A (Power)
0.5 A (Data)
Rated voltage48 V AC (Power and data)
50 V DC (Power and data)
Number of positions8
Signal type/categoryEthernet hybrid CAT5 (IEC 11801), 100 Mbps
Standards/regulationsM12 connector IEC 61076-2-113
Contact materialCuZn
Contact carrier materialPP / PA 6 GF
Contact surface materialNi/Au

Characteristics head 1

Head typePlug straight M12 SPEEDCON / IP67
No. of positions (pin connector pattern)8 (4+4)
CodingY (Hybrid)
Colorblack
Material (component)CuZn (Contact)
Ni/Au (Contact surface)
PP (Contact carrier, data)
PA (Contact carrier, power)
TPU, hardly inflammable, self-extinguishing (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Shieldedyes
Insulation resistance≥ 100 MΩ
Insertion/withdrawal cycles≥ 100
Torque0.4 Nm
Ambient temperature (operation)-25 °C ... 90 °C

Characteristics head 2

Head typePlug straight M12 SPEEDCON / IP67
No. of positions (pin connector pattern)8 (4+4)
CodingY (Hybrid)
Colorblack
black
Material (component)CuZn (Contact)
Zinc die-cast, nickel-plated (Screw connection)
Ni/Au (Contact surface)
PP (Contact carrier, data)
PA (Contact carrier, power)
TPU, hardly inflammable, self-extinguishing (Grip)
Shieldedyes
Insulation resistance≥ 100 MΩ
Insertion/withdrawal cycles≥ 100
Torque0.4 Nm
Ambient temperature (operation)-25 °C ... 90 °C

Standards and Regulations

Standard designationM12 connector
Standards/regulationsIEC 61076-2-113

Cable

Cable typeEthernet hybrid
Cable type (abbreviation)94H
UL AWM style20963 (80°C/30 V)
Signal type/categoryEthernet hybrid CAT5 (IEC 11801), 100 Mbps
Cable structure1x4xAWG26+1x4xAWG20
Conductor cross section4x 0.15 mm² (Data)
4x 0.6 mm² (Power)
AWG signal line26
AWG power supply20
Conductor structure signal line19x 0.10 mm
Conductor structure, voltage supply19x 0.20 mm
Core diameter including insulation1.05 mm (Data)
1.4 mm (Power)
Wire colorsWhite/orange, orange, white/green, green, white, blue, brown, black
Overall twist1 star quad and 4 wires with 2 fillers
ShieldingTinned copper braided shield
Optical shield covering85 %
External sheath, colorblack RAL 9005
External cable diameter D7.6 mm ±0.2 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles2000000
Minimum bending radius, drag chain applications10 x D
Traversing path4.5 m
Traversing rate3 m/s
Acceleration3 m/s²
Tensile strength GRP70 N (in accordance with DIN EN 50565-1 for flexible installation)
240 N (in accordance with DIN EN 50565-1 for fixed installation)
Cable weight87 kg/km
Outer sheath, materialPUR
Material conductor insulationPP (Data)
PP (Power)
Conductor materialBare Cu litz wires
Insulation resistance≥ 5 GΩ*km
Loop resistance≤ 280.00 Ω/km (Data)
≤ 34.60 Ω/km (Power)
Working capacitancenom. 50 nF (per kilometer)
Wave impedance100 Ω ±15 Ω (4 MHz ... 100 MHz)
Near end crosstalk attenuation (NEXT)56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Attenuation6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.5 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Shield attenuation≥ 80 dB (30 MHz ... 125 MHz)
Differential impedance100 Ω ±5 % (at 100 MHz)
Nominal voltage, cable≤ 50 V (Peak value, not for high-power applications)
Test voltage Core/Core1500 V (50 Hz, 1 min.)
Test voltage Core/Shield1500 V (50 Hz, 1 min.)
Special propertiesFree of substances which would hinder coating with paint or varnish
Silicone-free
Flame resistancein acc. with UL 1581, section 1061
Halogen-freeaccording to IEC 60754
in accordance with DIN VDE 0472 part 815
Resistance to oilaccording to IEC 60811-2-1
according to VDE 0282 Part 10
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 90 °C (cable, fixed installation)
-30 °C ... 70 °C (cable, flexible installation)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.