Orderkey | 2907259 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 28 (C-4-2017) |
GTIN | 4055626176000 |
Weight per Piece (excluding packing) | 660.000 g |
Custom tariff number | 85363030 |
Country of origin | DE (Germany) |
Degree of protection | IP20 (only when all terminal points are used) |
---|---|
Ambient temperature (operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % ... 95 % |
IEC test classification | I / II |
---|---|
T1 / T2 | |
EN type | T1 / T2 |
IEC power supply system | TN-C |
TT | |
Mode of protection | L-N |
L-PE | |
L-PEN | |
N-PE (4+0) | |
Mounting type | DIN rail: 35 mm |
Color | light grey RAL 7035 |
traffic grey A RAL 7042 | |
Housing material | PA 6.6-FR 20% GF |
PBT-FR | |
Degree of pollution | 2 |
Flammability rating according to UL 94 | V-0 |
Type | DIN rail module, two-section, divisible |
Number of positions | 1 |
Surge protection fault message | Optical, remote indicator contact |
Nominal voltage UN | 400 V AC (TN) |
---|---|
400 V AC (IT) | |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 440 V AC |
Residual current IPE | ≤ 5 µA |
Nominal discharge current In(8/20) µs | 25 kA |
Maximum discharge current Imax(8/20) µs | 50 kA |
Impulse discharge current (10/350) µs, charge | 12.5 As |
Impulse discharge current (10/350) µs, specific energy | 160 kJ/Ω |
Impulse discharge current (10/350) µs, peak value limp | 25 kA |
Follow current interrupt rating Ifi | 50 kA |
Short-circuit current rating ISCCR | 50 kA |
Voltage protection level Up | ≤ 2.5 kV |
Residual voltage Ures | ≤ 2.5 kV (at In) |
Front of wave sparkover voltage at 6 kV (1.2/50) µs | ≤ 2.5 kV |
TOV behavior at UT | 580 V AC (5 s / withstand mode) |
760 V AC (120 min / withstand mode) | |
1640 V AC (200 ms / safe failure mode) | |
Response time tA | ≤ 100 ns |
Switching function | PDT contact |
---|---|
Operating voltage | 12 V AC ... 250 V AC |
125 V DC (200 mA DC) | |
Operating current | 10 mA AC ... 1 A AC |
1 A DC (30 V DC) | |
Connection method | Plug-in/screw connection via COMBICON |
Screw thread | M2 |
Tightening torque | 0.25 Nm |
Stripping length | 7 mm |
Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Connection method | Screw terminal blocks |
---|---|
Screw thread | M5 |
Tightening torque | 4.5 Nm |
Stripping length | 18 mm |
Conductor cross section flexible | 2.5 mm² ... 35 mm² |
Conductor cross section solid | 2.5 mm² ... 35 mm² |
Conductor cross section AWG | 13 ... 2 |
Connection method | Fork-type cable lug |
Conductor cross section flexible | 1.5 mm² ... 16 mm² |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.