AXL F DOR4/2 AC/220DC 1F 2700608 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F DOR4/2 AC/220DC 1F 2700608 PHOENIX CONTACT I/O module

AXL F DOR4/2 AC/220DC 1F

2700608

PHOENIX_CONTACT

I/O module

More details


I/O

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $368.74
Unit price: $368.74

Quantity Price
1+$368.74
2+$339.69
3+$339.69
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2700608
Packing unit1 pc
Catalog pagePage 111 (C-6-2017)
GTIN4046356916486
Weight per Piece (excluding packing)222.000 g
Custom tariff number85389091
Country of originDE (Germany)

Dimensions

Dimensional drawing
Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (max. 6 A/channel for wall mounting on horizontal DIN rail; max. 4 A/channel for any mounting position)
-25 °C ... 50 °C (max. 8 A/channel for wall mounting on horizontal DIN rail; max. 6 A/channel for any mounting position)
-25 °C ... 40 °C (max. 8 A/channel for any mounting position)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
When selecting the cables, please note that in the case of a small conductor cross section and high current, the terminal point temperature may be up to 30 K above the ambient temperature.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight222 g
Note on weight specificationswith connectors and bus base module
Degree of pollution2

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptionmax. 280 mA (all relays pick up)
Power consumptionmax. 1.4 W (all relays pick up)

Digital outputs

Output nameRelay output
Output descriptionRelay N/O contact
Connection methodPush-in connection
Connection technology2-wire
Number of outputs4 (floating contacts)
Maximum inrush currentmax. 15 A (for 4 s)
Nominal output voltage220 V DC
230 V AC
Output currentmax. 8 A (per channel, provide an external fuse)
max. 32 A (per module)
Maximum output current per channel8 A

Relay outputs

Switching currentmax. 8 A AC (cos phi = 1)
For DC see load limit curve, e.g., the following values:
max. 8 A DC (≤ 30 V, ohmic load)
max. 500 mA DC (≤ 110 V, ohmic load)
max. 250 mA DC (220 V DC, ohmic load)
max. 220 mA DC (125 V DC, L/R ≤ 50 ms, applications with UL approval)
max. 110 mA DC (250 V DC, L/R ≤ 50 ms, applications with UL approval)
Switching capacitymax. 2000 VA
For DC see load limit curve, e.g., the following values:
max. 240 W (30 V DC)
max. 55 W (≥ 60 V DC)
max. 25 W (125 V DC, 250 V DC, applications with UL approval)
Contact type4 floating N/O contacts
Switching currentmax. 8 A AC (cos phi = 1)
For DC see load limit curve, e.g., the following values:
max. 8 A DC (≤ 30 V, ohmic load)
max. 500 mA DC (≤ 110 V, ohmic load)
max. 250 mA DC (220 V DC, ohmic load)
max. 220 mA DC (125 V DC, L/R ≤ 50 ms, applications with UL approval)
max. 110 mA DC (250 V DC, L/R ≤ 50 ms, applications with UL approval)
Switching capacitymax. 2000 VA
Switching frequencymax. 6 (per minute)
Release time< 5 ms
Mechanical service life10x 106cycles

Electrical isolation

Test sectionRelay contact / logic 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201)
Relay contact / logic 5 kV Pulse test voltage according to EN 61850/IEC 61850
Contact / functional earth ground 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201)
Contact / functional earth ground 5 kV Pulse test voltage according to EN 61850/IEC 61850
Contact / contact (open contact) 1 kV 50 Hz 1 min.
Contact / contact (adjacent connectors 2.5 kV Pulse test voltage according to EN 61850/IEC 61850

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 20g (contact interruption) / 5g (contact closure)
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Developed according to standardIEC 61850-3 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge
IEC 61850-3 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, 20 V/m up to 1 GHz, 10 V/m up to 3 GHz
IEC 61850-3 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 4 kV
IEC 61850-3 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, ±4 kV (asymmetrical)
IEC 61850-3 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
IEC 61850-3 Immunity to magnetic fields, EN 61000-4-8/IEC 61000-4-8 300 A/m continuous, 1000 A/m for 1 s
IEC 61850-3 Immunity to attenuated oscillating magnetic fields, EN 61000-4-10/IEC 61000-4-10 100 A/m
IEC 61850-3 Immunity to conducted common-mode interference, EN 61000-4-16/IEC 61000-4-16 30 V continuous, 300 V for 1 s
IEC 61850-3 Attenuated oscillating waves, EN 61000-4-18/IEC 61000-4-18 2.5 kV asymmetrical
IEC 61850-3 Radio interference properties EN 55022 Class B

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.