AXL F DOR4/2 AC/220DC 1F 2700608 PHOENIX CONTACT Axioline F digital output module, 4 relay outputs, N/O cont.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F DOR4/2 AC/220DC 1F 2700608 PHOENIX CONTACT Axioline F digital output module, 4 relay outputs, N/O cont..

AXL F DOR4/2 AC/220DC 1F

2700608

PHOENIX_CONTACT

Axioline F digital output module, 4 relay outputs, N/O contacts, for nominal voltages up to 230 V AC and 220 V DC, 2-conductor connection technology (including bus base module and connectors), corresponds to standard IEC 61850-3

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Ethernet networks. Switches, routers, and antennas - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Product description

The module is intended for use within an Axioline F station.

It has four floating relay N/O contacts which are independent of one another.

Low-voltage and extra-low-voltage modules can be used side by side within an Axioline F station.

Dimensions

Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (Max. 6 A/channel for wall mounting on horizontal DIN rail; max. 4 A/channel for any mounting position)
-25 °C ... 50 °C (Max. 8 A/channel for wall mounting on horizontal DIN rail; max. 6 A/channel for any mounting position)
-25 °C ... 40 °C (Max. 8 A/channel for any mounting position)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Net weight222 g
Note on weight specificationswith connectors and bus base module
Mounting typeDIN rail
Pollution degree2

Interfaces

DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s

Axioline potentials

Communications power UBus5 V DC (via bus base module)
Current consumption from UBusmax. 280 mA (all relays pick up)

Digital outputs

Output nameRelay output
Connection methodPush-in connection
2-wire
Number of outputs4
Nominal output voltage220 V DC
Maximum output current per channel8 A
Maximum output current per module32 A (external fuse)

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2700608-AXL F DOR4/2 AC/220DC 1F English 155 Kbytes PHOENIX CONTACT-2700608-AXL F DOR4/2 AC/220DC 1F

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review